R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
E. If the fault continues:
(1) Disconnect the electrical connector (7560VC/A)
(Ref. AMM TASK 21-61-16-000-001).
- make sure that the electrical connector is clean and in the correct condition.
- at the electrical connector (7560VC) do a check for 15VDC from the pack controller primary channel between,
* pins A and C (+15VDC) and,
* pins D and C (-15VDC).
(a) If the voltage is correct:
- replace the SENSOR-PACK INLET PRESSURE (36HH) (Ref. AMM TASK 21-61-16-000-001) and, (Ref. AMM TASK 21-61-16-400-002).
(2) If the fault continues:
- remove the CONTROLLER-PACK 2 TEMP (27HH)
(Ref. AMM TASK 21-61-34-000-001),
- disconnect the electrical connector (31HH/A) from the SENSOR-WATER EXTRACTOR TEMPERATURE (31HH),
- at the electrical connector (31HH/A) do a check for a short circuit between,
* pins E and F and,
* GND and pins E and F.
(a) If there is no short circuit connect the electrical connector (31HH/A).
(b) If there is a short circuit repair the related wiring between,
* connector (31HH/A) pin E and PC 2 connector (27HH/AA) pin 14A,
* connector (31HH/A) pin F and PC 2 connector (27HH/AA) pin 14B.
- connect the electrical connector (31HH/A).
(3) If the fault continues:
- disconnect the electrical connector (28HH/A) from the ACTUATOR-AIR INLET FLAP (28HH),
- at the electrical connector (28HH/A) do a check for a short circuit between,
* pins A and B, A and C, B and C and,
* GND and pins A, B and C.
(a) If there is no short circuit connect the electrical connector (28HH/A).
(b) If there is a short circuit repair the related wiring between,
* connector (28HH/A) pin A and PC 2 connector (27HH/AA) pin 11D,
* connector (28HH/A) pin B and PC 2 connector (27HH/AA) pin 12A,
* connector (28HH/A) pin C and PC 2 connector (27HH/AA) pin 12B.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page A204
201-299, 301-399, Aug 01/05 CES
- connect the electrical connector (28HH/A).
R **ON A/C 401-499,
E. If the fault continues:
(1) disconnect the electrical connector (24HB1/A) from the SENSOR-PRESS, PACK 2 INLET (24HB1).
- make sure that the electrical connector is clean and in the correct condition.
- at the electrical connector (24HB1/A) do a check for 15VDC from pack controller primary channel between,
* pins A and C (+15VDC)
(a) If the voltage is correct:
- replace the SENSOR-PRESS, PACK 2 INLET (24HB1) (Ref. AMM TASK 21-51-13-000-001) and, (Ref. AMM TASK 21-51-13-400-002).
- connect the electrical connector (24HB1/A).
(2) If the fault continues:
- Remove the CONT-AIR COND SYSTEM 2 (57HH)
(Ref. AMM TASK 21-61-34-000-002),
- disconnect the electrical connector (31HH/A) from the SENSOR-WATER EXTRACTOR TEMPERATURE (31HH),
- at the electrical connector (31HH/A) do a check for a short circuit between,
* pins C and D and,
* GND and pins C and D.
(a) If there is no short circuit connect the electrical connector (31HH/A).
(b) If there is a short circuit repair the related wiring between,
* connector (31HH/A) pin C and ACSC2 connector (57HH/AA) pin 4A,
* connector (31HH/A) pin D and ACSC2 connector (57HH/AA) pin 4B.
- connect the electrical connector (31HH/A).
(3) If the fault continues:
- disconnect the electrical connector (28HH/A) from the P2 RAM AIR IN ACTUATOR (28HH),
- at the electrical connector (28HH/A) do a check for a short circuit between,
* pins A and B, A and C, B and C and,
* GND and pins A, B and C.
(a) If there is no short circuit connect the electrical connector (28HH/A).