R - the PRESSURE SENSOR (24HB1) to the ACSC2 (57HH).

 B. Do the test as given in the Para. 3.A.

 TASK 21-51-00-810-824


 Pack 1/2 Inlet Pressure Sensor Fault
 1. Possible Causes
_______________
 - SENSOR-PRESS, PACK 1 INLET (23HB1)

 - SENSOR-PRESS, PACK 2 INLET (24HB1)

 - CONT-AIR COND SYSTEM 1 (47HH)

 - CONT-AIR COND SYSTEM 2 (57HH)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
AMM 12-33-21-618-001 Pre-conditioning through the LP Ground Connection AMM 21-61-16-000-001 Removal of the Pack-Inlet Pressure Sensor 16HH (36HH) AMM 21-61-16-400-002 Installation of the Pack-Inlet Pressure Sensor 16HH
 (36HH) AMM 21-61-34-000-002 Removal of the Air-Conditioning System Controller (47HH, 57HH) AMM 21-61-34-400-002 Installation of the Air-Conditioning System
 Controller (47HH, 57HH)
 ASM 21-61/01
 ASM 21-61/02

 3. Fault Confirmation
__________________
 A. Test
 (1) Do the pre-conditioning of the air conditioning system with the APU (Ref. AMM TASK 12-33-21-618-001)

 (2) After approx. 4 minutes, stop the pre-conditioning.


 NOTE : If a fault is detected, the ACSC1 gives a fault code for shop
____ maintenance in addition to the related CFDS message(s) (refer to TSM chapter 21-63-00, page block 301).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message,
 P1 PR INL SENS(23HB1)/ P2 PRESS INL SENS(24HB1):

 - replace the SENSOR-PRESS, PACK 1 INLET (23HB1) (Ref. AMM TASK 21-61-16-000-001) and (Ref. AMM TASK 21-61-16-400-002).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 401-499, ∞∞21-51-00∞∞∞∞∞∞∞∞∞∞Page 268
 Aug 01/05 CES B. If the fault continues:


 - replace the SENSOR-PRESS, PACK 2 INLET (24HB1) (Ref. AMM TASK 21-61-16-000-001) and (Ref. AMM TASK 21-61-16-400-002).
 C. If the fault continues:
 - replace the CONT-AIR COND SYSTEM 1 (47HH) (Ref. AMM TASK 21-61-34-000-002) and (Ref. AMM TASK 21-61-34-400-002).
 (1) If the fault continues:
 - replace the CONT-AIR COND SYSTEM 2 (57HH) (Ref. AMM TASK 21-61-34-000-002) and (Ref. AMM TASK 21-61-34-400-002).
 D. If the fault continues:
 - do a check and repair the wiring (Ref. ASM 21-61/01) from:

 - the PRESSURE SENSOR (23HB1) to the ACSC1 (47HH).

 - do a check and repair the wiring (Ref. ASM 21-61/02) from:

 - the PRESSURE SENSOR (24HB1) to the ACSC2 (57HH).


 E. Do the test as given in the Para. 3.A.

 TASK 21-51-00-810-825


 Pack 1 P/BSW Fault
 1. Possible Causes
_______________
 - P/BSW-AIR COND/PACK 1 (7HB)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM  21-61-00-710-001 Operational Test of the Pack Temperature-Control System ASM 21-51/02
 3. Fault Confirmation
__________________
 A. Do the operational test of the pack temperature-control system (Ref. AMM TASK 21-61-00-710-001).
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message PACK P-B(7HB) / WIRING:
 - do a check of the P/BSW-AIR COND/PACK 1 (7HB) and replace it if necessary (Ref. ASM 21-51/02).
 (1) If the fault continues:
 - do a check and repair the wiring (Ref. ASM 21-51/02) from:

 - the CONT-AIR COND SYSTEM 1 (47HH) to the
 PUSHBUTTON SWITCH-AIR COND/PACK 1 (7HB).

 

 B. Do the test as given in the Para. 3.A.

 TASK 21-51-00-810-826


 Pack 2 P/BSW Fault
 1. Possible Causes
_______________
 - P/BSW-AIR COND/PACK 2 (6HB)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM  21-61-00-710-001 Operational Test of the Pack Temperature-Control System ASM 21-51/01
 