• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 09:16来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 


 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 004-049, 055-099, 101-149, 151-199, ∞∞21-51-00∞∞∞∞∞∞∞∞∞∞Page 252
 201-299, 301-399, 401-499, Aug 01/05 CES (3) On the ECAM BLEED page:


 - make sure that the pack 1 inlet pressure indication shows a minimum of 24 PSI.
 NOTE : If the indication shows less than 24 PSI you must:
____
 - increase the ground pressure supply until the indication shows a minimum of 24 PSI.
 B. Start the engines (Ref. AMM TASK 71-00-00-710-003) if necessary.
 4. Fault Isolation
_______________
R **ON A/C 004-049, 055-099, 101-149, 151-199, 201-299, 301-399,
 A. This procedure is only applicable for the Flow Control Valves P/N 751 series.
 (1) When the pack flow selector is at the LO or NORM position:
 - on the upper ECAM DU if the pack 1 flow shows in the HI flow position and both pack flow-control valve indications show green,
 - replace the VALVE-FLOW CTL (11HB) (Ref. AMM TASK 21-51-51-000-001) and (Ref. AMM TASK 21-51-51-400-001).
R **ON A/C 401-499,
 A. When the pack flow selector is at the LO or NORM position:
 - on the upper ECAM DU if the pack 1 flow shows in the HI flow position and both pack flow-control valve indications show green,
 - replace the FLOW CONTROL SYSTEM (23HB) (Ref. AMM TASK 21-51-51-000-001) and (Ref. AMM TASK 21-51-51-400-001).
 **ON A/C 004-049, 055-099, 101-105, 151-199, 201-299, 301-302,
 B. This procedure is only applicable for the Flow Control Valves P/N 1303 series.
 (1) When the pack flow selector is at the LO or NORM position:
 - on the upper ECAM DU if the pack 1 flow shows in the HI flow position and both pack flow-control valve indications show green,
 (a) do a check of the wiring (Ref. ASM 21-51/01) and (Ref. ASM 21-51/02) from:

 - the FCV (11HB/A) pin C to the PACK2 TEMP CONTROLLER (27HH/AA) pin 7B.

 (b) If the fault continues:


 - replace the VALVE-FLOW CTL (11HB) (Ref. AMM TASK 21-51-51-000-001) and (Ref. AMM TASK 21-51-51-400-001).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 004-049, 055-099, 101-149, 151-199, ∞∞21-51-00∞∞∞∞∞∞∞∞∞∞Page 253
 201-299, 301-399, 401-499, Aug 01/05 CESR **ON A/C 004-049, 055-099, 101-149, 151-199, 201-299, 301-399, 401-499,


 5. Close-up
________
 **ON A/C 004-049, 055-099, 101-105, 151-199, 201-299, 301-302,

 A. This procedure is only necessary after you do the work step Para. 4. B. (a).
 - Do the procedures given in para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 004-049, 055-099, 101-149, 151-199, ∞∞21-51-00∞∞∞∞∞∞∞∞∞∞Page 254
 201-299, 301-399, 401-499, Aug 01/05 CES


R **ON A/C 004-049, 055-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 TASK 21-51-00-810-816
 Pack 2 High Flow Indication
 1. Possible Causes
_______________
 - VALVE-FLOW CTL (8HB)

 - P2 FLOW CTL VALVE (8HB)

 - FLOW CONTROL SYSTEM (24HB)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 12-33-21-618-001 Pre-conditioning through the HP Ground Connection AMM 21-51-51-000-001 Removal of the Pack Flow-Control Valve AMM 21-51-51-400-001 Installation of the Pack Flow-Control Valve AMM 71-00-00-710-003 Engine Automatic Start ASM 21-51/01 ASM 21-51/01
 3. Fault Confirmation
__________________
 A. Bleed Air Supply Source from the HP Ground Connection
 NOTE : The HP ground supply source must be able to give a pack inlet
____ pressure of 24 PSI minimum. If it can not do this then you must get the bleed air supply from the engines. The work steps which follow show the conditions necessary before you get the minimum pack-inlet pressure.
 (1) Do the pre-conditioning through the HP ground connection (Ref. AMM TASK 12-33-21-618-001).

 (2) On the AIR COND panel 30VU:

 - push the HOT AIR pushbutton switch to the on position (the OFF legend goes off),

 - turn the COCKPIT, FWD CABIN and the AFT CABIN temperature selectors to the HOT positions and,

 - make sure that the PACK 1 and the PACK 2 pushbutton switches are in the on position (the OFF legends are off).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调2(6)