TASK 21-61-00-810-831
Pack 2 Outlet Temperature Sensor Fault
1. Possible Causes
_______________
- SENSOR-PACK OUTLET TEMP (34HH)
- CHECK VALVE-TRIM AIR (19HM)
- SENSOR-PACK OUTLET TEMPERATURE (34HH)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 21-61-00-710-001 Operational Test of the Pack Temperature-Control System AMM 21-61-15-000-001 Removal of the Pack Outlet - Temperature Sensors 13HH and 34HH AMM 21-61-15-400-001 Installation of the Pack Outlet - Temperature Sensors 13HH and 34HH AMM 21-63-42-210-001 Detailed Visual Inspection of Trim-Air Check-Valves
Flappers for Condition and Operation
ASM 21-61/02
ASM 21-61/02
3. Fault Confirmation
__________________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
A. Do the operational test of the pack temperature-control system (Ref. AMM TASK 21-61-00-710-001).
NOTE : If a fault is detected, the PC gives a fault code for shop
____ maintenance in addition to the related CFDS message(s) (refer to TSM chapter 21-63-00, page block 301).
R **ON A/C 401-499,
A. Do the operational test of the pack temperature-control system (Ref. AMM TASK 21-61-00-710-001).
**ON A/C ALL
4. Fault Isolation
_______________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
A. If the test gives the maintenance message P2 OUTLET TEMP SENSOR:
- replace the SENSOR-PACK OUTLET TEMPERATURE (34HH) (referred to as SENSOR (34HH)) (Ref. AMM TASK 21-61-15-000-001) and (Ref. AMM TASK 21-61-15-400-001).
(1) If the fault continues:
- do a check and repair the wiring between: SENSOR (34HH) connector A/C and PC 2 (27HH) connector AB/12A, SENSOR (34HH) connector A/B and PC 2 (27HH) connector AB/12B, SENSOR (34HH) connector A/A and PC 2 (27HH) connector AB/11D (Ref. ASM 21-61/02).
(2) If the fault continues:
- do a visiual inspection of the trim-air check-valve flappers (Ref. AMM TASK 21-63-42-210-001), and replace this valve if nessesary.
R **ON A/C 401-499,
A. If the test gives the maintenance message P2 OUT TEMP SENSOR(34HH):
- replace the SENSOR-PACK OUTLET TEMP (34HH) (Ref. AMM TASK 21-61-15-000-001) and (Ref. AMM TASK 21-61-15-400-001).
(1) If the fault continues:
- do a check and repair the wiring (Ref. ASM 21-61/02) from:
- the SENSOR (34HH) to the ACSC2 (57HH) and,
- the SENSOR (34HH) to ground.
(2) If the fault continues:
- do a visual inspection of the CHECK VALVE-TRIM AIR (19HM) flappers (Ref. AMM TASK 21-63-42-210-001), and replace this valve if nessesary.
**ON A/C ALL
B. Do the test as given in the Para. 3.A.
5. Close-up
________
A. Put the aircraft back to its initial configuration.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page A226
Aug 01/05 CES
TASK 21-61-00-810-832
Pack 1 High Discharge Temperature
1. Possible Causes
_______________
- MACHINE-AIR CYCLE (10HM1)
- SENSOR-WATER EXTRACTOR TEMPERATURE (11HH)
- CONTROLLER-PACK 1 TEMP (7HH)
- SENSOR-PACK OUTLET PNEUMATIC (10HM10)
- VALVE-ANTI ICE (17HH)
- VALVE-FLOW CTL (11HB)
- CONT-AIR COND SYSTEM 1 (47HH)
- SENSOR-PACK INLET PRESSURE (16HH)
- SENSOR-PRESS, PACK 1 INLET (23HB1)
- ram-air inlet door mechanism
- ram-air outlet
- water injector nozzle
- clogged main heat exchanger
- clogged primary heat exchanger
- wiring
- clogged reheater (10HM3)
- clogged condensor (10HM2)
- water drain line
- clogged main heat exchanger (10HM7)
- clogged primary heat exchanger (10HM6) 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调2(57)