+ 100 138.5 +/- 0.5
(1) If the resistance values are out of the specified limits:
- replace the SENSOR-COMPRESSOR TEMPERATURE (12HH) (Ref. AMM TASK 21-61-11-000-001) and (Ref. AMM TASK 21-61-11-400-001).
(2) If the fault continues:
- do a check that the resistance of the compressor overheat sensor (15HH) measured between connector A/A and A/B is in these limits (Ref. ASM 21-61/04):
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page 223
201-299, 301-399, Aug 01/05 CES
Temp (Deg.C) OHMS
---------------------------
+ 10 103.9 +/- 0.5
+ 20 107.8 +/- 0.5
+ 30 111.7 +/- 0.5
+ 50 119.4 +/- 0.5
+ 70 127.1 +/- 0.5
+ 100 138.5 +/- 0.5
(a) If the resistance values are out of the specified limits:
- replace the SENSOR-COMPRESSOR OVERHEAT (15HH) (Ref. AMM TASK 21-61-12-000-001) and (Ref. AMM TASK 21-61-12-400-001).
(3) If the fault continues: Do the inspection of the delta P sense lines (Ref. AMM TASK 21-51-00-200-001).
(4) If the fault continues: Replace the SENSOR-PRESSURE (10HB) (Ref. AMM TASK 21-51-11-000-001) and (Ref. AMM TASK 21-51-11-400-001).
(5) If the fault continues:
(a) Swap the SDACIs (1WV1 and 1WV2).(Ref.AMM Task 31-55-34-401)
(b) If this action has solved the problem:
- replace the SDAC which formerly was SDAC#1.
(6) If the fault continues:
(a) Open the CBIs for the Pack Controller 1+2.
(b) Disconnect the Pack ControllerIs. ( Ref.AMM Task 21-61-34-401)
(c) Diconnect the electrical connectors at the FCV#1 (11HB) and FCV#2 (8HB). (Ref.AMM Task 21-51-51-401)
(d) Disconnect the SDAC#1.
(e) Do a check for GND at the SDAC#1 connector AA pin 10D.
(f) Do a check for GND at the SDAC#1 connector AA pin 13B. NOTE : There should be no GND contact
____
(g) If there is no GND contact, reconnect the SDAC#1.
(h) If there is GND contact do a check of the wiring and repair if nessesary.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 004-049, 055-099, 101-149, 151-199, ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page 224
201-299, 301-399, Aug 01/05 CES
R **ON A/C 401-499,
C. If the test confirms the fault:
- do a check that the resistance of the compressor discharge sensor (12HH) measured between connector A/A and A/B is in these limits (Ref. ASM 21-61/04):
Temp (Deg.C) OHMS ---------------------------
+ 10 103.9 +/- 0.5
+ 20 107.8 +/- 0.5
+ 30 111.7 +/- 0.5
+ 50 119.4 +/- 0.5
+ 70 127.1 +/- 0.5
+ 100 138.5 +/- 0.5
(1) If the resistance values are out of the specified limits:
- replace the SENSOR-COMPRESSOR TEMPERATURE (12HH) (Ref. AMM TASK 21-61-11-000-001) and (Ref. AMM TASK 21-61-11-400-001).
(2) If the fault continues: Replace the SENSOR-DELTA P, PACK 1 (23HB2) (Ref. AMM TASK 21-51-11-000-001) and (Ref. AMM TASK 21-51-11-400-001).
(3) If the fault continues:
(a) Swap the SDACIs (1WV1 and 1WV2).(Ref.AMM Task 31-55-34-401)
(b) If this action has solved the problem:
- replace the SDAC which formerly was SDAC#1.
(4) If the fault continues:
(a) Open the CBIs for the ACSC1+2.
(b) Disconnect the ACSC1 and ACSC2 ( Ref.AMM Task 21-61-34-402)
(c) Diconnect the electrical connectors at the FCS#1 (23HB) and FCS#2 (24HB). (Ref.AMM Task 21-51-51-401)
(d) Disconnect the SDAC#1.
(e) Do a check for GND at the SDAC#1 connector AA pin 10D.
(f) Do a check for GND at the SDAC#1 connector AA pin 13B.
NOTE : There should be no GND contact
____
(g) If there is no GND contact, reconnect the SDAC#1.
(h) If there is GND contact do a check of the wiring and repair if nessesary.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 401-499, ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page 225
Aug 01/05 CES
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
D. If the test gives the maintenance message TEST OK, but the FAULT legend on the pushbutton switch AIR COND/PACK 1, which is installed on the panel 30VU, comes on: 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调2(22)