- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 21-61-00-710-001 Operational Test of the Pack Temperature-Control
System AMM 21-61-34-000-001 Removal of the Pack Controller (7HH, 27HH) AMM 21-61-34-400-001 Installation of the Pack Controller (7HH, 27HH) AMM 21-61-52-000-001 Removal of the Air-Outlet Flap Actuator 9HH (29HH) AMM 21-61-52-400-001 Installation of the Air-Outlet Flap Actuator 9HH
(29HH)
ASM 21-61/04
3. Fault Confirmation
__________________
A. Do the operational test of the pack temperature-control system (Ref. AMM TASK 21-61-00-710-001).
NOTE : If a fault is detected, the PC gives a fault code for shop
____ maintenance in addition to the related CFDS message(s) (refer to TSM chapter 21-63-00, page block 301).
4. Fault Isolation
_______________
A. If the test gives the maintenance message TEST OK, but the POST FLIGHT REPORT and/or the PREVIOUS LEG REPORT gives the maintenance message P1 RAM AIR OUT ACTUATOR:
- replace the ACTUATOR-AIR OUTLET FLAP (9HH) (Ref. AMM TASK 21-61-52-000-001) and (Ref. AMM TASK 21-61-52-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-003, 051-054, ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page 261
May 01/05 CES
B. If the pack 1 ram-air outlet-actuator does not operate correctly on the ground with the pushbutton switch PACK 1, which is installed on the panel 30VU, in the OFF position:
- replace the ACTUATOR-AIR OUTLET FLAP (9HH) (Ref. AMM TASK 21-61-52-000-001) and (Ref. AMM TASK 21-61-52-400-001).
C. If the test gives the maintenance message P1 RAM AIR OUT ACTUATOR:
- replace the ACTUATOR-AIR OUTLET FLAP (9HH) (Ref. AMM TASK 21-61-52-000-001) and (Ref. AMM TASK 21-61-52-400-001).
(1) If the fault continues:
- do a check and repair the wiring (Ref. ASM 21-61/04) from:
- the ACTUATOR (9HH) to the PC 1 (7HH) and,
- the ACTUATOR (9HH) to ground.
(2) If the fault continues:
- replace the CONTROLLER-PACK 1 TEMP (7HH) (Ref. AMM TASK 21-61-34-000-001) and (Ref. AMM TASK 21-61-34-400-001).
D. Do the test as given in the Para. 3.A.
5. Close-up
________
A. Put the aircraft back to its initial configuration.
TASK 21-61-00-810-815
Pack 2 Air Outlet Flap Actuator Fault
CAUTION : DO NOT SWAP THE PACK/ACS CONTROLLERS. THIS CAN CAUSE DAMAGE TO THEM
_______
IF THERE IS AN ELECTRICAL FAULT IN THE ACTUATOR.
1. Possible Causes
_______________
- ACTUATOR-AIR OUTLET FLAP (29HH)
- CONTROLLER-PACK 2 TEMP (27HH)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 21-61-00-710-001 Operational Test of the Pack Temperature-Control
System AMM 21-61-34-000-001 Removal of the Pack Controller (7HH, 27HH) AMM 21-61-34-400-001 Installation of the Pack Controller (7HH, 27HH) AMM 21-61-52-000-001 Removal of the Air-Outlet Flap Actuator 9HH (29HH) AMM 21-61-52-400-001 Installation of the Air-Outlet Flap Actuator 9HH
(29HH)
ASM 21-61/02
3. Fault Confirmation
__________________
A. Do the operational test of the pack temperature-control system (Ref. AMM TASK 21-61-00-710-001).
NOTE : If a fault is detected, the PC gives a fault code for shop
____ maintenance in addition to the related CFDS message(s) (refer to TSM chapter 21-63-00, page block 301).
4. Fault Isolation
_______________
A. If the test gives the maintenance message TEST OK, but the POST FLIGHT REPORT and/or the PREVIOUS LEG REPORT gives the maintenance message P2 RAM AIR OUT ACTUATOR:
- replace the ACTUATOR-AIR OUTLET FLAP (29HH) (Ref. AMM TASK 21-61-52-000-001) and (Ref. AMM TASK 21-61-52-400-001).
B. If the pack 2 ram-air outlet-actuator does not operate correctly on the ground with the pushbutton switch PACK 2, which is installed on the panel 30VU, in the OFF position:
- replace the ACTUATOR-AIR OUTLET FLAP (29HH) (Ref. AMM TASK 21-61-52-000-001) and (Ref. AMM TASK 21-61-52-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-003, 051-054, ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page 263