• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-02-24 09:47来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (Ref. Fig. 003) 
R  **ON A/C 051-099, 106-149, 201-299,
 (Ref. Fig. 003A) 
R  **ON A/C 301-399,
 (Ref. Fig. 003B) 
R  **ON A/C 401-499,
R  (Ref. Fig. 003C) 
**ON A/C 001-049, 051-060, 101-102,
 (Ref. Fig. 004) 

R 1EFF : ALL 1 21-51-00Page 45 1 1 Aug 01/05 1 1 1CES 1


 Ozone Filter Figure 009 
R 1EFF : 1 1 1CES  001-049, 101-105, 151-199,  1 111 21-51-00 Page 46 Aug 01/05

 

R  **ON A/C 301-399,
R  (Ref. Fig. 004A) **ON A/C 401-499,
R R  (Ref. Fig. 004B) **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, Post SB 21-1121 For A/C 001-049,051-060,101-102, (Ref. Fig. 004C) **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
R  (Ref. Fig. 005) **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299,
R  (Ref. Fig. 010) **ON A/C 301-399,
R  (Ref. Fig. 010A) **ON A/C 401-499,
 (Ref. Fig. 010B) **ON A/C ALL
 (Ref. Fig. 011) 

R 1EFF : ALL 1 21-51-00Page 47 1 1 Aug 01/05 1 1 1CES 1


 Flow of Air into Pressurized Fuselage
 Figure 010

R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 21-51-00Page 48 1201-299, 1Aug 01/05 1 1 1CES 1


 Flow of Air into Pressurized Fuselage 
R  Figure 010A 
R 1EFF :  301-399,  1  21-51-00 Page 49 
1  1  Aug 01/05
 1  1
 1CES  1

 

 Flow of Air into Pressurized Fuselage 
R  Figure 010B 
R 1EFF :  401-499,  1  21-51-00 Page 50 
1  1  Aug 01/05
 1  1
 1CES  1

 

 APU Flow to Pressurized Fuselage Figure 011
 1EFF : 1 1R 1CES  ALL  1 11 1 21-51-00 Page 51 Aug 01/05

 

 **ON A/C 001-049, 051-060, 101-102,
 A. Flow Control Valve
 (1)
 General Information Each air conditioning pack has a flow control valve which gives variable flow and shut off control. These valves are electro-pneumatically operated. They will open when the PACK 1 (2) pushbutton switches are pushed in (the OFF legends go off) if the conditions which follow exist:

 -the engines are not in a starting sequence,
 -an ENGINE FIRE pushbutton switch is in the normal position (the light in the pushbutton switch is off),
 -
the DITCHING pushbutton switch 13HL is released (the ON legend is off),

 -
the bleed air pressure is more than the minimum pressure needed to open the flow control valves.

 

 (2)
 Normal Operation (packs running on engine bleed supply) When the PACK 1 (2) pushbutton switches 7HB (6HB) are pushed in (the OFF legends go off) the flow control valves open. The crew selects the PACK FLOW selector 5HB to the LO, NORM or HI position.


 -This position selects the flow control reference in the zone controller 8HK to 80%, 100% or 120%.
 -
The zone controller calculates the necessary flow and transmits this value to the pack controllers 7HH (27HH).

 -
The pack controllers then set the flow control valves 11HB (8HB) to


 the demanded position. When the PACK FLOW selector is set to the LO position, and the temperature demand cannot be reached, the zone controller will increase the normal airflow of the flow control valve from 80% to 100%.
 (3) APU in Operation (packs running on APU bleed air supply) When the PACK 1 (2) pushbutton switches 7HB (6HB) are pushed in (the OFF legends go off) the flow control valves open. The zone controller 8HK receives the APU bleed valve open signal. The flow control reference in the zone controller is set to 120% and the flow control valves are commanded to the fully open position.
R 1EFF : 001-049, 051-060, 101-102, 1 21-51-00Page 52 1 1 Aug 01/05 1 1 1CES 1


 (4)
 Single Pack Operation (pack running on engine or APU bleed air supply) When a pack pushbutton switch is pushed in (the OFF legend goes off) the respective flow control valve opens. Irrespective of which position the PACK FLOW selector is set to, the zone controller and the pack controller will modulate the pack to the 120% (HI) mode. Thus the flow control valve is commanded to the fully open position.

 (5)
 Operation with Failures

 (a)
 Single Pack Failure When the PACK FLOW selector is set to the NORM or LO position and there is a failure in one pack, the zone controller and the pack controllers modulate the other pack to the 120% (HI) mode. Thus the flow control valve is commanded to the fully open position.

 (b)
 Engine Fire If there is an engine fire, and you push the applicable FIRE pushbutton switch, the respective flow control valve closes. This stops the hot bleed air flow in order to prevent damage to the components of the air conditioning system and to prevent entry of smoke into the cabin.
 