1_ If the fault continues:
- do the BITE test of the landing gear (Ref. AMM TASK 32-69-
00-740-001).
_ the Fault Symptom List.
(b) If there is a ground signal:
- replace the CONT-AIR COND SYSTEM 1 (47HH) (Ref. AMM TASK 21-61-34-000-002) and (Ref. AMM TASK 21-61-34-400-002).
**ON A/C ALL
F. Do the test as given in the Para. 3.A.
5. Close-up
________
A. Put the aircraft back to its initial configuration.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page A239
Aug 01/05R
CES TASK 21-61-00-810-833
Pack 2 High Discharge Temperature
1. Possible Causes
_______________
- MACHINE-AIR CYCLE (11HM1)
- SENSOR-WATER EXTRACTOR TEMPERATURE (31HH)
- CONTROLLER-PACK 2 TEMP (27HH)
- SENSOR-PACK OUTLET PNEUMATIC (11HM10)
- VALVE-ANTI-ICE (37HH)
- VALVE-FLOW CTL (8HB)
- CONT-AIR COND SYSTEM 2 (57HH)
- SENSOR-PACK INLET PRESSURE (36HH)
- SENSOR-PRESS, PACK 2 INLET (24HB1)
- ram-air inlet door mechanism
- ram-air outlet
- water injector nozzle
- clogged main heat exchanger (11HM7)
- clogged primary heat exchanger (11HM6)
- wiring
- clogged reheater (11HM3)
- clogged condenser (11HM2)
- water drain line
- FLOW CONTROL SYSTEM (24HB)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
ASM 2161S02
AMM 12-33-21-618-001 Pre-conditioning with the APU
AMM 21-51-13-000-001 Removal of the Pack-Inlet Pressure Sensor 23HB1
(24HB1) AMM 21-51-13-400-001 Installation of the Pack-Inlet Pressure Sensor 23HB1
(24HB1) AMM 21-51-51-000-001 Removal of the Pack Flow-Control Valve AMM 21-51-51-400-001 Installation of the Pack Flow-Control Valve AMM 21-52-00-100-001 Cleaning of the Air Conditioning Pack-Primary Heat
Exchanger 10HM6 (11HM6) and the Main Heat Exchanger 10HM7 (11HM7) AMM 21-52-00-100-002 Cleaning of the Air Conditioning Pack-Reheater 10HM3 (11HM3) AMM 21-52-00-100-003 Cleaning of the Air Conditioning Pack-Condensor 10HM2
(11HM2) AMM 21-52-00-780-001 Pressure Drop Test of the Reheater 10HM3 (11HM3) AMM 21-52-00-960-001 Replacement of the Water Injector Nozzle AMM 21-52-16-000-001 Removal of the Water Extractor 10HM8 (11HM8)
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page A240
Aug 01/05 CES -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 21-52-16-400-001
AMM 21-52-21-000-001
AMM 21-52-21-400-001
AMM 21-52-42-000-001
AMM 21-52-42-400-001
AMM 21-61-13-000-001
AMM 21-61-13-400-001
AMM 21-61-16-000-001
AMM 21-61-16-400-002
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调2(63)