R **ON A/C 401-499,
C. If the test confirms the fault:
- do a check that the resistance of the compressor temperature sensor (32HH) measured between connector A/A and A/B is in these limits (Ref. ASM 21-61/02):
Temp (Deg.C) OHMS ---------------------------
+ 10 103.9 +/- 0.5
+ 20 107.8 +/- 0.5
+ 30 111.7 +/- 0.5
+ 50 119.4 +/- 0.5
+ 70 127.1 +/- 0.5
+ 100 138.5 +/- 0.5
(1) If the resistance values are out of the specified limits:
- replace the SENSOR-COMPRESSOR TEMPERATURE (32HH) (Ref. AMM TASK 21-61-11-000-001) and (Ref. AMM TASK 21-61-11-400-001).
(2) If the fault continues: Replace the SENSOR-PRESS, PACK 2 INLET (24HB1) (Ref. AMM TASK 21-51-11-000-001) and (Ref. AMM TASK 21-51-11-400-001).
(3) If the fault continues:
(a) Swap the SDACIs (1WV1 and 1WV2). (Ref.AMM Task 31-55-34-401)
(b) If this action has solved the problem:
- replace the SDAC which formerly was SDAC#1.
(4) If the fault continues:
(a) Open the CBIs for the ACSC1+2.
(b) Disconnect the ACSC1 and 2. (Ref.AMM Task 21-61-34-401)
(c) Disconnect the electrical connectors at the FCS#1(23HB) and FCS#2(24HB).
- (Ref.AMM Task 21-51-51-401).
(d) Disconnect the SDAC#1.
(e) Do a check for GND at the SDAC#1 connector AA pin 10D.
(f) Do a check for GND at the SDAC#1 connector AA pin 13B.
NOTE : there should be no GND contact
____
(g) If there is no GND contact, reconnect the SDAC#1.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 401-499, ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page 234
Aug 01/05 CES
(h) If there is GND contact, do a check of the wiring and repair if
nessesary.
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
D. If the test gives the maintenance message TEST OK, but the FAULT legend on the pushbutton switch AIR COND/PACK 2, which is installed on the panel 30VU, comes on:
- do the operational test of the annunciator light test system (Ref. AMM TASK 33-14-00-710-001).
(1) If the test gives a different maintenance message refer to the Fault Symptom List.
(2) If the fault continues:
- do a check of the PUSHBUTTON SWITCH-AIR COND/PACK 2 (6HB) and replace it if necessary (Ref. ASM 21-51/02).
(3) If the fault continues:
- do a check of the BOARD-ANN LT TEST & INTFC (20LP) and replace it if necessary (Ref. ASM 21-51/02).
(4) If the fault continues:
- replace the CONTROLLER-PACK 2 TEMP (27HH) (Ref. AMM TASK 21-61-34-000-001) and (Ref. AMM TASK 21-61-34-400-001).
(5) If the fault continues:
- do a check and repair the wiring between: RELAY (20LP) connector A/30 and SW (6HB) connector A/7, RELAY (20LP) connector A/41 and GND, RELAY (20LP) connector A/27 and PC 2 (27HH) connector AB/7A RELAY (20LP) connector A/27 and RELAY (14HB) connector B/A2, RELAY (20LP) connector A/29 and CB (2HB) (Ref. ASM 21-51/02).
R **ON A/C 401-499,
D. If the test gives the maintenance message TEST OK, but the FAULT legend on the pushbutton switch AIR COND/PACK 2, which is installed on the panel 30VU, comes on:
- do the operational test of the annunciator light test system (Ref. AMM TASK 33-14-00-710-001).
(1) If the test gives a different maintenance message refer to the Fault Symptom List.
(2) If the fault continues:
- do a check of the PUSHBUTTON SWITCH-AIR COND/PACK 2 (6HB) and replace it if necessary (Ref. ASM 21-51/02).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page 235
Aug 01/05 CES
R (3) If the fault continues:
R - do a check of the BOARD-ANN LT TEST & INTFC (20LP) and replace it
R if necessary (Ref. ASM 21-51/02).
R (4) If the fault continues:
R - replace the CONT-AIR COND SYSTEM 2 (57HH) (Ref. AMM TASK 21-61-34-
R 000-002) and (Ref. AMM TASK 21-61-34-400-002).
R (5) If the fault continues:
R - do a check and repair the wiring (Ref. ASM 2151S02) from:
R - the RELAY (20LP)A pin 30 to the SW (6HB)A pin 7,
R - the RELAY (20LP)A pin 41 to ground,
R - the RELAY (20LP)A pin 27 to the ACSC2 (57HH),
R - the RELAY (20LP)A pin 27 to the RELAY (14HB)B pin A2 and,
中国航空网 www.aero.cn
航空翻译 www.aviation.cn