- swap back the ACSC2 (57HH) and replace the CONT-AIR COND SYSTEM 1 (47HH) (ACSC1 47HH).
(2) If the fault does not move with the ACSC1:
- swap back the ACSC1 (47HH) and the ACSC2 (57HH).
- replace the VALVE-TURBINE BYPASS (10HH) (Ref. AMM TASK 21-61-53-000-001) and (Ref. AMM TASK 21-61-53-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 401-499, ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page A297
Aug 01/05 CES (3) If the fault continues:
- do a check and repair the wiring (Ref. ASM 21-61/01) from:
- the VALVE (10HH) to the ACSC1 (47HH) and,
- the VALVE (10HH) to ground.
B. Put the aircraft back to its initial configuration.
TASK 21-61-00-810-869
ACSC2 / Pack 2 Bypass Valve Fault
1. Possible Causes
_______________
- CONT-AIR COND SYSTEM 2 (57HH)
- VALVE-TURBINE BYPASS (30HH)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 21-61-00-710-001 Operational Test of the Pack Temperature-Control System AMM 21-61-34-000-002 Removal of the Air-Conditioning System Controller (47HH, 57HH) AMM 21-61-34-400-002 Installation of the Air-Conditioning System
Controller (47HH, 57HH) AMM 21-61-53-000-001 Removal of the Bypass Valve 10HH (30HH) AMM 21-61-53-400-001 Installation of the Bypass Valve 10HH (30HH) ASM 21-61/02
3. Fault Confirmation
__________________
A. Do the operational test of the pack temperature-control system (Ref. AMM TASK 21-61-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the maintenance message ACSC2(57HH)/P2 BYPASS
VALVE(30HH):
- swap the ACSC2 (57HH) and the ACSC1 (47HH) (Ref. AMM TASK 21-61-34-000-002) and (Ref. AMM TASK 21-61-34-400-002).
(1) If the fault moves with the ACSC2:
- swap back the ACSC1 (57HH) and replace the CONT-AIR COND SYSTEM 2 (57HH) (ACSC2 57HH).
(2) If the fault does not move with the ACSC2:
- swap back the ACSC2 (47HH) and the ACSC1 (57HH).
- replace the VALVE-TURBINE BYPASS (30HH) (Ref. AMM TASK 21-61-53-000-001) and (Ref. AMM TASK 21-61-53-400-001).
(3) If the fault continues:
- do a check and repair the wiring (Ref. ASM 21-61/02) from:
- the VALVE (30HH) to the ACSC2 (57HH) and,
- the VALVE (30HH) to ground.
B. Do the test as given in the PARA. 3.A.
**ON A/C ALL
TASK 21-61-00-810-870 Pack 1/2 Compressor Outlet Temperature Fault WARNING : PUT ON PROTECTIVE GOGGLES AND THERMAL GLOVES WHEN YOU GO NEAR AN
_______ AIR-CONDITIONING PACK WHEN IT OPERATES. THERE CAN BE LEAKAGE OF HOT AIR, WHICH CAN CAUSE INJURIES.
1. Possible Causes
_______________
- heat exchanger unit
- seals
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 12-33-21-618-001 Pre-conditioning through the LP Ground Connection AMM 12-33-21-618-001 Pre-conditioning with the APU
3. Fault Confirmation
__________________
A. Access
(1) Get access to the heat exchanger areas for both packs.
B. Test NOTE : The fault indications cannot be reproduced on the ground.
____
(1) Do the pre-conditioning with the APU (Ref. AMM TASK 12-33-21-618-001).
4. Fault Isolation
_______________
A. Leak Check
(1) In each heat exchanger unit area do a check for hot air leaks at:
- the duct connections, the welded joints and all component surfaces.
(2) Leaks must be removed either by replacement of the applicable seals or by replacement of the faulty component.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page B201
Aug 01/05R CES