(3)
On the CARGO HEAT panel 22VU:
-
make sure that the AFT ISOL VALVE pushbutton switch is in the OFF position.
-
make sure that the AFT cargo TEMP selector in the 12 o'clock position.
(4)
Do the EIS stop procedure
(Ref. TASK 31-60-00-860-002).
Subtask 21-43-00-862-059
B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
1EFF : ALL 1 21-43-00Page 506 1 1 Aug 01/05R 1 1 1CES 1
TASK 21-43-00-740-002 Power-up (BITE) Test of the Cargo-Compartment Heating Controller
1.
Reason for the Job
__________________
Referenced from the TSM.
2.
Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power 31-60-00-860-001 EIS Start Procedure 31-60-00-860-002 EIS Stop Procedure
3. Job Set-up
__________ Subtask 21-43-00-861-067
A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002) Subtask 21-43-00-865-086
B. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION FIN LOCATION -------------------------------------------------------------------------------122VU AIR COND/AFT CARGO VENT/CTL AND/MONG 31HN 20 S or alternative location :-
49VU AIR COND/AFT CARGO/VENT/CTL & MONG 31HN 07 C
1EFF : ALL 1 21-43-00Page 507 1 1 Feb 01/05R 1 1 1CES 1
Subtask 21-43-00-860-054
C. Aircraft Maintenance Configuration
(1)
Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. TASK 31-60-00-860-001).
(2)
Call up the COND page on the ECAM lower display unit.
4. Procedure
_________ Subtask 21-43-00-710-061
A. CHC (AFT Cargo Compartment) Power-up Test
(1)
Open the circuit breaker 31HN for a least 1 second.
(2)
Close the circuit breaker 31HN.
NOTE : This will do a power-up (BITE) test of the CHC.
____
________
5. Close-up
Subtask 21-43-00-860-055
A. Aircraft Maintenance Configuration
(1) Do the EIS stop procedure
(Ref. TASK 31-60-00-860-002).
Subtask 21-43-00-862-066
B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002)
CARGO COMPARTMENT HEATING - CLEANING/PAINTING
_____________________________________________
TASK 21-43-00-100-001
R Cleaning of the Cargo Compartment Duct-Temperature Sensors 3HC, 4HC and/or 13HC R and the Cargo Compartment-Temperature Sensor 14HC
WARNING : MAKE SURE THAT THERE IS A GOOD FLOW OF AIR THROUGH THE WORK AREA WHEN
_______ YOU USE SPECIAL MATERIALS. IF YOU GET ONE OF THESE MATERIALS ON YOUR SKIN, IN YOUR MOUTH OR IN YOUR EYES : -FLUSH IT AWAY WITH A FLOW OF CLEAN WATER FOR BETWEEN 10 AND 15 MINUTES. -GET IMMEDIATE MEDICAL AID IF IRRITATION OCCURS. DO NOT BREATHE THE FUMES FROM THE MATERIAL. DO NOT SMOKE WHEN YOU USE THE MATERIAL. DO NOT USE THE MATERIAL NEAR A FLAME, SPARKS OR SOURCES OF HEAT. THESE MATERIALS ARE DANGEROUS : THEY ARE POISONOUS, FLAMMABLE AND SKIN IRRITANTS.
WARNING : MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM
_______
FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE.
HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
R NOTE : The procedure is the same for the duct temperature sensors 3HC, 4HC
____ R and/or 13HC and the compartment temperature sensor 14HC.
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
No specific lint free cloth
No specific non-metallic soft bristle brush
No specific access platform 2 m (6 ft. 7 in.)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM AIR CONDITIONING 空调 3(70)