• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 09:16来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 ASM 21-63/03

 3. Fault Confirmation
__________________
 A. Do the operational test of the cockpit and cabin temperature-control system with CFDS/MCDU (Ref. AMM TASK 21-63-00-710-004).
 NOTE : If a fault is detected, the ZC gives a fault code for shop
____ maintenance in addition to the related CFDS message(s). For detailed information see the applicable Page Block 301.
 4. Fault Isolation
_______________
 A. If the test gives the maintenance message TEMP SENSOR L/H AND R/H MIXER:
 - replace the SENSOR-MIXER UNIT TEMPERATURE COCKPIT (24HK) (referred to as SENSOR (24HK)) (Ref. AMM TASK 21-63-16-000-001) and (Ref. AMM TASK 21-63-16-400-001),

 - replace the SENSOR-MIXER UNIT TEMPERATURE CABIN (25HK) (referred to as SENSOR (25HK)) (Ref. AMM TASK 21-63-16-000-001) and (Ref. AMM TASK 21-63-16-400-001).


 (1) If the fault continues:
 - do a check and repair the wiring (Ref. ASM 21-63/03) between: SENSOR (24HK) connector A/E and ZC (8HK) connector AA/8C, SENSOR (24HK) connector A/F and ZC (8HK) connector AA/8D, SENSOR (24HK) connector A/C and ZC (8HK) connector AA/8H,
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-63-00∞∞∞∞∞∞∞∞∞∞Page 286
 Aug 01/05R CES


 SENSOR (24HK) connector A/D and ZC (8HK) connector AA/8G,
 SENSOR (24HK) connector A/A and GND,
 SENSOR (25HK) connector A/E and ZC (8HK) connector AA/10C,
 SENSOR (25HK) connector A/F and ZC (8HK) connector AA/10D,
 SENSOR (25HK) connector A/C and ZC (8HK) connector AA/10H,
 SENSOR (25HK) connector A/D and ZC (8HK) connector AA/10G,
 SENSOR (25HK) connector A/A and GND.

 (2) If the fault continues:
 - replace the CONT-ZONE TEMPERATURE (8HK) (Ref. AMM TASK 21-63-34-000-001) and (Ref. AMM TASK 21-63-34-400-001).
 B. Do the test as given in the Para. 3.A.


 **ON A/C 001-003, 051-052,

 TASK 21-63-00-810-842
 Actual Zone Temperatures are above Selected Zone Temperatures (In Flight)

 1. Possible Causes
_______________
 - cockpit ceiling panel 211HC

 - temperature-sensor air duct inlet-grill


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 25-13-41-400-001 Installation of the Ceiling Panels AMM 25-24-41-400-001 Installation of the Overhead Stowage Compartments
 3. Fault Confirmation
__________________
 A. Not applicable.
 4. Fault Isolation
_______________
 A. Make sure that:
 (1) For the cockpit temperature sensor 21HK:

 - the cockpit ceiling panel 211HC is flush with the temperature sensor housing (Ref. AMM TASK 25-13-41-400-001).

 - there is no gap between the ceiling panel and the temperature sensor housing.

 

 (2) For the cabin temperature sensors 22HK and 23HK:


 - the temperature-sensor air duct inlet-grill is correctly positioned in and over the air duct inlet (Ref. AMM TASK 25-24-41-400-001).


R **ON A/C 004-049, 053-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 TASK 21-63-00-810-843
 Actual Zone Temperatures are above Selected Zone Temperatures (In Flight)

 1. Possible Causes
_______________
 - temperature-sensor air duct inlet-grill
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 25-24-41-400-001 Installation of the Overhead Stowage Compartments
 3. Fault Confirmation
__________________
 A. Not applicable.
 4. Fault Isolation
_______________
 A. Make sure that:
 (1) For the cabin temperature sensors 22HK and 23HK:
 - the temperature-sensor air duct inlet-grill is correctly positioned in and over the air duct inlet (Ref. AMM TASK 25-24-41-400-001).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 004-049, 053-099, 101-149, 151-199, ∞∞21-63-00∞∞∞∞∞∞∞∞∞∞Page 289
 201-299, 301-399, 401-499, Aug 01/05 CES


 **ON A/C ALL
 TASK 21-63-00-810-844
 Zone Cont Electrical Component with Short Circuit (Primary Channel)
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调2(128)