TASK 21-63-00-810-851
Pack 2 Trim Air Check Valve Fault
1. Possible Causes
_______________
- CHECK VALVE-TRIM AIR (19HM)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 21-63-00-710-005 Operational Test of the Trim Air Check-Valves AMM 21-63-42-000-001 Removal of the Trim-Air Check Valves 18HM and 19HM AMM 21-63-42-400-001 Installation of the Trim-Air Check Valves 18HM and
19HM
3. Fault Confirmation
__________________
A. Do an operational test of the trim air check-valve (Ref. AMM TASK 21-63-00-710-005).
4. Fault Isolation
_______________
A. If during the test the pack 2 discharge temperature increases:
- replace the CHECK VALVE-TRIM AIR (19HM) (Ref. AMM TASK 21-63-42-000-001) and (Ref. AMM TASK 21-63-42-400-001).
B. Do the test given in para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-63-00∞∞∞∞∞∞∞∞∞∞Page A212
Aug 01/05R
CES
TASK 21-63-00-810-852
Trim Air System Fault with CKPT Trim Air Valve position AMBER XX
1. Possible Causes
_______________
- TRIM VALVE CKPT (11HK)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 21-63-00-710-004
AMM 21-63-51-000-001 AMM 21-63-51-400-001 ASM 21-63/02
R ASM 21-63/03
3. Fault Confirmation
__________________
Operational Test of the Cockpit and Cabin Temperature
Control with CFDS/MCDU
Removal of the Trim Air Valve (11HK,12HK,13HK)
Installation of the Trim Air Valve (11HK,12HK,13HK)
A. Confirmation of the Fault
(1) Do the operational test of the cockpit and cabin temperature-control system (Ref. AMM TASK 21-63-00-710-004).
4. Fault Isolation
_______________
R **ON A/C 401-499,
R A. If the test does not confirm the fault:
R (1) Do the reset procedure for the ACSC1 as follows,
R - open the circuit breakers 49HH, 50HH, 51HH and 52HH.
R - wait for a minimum of 5 seconds.
R - close the circuit breakers 49HH, 50HH, 51HH and 52HH.
R (2) No further trouble shooting is necessary.
**ON A/C 151-199,
R B. If on the ECAM COND page the CKPT trim air valve position indication shows amber XX:
- replace the TRIM VALVE CKPT (11HK) (Ref. AMM TASK 21-63-51-000-001) and (Ref. AMM TASK 21-63-51-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-63-00∞∞∞∞∞∞∞∞∞∞Page A213
Aug 01/05 CES
(1) If the fault continues:
- do a check and repair the wiring (Ref. ASM 21-63/02) from:
- the TRIM AIR VALVE CKPT (11HK) to the Zone Controller (8HK) and,
- the TRIM AIR VALVE CKPT (11HK) to ground.
R **ON A/C 401-499,
R B. If on the ECAM COND page the CKPT trim air valve position indication
R shows amber XX:
R - replace the TRIM VALVE CKPT (11HK) (Ref. AMM TASK 21-63-51-000-001) and
R (Ref. AMM TASK 21-63-51-400-001).
R (1) If the fault continues:
R - do a check and repair the wiring (Ref. ASM 21-63/03) from:
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调2(138)