• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 09:16来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 Temp (Deg.C) OHMS ---------------------------
+ 10 18820 +/- 5 %

 + 18 13340 +/- 5 %

 + 25 10000 +/- 5 %

 + 30 8197 +/- 5 %

 + 40 5598 +/- 5 %

 + 50 3903 +/- 5 %


 (1) If the resistance values are out of the specified limits:

 - replace the SENSOR-MIXER UNIT TEMPERATURE COCKPIT (24HK) (Ref. AMM TASK 21-63-16-000-001) and (Ref. AMM TASK 21-63-16-400-001).

 (2) If the fault continues:


 - do a check that the resistance of the mixer-unit temperature cabin-sensor (25HK) measured between connector A/E and A/F and connector A/C and A/D is in these limits (Ref. ASM 21-63/03):
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞21-63-00∞∞∞∞∞∞∞∞∞∞Page 244
 Aug 01/05 CES


 Temp (Deg.C) OHMS

 ---------------------------
+ 10 18820 +/- 5 %

 + 18 13340 +/- 5 %

 + 25 10000 +/- 5 %

 + 30 8197 +/- 5 %

 + 40 5598 +/- 5 %

 + 50 3903 +/- 5 %


 (a) If the resistance values are out of the specified limits:
 - replace the SENSOR-MIXER UNIT TEMPERATURE CABIN (25HK) (Ref. AMM TASK 21-63-16-000-001) and (Ref. AMM TASK 21-63-16-400-001).
 (3) If the fault continues:

 - do a check of the recirculation filter (4012HM) for contamination (Ref. AMM TASK 21-21-41-000-001) and (Ref. AMM TASK 21-21-41-400-001).
 (a) If the filter is clogged:
 - replace the FILTER-RECIRCULATION (4012HM) (Ref. AMM TASK 21-21-41-000-001) and (Ref. AMM TASK 21-21-41-400-001).

 (4) If the fault continues:

 - do a check of the recirculation filter (4013HM) for contamination (Ref. AMM TASK 21-21-41-000-001) and (Ref. AMM TASK 21-21-41-400-001).
 (a) If the filter is clogged:
 - replace the FILTER-RECIRCULATION (4013HM) (Ref. AMM TASK 21-21-41-000-001) and (Ref. AMM TASK 21-21-41-400-001).

 (5) If the fault continues:

 - replace the VALVE-PRESSURE REGULATING (14HK) (Ref. AMM TASK 21-63-52-000-001) and (Ref. AMM TASK 21-63-52-400-001).

 (6) If the fault continues:


 - replace the CONT-AIR COND SYSTEM 1 (47HH) (Ref. AMM TASK 21-61-34-000-002) and (Ref. AMM TASK 21-61-34-400-002).
 C. If the test confirms the fault, with the pushbutton switch HOT AIR, which is installed on the panel 30VU, set to on (with the FAULT and OFF legends off) or OFF:
 - do the operational test of the pack temperature-control system (Ref. AMM TASK 21-61-00-710-001).
 (1) If the test gives a different maintenance message, you can find the related trouble shooting procedure in the applicable Page Block 101.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 401-499, ∞∞21-63-00∞∞∞∞∞∞∞∞∞∞Page 245
 Aug 01/05 CES


R  (2) If the fault continues: 
R  - do a check of the recirculation filter (4012HM) for contamination 
R  (Ref. AMM TASK 21-21-41-000-001) and (Ref. AMM TASK 21-21-41-400-
R  001). 
R  (a) If the filter is clogged: 
R  - replace the FILTER-RECIRCULATION (4012HM) (Ref. AMM TASK 21-21-
R  41-000-001) and (Ref. AMM TASK 21-21-41-400-001). 
R  (3) If the fault continues: 
R  - do a check of the recirculation filter (4013HM) for contamination 
R  (Ref. AMM TASK 21-21-41-000-001) and (Ref. AMM TASK 21-21-41-400-
R  001). 
R  (a) If the filter is clogged: 
R  - replace the FILTER-RECIRCULATION (4013HM) (Ref. AMM TASK 21-21-
R  41-000-001) and (Ref. AMM TASK 21-21-41-400-001). 
R  (4) If the fault continues: 
R  - replace the VALVE-PRESSURE REGULATING (14HK) (Ref. AMM TASK 21-63-
R  52-000-001) and (Ref. AMM TASK 21-63-52-400-001). 
R  (5) If the fault continues: 
R  - replace the CONT-AIR COND SYSTEM 1 (47HH) (Ref. AMM TASK 21-61-34-
R  000-002) and (Ref. AMM TASK 21-61-34-400-002). 
R  (6) If the fault continues: 
R  - replace the CONT-AIR COND SYSTEM 2 (57HH) (Ref. AMM TASK 21-61-34-
R  000-002) and (Ref. AMM TASK 21-61-34-400-002). 
R  **ON A/C ALL
 D. Do the test as given in the Para. 3.A.
 5. Close-up________
 A. Put the aircraft back to its initial configuration.


 TASK 21-63-00-810-822


 Zone Temperature Control Problems in one Zone
 1. Possible Causes
_______________
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 AIR CONDITIONING 空调2(112)