- the ACSC2 (57HH) connector AA/5E to the ACSC1 (47HH) connector AA/3F,
- the ACSC2 (57HH) connector AA/5F to the ACSC1 (47HH) connector AA/3G.
(1) If the fault continues:
- replace the CONT-AIR COND SYSTEM 2 (57HH) (Ref. AMM TASK 21-61-34-000-002) and (Ref. AMM TASK 21-61-34-400-002).
(2) If the fault continues:
- replace the CONT-AIR COND SYSTEM 1 (47HH) (Ref. AMM TASK 21-61-34-000-002) and (Ref. AMM TASK 21-61-34-400-002).
B. Do the test as given in the Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 401-499, ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page B222
Aug 01/05 CES
TASK 21-61-00-810-890
ACSC2/ACSC1 Bus 2 Fault
1. Possible Causes
_______________
- CONT-AIR COND SYSTEM 2 (57HH)
- CONT-AIR COND SYSTEM 1 (47HH)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 21-61-00-710-001 Operational Test of the Pack Temperature-Control System AMM 21-61-34-000-002 Removal of the Air-Conditioning System Controller (47HH, 57HH) AMM 21-61-34-400-002 Installation of the Air-Conditioning System Controller (47HH, 57HH) ASM 21-61/03
3. Fault Confirmation
__________________
A. Do the operational test of the pack temperature-control system (Ref. AMM TASK 21-61-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ACSC2(57HH)/ACSC1(47HH) /WRG: ACSC2 BUS2 TO ACSC1:
- do a check and repair the wiring (Ref. ASM 21-61/03) from:
- the ACSC2 (57HH) connector AA/6E to the ACSC1 (47HH) connector AA/4E,
- the ACSC2 (57HH) connector AA/6F to the ACSC1 (47HH) connector AA/4F.
(1) If the fault continues:
- replace the CONT-AIR COND SYSTEM 2 (57HH) (Ref. AMM TASK 21-61-34-000-002) and (Ref. AMM TASK 21-61-34-400-002).
(2) If the fault continues:
- replace the CONT-AIR COND SYSTEM 1 (47HH) (Ref. AMM TASK 21-61-34-000-002) and (Ref. AMM TASK 21-61-34-400-002).
B. Do the test as given in the Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 401-499, ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page B223
Aug 01/05 CES
TASK 21-61-00-810-891
ACSC1/ACSC2 Bus 1 Fault
1. Possible Causes
_______________
- CONT-AIR COND SYSTEM 1 (47HH)
- CONT-AIR COND SYSTEM 2 (57HH)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 21-61-00-710-001 Operational Test of the Pack Temperature-Control System AMM 21-61-34-000-002 Removal of the Air-Conditioning System Controller (47HH, 57HH) AMM 21-61-34-400-002 Installation of the Air-Conditioning System Controller (47HH, 57HH) ASM 21-61/03
3. Fault Confirmation
__________________
A. Do the operational test of the pack temperature-control system (Ref. AMM TASK 21-61-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ACSC1(47HH)/ACSC2(57HH) /WRG: ACSC1 BUS1 TO ACSC2:
- do a check and repair the wiring (Ref. ASM 21-61/03) from:
- the ACSC1 (47HH) connector AA/5E to the ACSC2 (57HH) connector AA/3F,
- the ACSC1 (47HH) connector AA/5F to the ACSC2 (57HH) connector AA/3G.
(1) If the fault continues: