1. Possible Causes
_______________
- CONTROLLER-PACK 2 TEMP (27HH)
- CONT-AIR COND SYSTEM 2 (57HH)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
21-61-00-810-821 Pack 2 Electrical Component with Short Circuit (AIR PACK 2 REGUL FAULT) AMM 21-61-00-710-001 Operational Test of the Pack Temperature-Control
System AMM 21-61-34-000-001 Removal of the Pack Controller (7HH, 27HH) AMM 21-61-34-000-002 Removal of the Air-Conditioning System Controller
(47HH, 57HH)
AMM 21-61-34-400-001 Installation of the Pack Controller (7HH, 27HH)
AMM 21-61-34-400-002 Installation of the Air-Conditioning System
Controller (47HH, 57HH)
ASM 21-61/01
ASM 21-63/02
3. Fault Confirmation
__________________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
A. Do the operational test of the pack temperature-control system (Ref. AMM TASK 21-61-00-710-001).
NOTE : If a fault is detected, the PC gives a fault code for shop
____ maintenance in addition to the related CFDS message(s) (refer to TSM chapter 21-63-00, page block 301).
R **ON A/C 401-499,
A. Do the operational test of the pack temperature-control system (Ref. AMM TASK 21-61-00-710-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page A277
Aug 01/05 CES **ON A/C ALL
4. Fault Isolation
_______________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
A. If the test gives the maintenance message P2 CONT:
- replace the CONTROLLER-PACK 2 TEMP (27HH) (Ref. AMM TASK 21-61-34-000-001) and (Ref. AMM TASK 21-61-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring if necessary between: PC 2 (27HH) connector AA/5A and CB (21HH), PC 2 (27HH) connector AA/5B and GND, PC 2 (27HH) connector AB/13D and CB (22HH), PC 2 (27HH) connector AB/14A and GND (Ref. ASM 21-61/01).
(2) If the fault continues:
- a check and repair if necessary the wiring of the signal: ARINC 429 XTR (P) from the ZC (8HK) to the PC 2 (27HH), ARINC 429 XTR (S) from the ZC (8HK) to the PC 2 (27HH), ARINC 429 RCV (S) from the ZC (8HK) to the PC 2 (27HH) (Ref. ASM 21-63/02).
(3) If the fault continues:
- do the trouble shooting procedures for the pack 2 electrical component with short circuit (Ref. TASK 21-61-00-810-821).
R **ON A/C 401-499,
A. If the test gives the maintenance message ACSC2(57HH):
- replace the CONT-AIR COND SYSTEM 2 (57HH) (Ref. AMM TASK 21-61-34-000-002) and (Ref. AMM TASK 21-61-34-400-002).
(1) If the fault continues:
- do the trouble shooting procedures for the pack 2 electrical component with short circuit (Ref. TASK 21-61-00-810-821).
**ON A/C ALL
B. Do the test as given in the Para. 3.A.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page A278
Aug 01/05 CES TASK 21-61-00-810-863 Pack 1 Control - No Test Result
1. Possible Causes
_______________
- VALVE-FLOW CTL (11HB)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 21-51-51-000-001 Removal of the Pack Flow-Control Valve AMM 21-51-51-400-001 Installation of the Pack Flow-Control Valve AMM 21-61-00-710-001 Operational Test of the Pack Temperature-Control
System ASM 21-51/01
3. Fault Confirmation
__________________
A. Do the operational test of the pack temperature-control system (Ref. AMM TASK 21-61-00-710-001).
4. Fault Isolation
_______________
A. If the test gives the message NO TEST RESULT RECEPTION FROM P1 CONT:
- replace the VALVE-FLOW CTL (11HB) (Ref. AMM TASK 21-51-51-000-001) and (Ref. AMM TASK 21-51-51-400-001).
(1) If the fault continues:
- do a check and the repair the wiring (Ref. ASM 21-51/01): from the PC1 (7HH)AB/6B to the FCV (11HB)A/D, from the PC1 (7HH)AA/7B to the FCV (8HB)A/C, from the FCV (11HB)A/B to the ground.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调2(76)