• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 09:16来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 - clogged condenser (10HM2)

 - FLOW CONTROL SYSTEM (23HB)


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
ASM 2161S04 AMM 12-33-21-618-001 Pre-conditioning with the APU AMM 21-51-51-000-001 Removal of the Pack Flow-Control Valve AMM 21-51-51-400-001 Installation of the Pack Flow-Control Valve AMM 21-52-00-100-001 Cleaning of the Air Conditioning Pack-Primary Heat
 Exchanger 10HM6 (11HM6) and the Main Heat Exchanger 10HM7 (11HM7) AMM 21-52-00-100-002 Cleaning of the Air Conditioning Pack-Reheater 10HM3 (11HM3) AMM 21-52-00-100-003 Cleaning of the Air Conditioning Pack-Condensor 10HM2
 (11HM2) AMM 21-52-00-780-001 Pressure Drop Test of the Reheater 10HM3 (11HM3) AMM 21-52-00-960-001 Replacement of the Water Injector Nozzle AMM 21-52-16-000-001 Removal of the Water Extractor 10HM8 (11HM8) AMM 21-52-16-400-001 Installation of the Water Extractor 10HM8 (11HM8)
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page A227
 Aug 01/05 CES -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------


AMM  21-52-21-000-001 
AMM  21-52-21-400-001 
AMM  21-52-42-000-001 
AMM  21-52-42-400-001 
AMM  21-61-13-000-001 
AMM  21-61-13-400-001 
AMM  21-61-16-000-001 
AMM  21-61-16-400-002 
AMM  21-61-19-000-001 
AMM  21-61-19-400-002 
AMM  21-61-34-000-001 
AMM  21-61-34-000-002 
AMM  21-61-34-400-001 
AMM  21-61-34-400-002 
AMM  21-61-41-000-001 
AMM  21-61-41-400-001 
AMM  21-61-51-000-003 
AMM  21-61-51-400-003 
AMM  21-61-52-000-003 
AMM  21-61-52-400-003 
AMM  21-63-00-720-001 
AMM  32-69-00-740-001 

ASM 21-61/03 ASM 21-61/04 ASM 21-61/04
 3. Fault Confirmation
__________________Removal of the Air Cycle Machine 10HM1 (11HM1)Installation of the Air Cycle Machine 10HM1 (11HM1)Removal of the Water Injector 20HM (21HM)Installation of the Water Injector 20HM (21HM)Removal of the Water-Extractor Temperature Sensors 11HH and 31HHInstallation of the Water-Extractor Temperature Sensors 11HH and 31HHRemoval of the Pack-Inlet Pressure Sensor 16HH (36HH)Installation of the Pack-Inlet Pressure Sensor 16HH (36HH)Removal of the Pack-Outlet Pneumatic Sensor 10HM10 (11HM10)Installation of the Pack-Outlet Pneumatic Sensor 10HM10 (11HM10)Removal of the Pack Controller (7HH, 27HH)Removal of the Air-Conditioning System Controller (47HH, 57HH)Installation of the Pack Controller (7HH, 27HH)Installation of the Air-Conditioning System Controller (47HH, 57HH)Removal of the Anti-Ice Valve 17HH (37HH)Installation of the Anti-Ice Valve 17HH (37HH)Removal of the Air-Inlet Flap MechanismInstallation of the Air-Inlet Flap MechanismRemoval of the Ram-Air OutletInstallation of the Ram-Air OutletFunctional Test of the Cockpit and Cabin Temperature Control without CFDS/MCDU.BITE Check Landing Gear Control Interface Unit (LGCIU) using MCDU to Ensure that Continuous BITE is Operative
 **ON A/C 001-003, 051-054,
 A. Test NOTE : Do the steps (6) and (7) in less than 120 s, if not, the control
____
 of the zone temperature stabilizes.

 (1) Do the check of the ram-air inlet door mechanism for excessive backlash and of the ram-air outlet door mechanism for damage.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : ALL ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page A228
 Aug 01/05 CES


 (2) Do the pre-conditioning with the APU (Ref. AMM TASK 12-33-21-618-001).

 (3) Make sure that the pack 1 inlet-pressure indication on the ECAM BLEED page is > 20 PSI.

 (4) Set the selectors COCKPIT, FWD CABIN and AFT CABIN, which are installed on the panel 30VU, to HOT for 10 minutes.

 (5) Check of ram-air outlet airflow
 WARNING : THE AIRFLOW CAN BE HOT.

 

_______
 -HOT AIR CAN CAUSE BURNS.

 (a) Do a check to see that there is airflow at the pack 1 ram-air outlet.
 (6) Set the selectors COCKPIT, FWD CABIN and AFT CABIN to COLD.

 (7) On the ECAM BLEED page do a check of the pack 1 discharge temperature (referred to as PDT 1).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调2(58)