R **ON A/C 401-499,
C. If the test gives the maintenance message P1 RAM AIR IN ACTUATOR(8HH):
- replace the ACTUATOR-AIR INLET FLAP (8HH) (Ref. AMM TASK 21-61-51-000-001) and (Ref. AMM TASK 21-61-51-400-001).
(1) If the fault continues:
- do a check and repair the wiring (Ref. ASM 2161S04) from:
- the ACTUATOR (8HH) to the ACSC1 (47HH) and,
- the ACTUATOR (8HH) to ground.
**ON A/C ALL
D. Do the test as given in the Para. 3.A.
5. Close-up
________
A. Put the aircraft back to its initial configuration.
TASK 21-61-00-810-813
Pack 2 Air Inlet Flap Actuator Fault
1. Possible Causes
_______________
- ACTUATOR-AIR INLET FLAP (28HH)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
ASM 2161S02 AMM 21-61-00-710-001 Operational Test of the Pack Temperature-Control
System AMM 21-61-51-000-001 Removal of the Air-Inlet Flap Actuator 8HH and 28HH AMM 21-61-51-400-001 Installation of the Air-Inlet Flap Actuator 8HH and
28HH
ASM 21-61/02
3. Fault Confirmation
__________________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
A. Do the operational test of the pack temperature-control system (Ref. AMM TASK 21-61-00-710-001).
NOTE : If a fault is detected, the PC gives a fault code for shop
____ maintenance in addition to the related CFDS message(s) (refer to TSM chapter 21-63-00, page block 301).
R **ON A/C 401-499,
A. Do the operational test of the pack temperature-control system (Ref. AMM TASK 21-61-00-710-001).
**ON A/C ALL
4. Fault Isolation
_______________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
A. If the test gives the maintenance message TEST OK, but the POST FLIGHT REPORT and/or the PREVIOUS LEG REPORT gives the maintenance message P2 RAM AIR IN ACTUATOR:
- replace the ACTUATOR-AIR INLET FLAP (28HH) (Ref. AMM TASK 21-61-51-000-001) and (Ref. AMM TASK 21-61-51-400-001).
R **ON A/C 401-499,
A. If the test gives the maintenance message TEST OK, but the POST FLIGHT REPORT and/or the PREVIOUS LEG REPORT gives the maintenance message P2 RAM AIR IN ACTUATOR(28HH):
- replace the ACTUATOR-AIR INLET FLAP (28HH) (Ref. AMM TASK 21-61-51-000-001) and (Ref. AMM TASK 21-61-51-400-001).
**ON A/C ALL
B. If the pack 2 ram-air inlet-actuator does not operate correctly on the ground with the pushbutton switch PACK 2, which is installed on the panel 30VU, in the OFF position:
- replace the ACTUATOR-AIR INLET FLAP (28HH) (Ref. AMM TASK 21-61-51-000-001) and (Ref. AMM TASK 21-61-51-400-001).
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
C. If the test gives the maintenance message P2 RAM AIR IN ACTUATOR:
- replace the ACTUATOR-AIR INLET FLAP (28HH) (Ref. AMM TASK 21-61-51-000-001) and (Ref. AMM TASK 21-61-51-400-001).
(1) If the fault continues:
- do a check and repair the wiring (Ref. ASM 21-61/02) from:
- the ACTUATOR (28HH) to the PC 2 (27HH) and,
- the ACTUATOR (28HH) to ground.
R **ON A/C 401-499,
C. If the test gives the maintenance message P2 RAM AIR IN ACTUATOR(28HH):
- replace the ACTUATOR-AIR INLET FLAP (28HH) (Ref. AMM TASK 21-61-51-000-001) and (Ref. AMM TASK 21-61-51-400-001).
(1) If the fault continues:
- do a check and repair the wiring (Ref. ASM 2161S02) from:
- the ACTUATOR (28HH) to the ACSC2 (57HH) and,
- the ACTUATOR (28HH) to ground.
**ON A/C ALL
D. Do the test as given in the Para. 3.A.
5. Close-up
________
A. Put the aircraft back to its initial configuration.
INTENTIONALLY BLANK
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page 260
R **ON A/C 001-003, 051-054,
TASK 21-61-00-810-814
Pack 1 Air Outlet Flap Actuator Fault
CAUTION : DO NOT SWAP THE PACK/ACS CONTROLLERS. THIS CAN CAUSE DAMAGE TO THEM
_______
IF THERE IS AN ELECTRICAL FAULT IN THE ACTUATOR.
1. Possible Causes
_______________
- ACTUATOR-AIR OUTLET FLAP (9HH)
- CONTROLLER-PACK 1 TEMP (7HH) 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调2(33)