R 1EFF : 301-399, 401-499, 1 21-51-00Page 23 1 1 Aug 01/05 1 1 1CES 1
R  The percentage of airflow from the flow control valves is selected by the  
R  FLOW selector pushbutton switch 5HB.  
R  The FLOW selector pushbutton switch, which is located on the AIR COND  
R  panel 30VU, has three positions:  
R  - the NORM position, which sets the flow control valve to 100% of the  
R  normal airflow,  
R  - the LO position, which sets the flow control valve to 80% of the normal  
R  airflow.  
R  NOTE : The LO position can be selected for fuel economy purpose.____  
R  This position must only be selected when there is a reduced number  
R  of passengers in the cabin,  
R  - the HI position, which sets the flow control valve to 120% of the  
R  normal airflow.  
R  NOTE : This position is selected in abnormal hot ambient conditions or to____  
R  clear smoke.  
R  The FLOW selector transmits the selected switch position to the ACSC 1  
R  (Air Conditioning System Controller) and via ARINC interface to the ACSC  
R  2. The ACSC calculates the necessary flow demand. Both ACSC set the flow  
R  control valves in the necessary reference position.  
R  The PACK 1 and/or the PACK 2 pushbutton switches control the related pack  
R  flow control valve to the open or closed position.  
R  The flow control valves close automatically on ground, but not in flight,  
R  if:  
R  - there is an engine start,  
R  - there is an ENGINE FIRE pushbutton switch released,  
R  - there is a compressor overheat,  
R  - there is low bleed pressure,  
R  - the DITCHING pushbutton switch 13HL is in the on position,  
R  - the applicable PACK 1 or PACK 2 pushbutton switch is in the off  
R  position.  
R  
R  B. Differential Pressure Sensor (DPS) (FLow Sensor), , Pack Inlet Pressure  
R  Sensor (PIPS)  
R  The differential pressure sensors 23HB2 (24HB2) measure the pressure  
R  difference of the flow at the venturi body.  
R  The pack inlet pressure sensors 23HB1 (24HB1) measure the pressure  
R  upstream of the venturi.  
R 
R 1EFF : 401-499, 1 21-51-00Page 24 1 1 Aug 01/05 1 1 1CES 1
R R R R R R R R R R R R  C. Mixer Flap Actuator The mixer flap actuator 20HB operates a flap in the cockpit supply port of the mixer. The flap connects the cockpit supply duct to the pack 1 mixer chamber, when both packs are in operation. When pack 1 is switched off, the flap changes the position and connects the cockpit supply duct to the pack 2 mixer chamber. This function makes sure of: - a good flow separation during pack 2 operation, - the supply of a sufficient fresh air quantity to the cockpit with pack 1 off. When the flap in the mixer unit enters the airflow it causes a small airflow diversion into the cockpit duct. This results in an adequate supply of conditioned air to the cockpit. 
 **ON A/C ALL 
 4. Power Supply____________ 
 **ON A/C 001-049, 051-060, 101-102, 
 (Ref. Fig. 004)  
R  **ON A/C 301-399, 
 (Ref. Fig. 004A)  
R  **ON A/C 401-499, 
 (Ref. Fig. 004B)  
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 
 Post SB  21-1121 For A/C 001-049,051-060,101-102, 
 (Ref. Fig. 004C)  
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399, 
 (Ref. Fig. 005) 
R 1EFF : ALL 1 21-51-00Page 25 1 1 Aug 01/05 1 1 1CES 1
 Flow Control and Indication - Electrical Schematic
 Figure 004
R 1EFF : 001-049, 051-060, 101-102, 1 21-51-00Page 26 1 1 Aug 01/05 1 1 1CES 1
 Flow Control and Indication - Electrical Schematic R Figure 004A 
R 1EFF : 301-399, 1 21-51-00Page 27 1 1 Aug 01/05 1 1 1CES 1
 Flow Control and Indication - Electrical Schematic R Figure 004B 
R 1EFF : 401-499, 1 21-51-00Page 28 1 1 Aug 01/05 1 1 1CES 1
 Flow Control and Indication - Electrical Schematic
 