- the SENSOR-DUCT OVHT TEMPERATURE,FWD CABIN (19HK) to the ZC (8HK) and,
- the SENSOR-DUCT OVHT TEMPERATURE,FWD CABIN (19HK) to ground.
(4) If the fault continues:
- replace the VALVE-TRIM AIR,FWD CABIN (12HK) (Ref. AMM TASK 21-63-51-000-001) and (Ref. AMM TASK 21-63-51-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 051-052, ∞∞21-63-00∞∞∞∞∞∞∞∞∞∞Page 261
Aug 01/05R CES
(5) If the fault continues:
- do a check and repair the wiring (Ref. ASM 21-63/02) from:
- the VALVE-TRIM AIR,FWD CABIN (12HK) to the ZC (8HK) and,
- the VALVE-TRIM AIR,FWD CABIN (12HK) to ground.
(6) If the fault continues:
- replace the VALVE-PRESSURE REGULATING (14HK) (Ref. AMM TASK 21-63-52-000-001) and (Ref. AMM TASK 21-63-52-400-001).
(7) If the fault continues:
- do a check and repair the wiring (Ref. ASM 21-63/03) from:
- the VALVE-PRESSURE REGULATING (14HK) to the ZC (8HK) and,
- the VALVE-PRESSURE REGULATING (14HK) to ground.
(8) If the fault continues:
- replace the CONT-ZONE TEMPERATURE (8HK) (Ref. AMM TASK 21-63-34-000-001) and (Ref. AMM TASK 21-63-34-400-001).
B. If the test gives the maintenance message TEST OK, but on the ECAM upper DU the warning COND FWD CAB DUCT OVHT comes on:
- do a check of the FWD cabin-duct inlet temperature on the ECAM COND page.
(1) If the temperature is below 70 Deg.C:
- replace the SENSOR-DUCT OVHT TEMPERATURE,FWD CABIN (19HK) (Ref. AMM TASK 21-63-18-000-001) and (Ref. AMM TASK 21-63-18-400-001).
C. Do the test as given in the Para. 3.A.
5. Close-up
________
A. Put the aircraft back to its initial configuration.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 051-052, ∞∞21-63-00∞∞∞∞∞∞∞∞∞∞Page 262
Aug 01/05R
CES
TASK 21-63-00-810-825
AFT Cabin Duct Overheat Detection
1. Possible Causes
_______________
- SENSOR-DUCT TEMPERATURE,AFT CABIN (17HK)
- SENSOR-DUCT TEMPERATURE,AFT CABIN (20HK)
- VALVE-TRIM AIR,AFT CABIN (13HK)
- VALVE-PRESSURE REGULATING (14HK)
- CONT-ZONE TEMPERATURE (8HK)
- wiring
- SENSOR-DUCT OVHT TEMPERATURE,AFT CABIN (20HK)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 21-63-00-710-004 Operational Test of the Cockpit and Cabin Temperature Control with CFDS/MCDU AMM 21-63-15-000-001 Removal of the Duct Temperature Sensors 15HK, 16HK and 17HK AMM 21-63-15-400-001 Installation of the Duct Temperature Sensors 15HK, 16HK and 17HK AMM 21-63-18-000-001 Removal of the Duct Overheat-Temperature Sensors 18HK, 19HK and 20HK AMM 21-63-18-400-001 Installation of the Duct Overheat-Temperature Sensors
18HK, 19HK and 20HK AMM 21-63-34-000-001 Removal of the Zone Controller (8HK) AMM 21-63-34-400-001 Installation of the Zone Controller (8HK) AMM 21-63-51-000-001 Removal of the Trim Air Valve (11HK,12HK,13HK) AMM 21-63-51-400-001 Installation of the Trim Air Valve (11HK,12HK,13HK) AMM 21-63-52-000-001 Removal of the Pressure Regulating Valve 14HK AMM 21-63-52-400-001 Installation of the Pressure Regulating Valve 14HK ASM 21-63/03 ASM 21-63/03
3. Fault Confirmation
__________________
A. Do the operational test of the cockpit and cabin temperature-control system with CFDS/MCDU (Ref. AMM TASK 21-63-00-710-004).
NOTE : If a fault is detected, the ZC gives a fault code for shop
____ maintenance in addition to the related CFDS message(s). For detailed information see the applicable Page Block 301.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 051-052, ∞∞21-63-00∞∞∞∞∞∞∞∞∞∞Page 263
Aug 01/05R
CES
4. Fault Isolation
_______________
A. If the test confirms the fault:
- do a check that the resistance of the AFT cabin-duct temperature sensor (17HK) measured between connector A/E and A/F and connector A/C and A/D is in these limits (Ref. ASM 21-63/03):
Temp (Deg.C) OHMS ---------------------------
+ 10 18820 +/- 5 %