 4. Fault Isolation
_______________
 A. Restricted Pack Controller Fault Isolation
 NOTE : This paragraph is only applicable for:
____
 - Pack Controller Part Number 759A0000-xx

 - Pack Controller Part Number 759C0000-xx


 (1) If the post flight report gives the warning PACK 1 without a maintenance message:

 - swap the PC 1 (7HH) and the PC 2 (27HH) (Ref. AMM TASK 21-61-34-000-001) and (Ref. AMM TASK 21-61-34-400-001).
 (a) If the fault moves with the PC 1:
 - swap back the PC 1 (7HH) and the PC 2 (27HH) (Ref. AMM TASK 21-61-34-000-001) and (Ref. AMM TASK 21-61-34-400-001).

 - replace the CONTROLLER-PACK 1 TEMP (7HH) (Ref. AMM TASK 21-61-34-000-001) and (Ref. AMM TASK 21-61-34-400-001).

 

 (2) If the fault does not move with the PC 1:

 - swap back the PC 1 (7HH) and the PC 2 (27HH) (Ref. AMM TASK 21-61-34-000-001) and (Ref. AMM TASK 21-61-34-400-001).

 - disconnect the electrical connector (11HHA) (Ref. AMM TASK 21-61-13-000-001).

 


 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page A282
 201-299, 301-399, Aug 01/05 CES


 - make sure that the electrical connector is clean and in the correct condition.

 - do a check for voltage at the electrical connector (11HHA) between pins C and D (Ref. ASM 21-61/04).


 (a) If the voltage is not between 4.8VDC and 5.2VDC:
 - disconnect the electrical connector (8HHA) (Ref. AMM TASK 21-61-51-000-001).

 - make sure that the electrical connector is clean and in the correct condition.

 - do a check for voltage again.


 1 If the voltage is between 4.8VDC and 5.2VDC:
_
 - replace the ACTUATOR-AIR INLET FLAP (8HH) (Ref. AMM TASK 21-61-51-000-001) and (Ref. AMM TASK 21-61-51-400-001).

 - connect the electrical connector (8HHA) (Ref. AMM TASK 21-61-51-400-001).


 2 If the voltage is not between 4.8VDC and 5.2VDC:
_
 - connect the electrical connector (8HHA) (Ref. AMM TASK 21-61-51-400-001).

 - repeat para. 4.A.(2).(a) for: connector (9HHA) and the ACTUATOR-AIR OUTLET FLAP (9HH) (Ref. AMM TASK 21-61-52-000-001) and (Ref. AMM TASK 21-61-52-400-001), connector (10HHA) and the VALVE-TURBINE BYPASS (10HH) (Ref. AMM TASK 21-61-53-000-001) and (Ref. AMM TASK 21-61-53-400-001), connector (15HHA) and the SENSOR-COMPRESSOR OVHT (15HH) (Ref. AMM TASK 21-61-12-000-001) and (Ref. AMM TASK 21-61-12-400-001), connector (13HHA) and the SENSOR-PACK OUTLET TEMP (13HH) (Ref. AMM TASK 21-61-15-000-001) and (Ref. AMM TASK 21-61-15-400-001), connector (18HHA) and the SENSOR-BLEED TEMPERATURE (18HH) (Ref. AMM TASK 21-61-17-000-001) and (Ref. AMM TASK 21-61-17-400-001).


 (b) If the voltage is between 4.8VDC and 5.2VDC:
 - replace the SENSOR-WATER EXTRACTOR TEMPERATURE (11HH) (Ref. AMM TASK 21-61-13-000-001) and (Ref. AMM TASK 21-61-13-400-001).

 - connect the electrical connector (11HHA) (Ref. AMM TASK 21-61-13-400-001).


 B. If the fault continues:
 (1) Disconnect the electrical connector (7558VCA)
 (Ref. AMM TASK 21-51-11-000-001) and,

 - make sure that the electrical connectors (7558VC) and (7558VCA) are clean and in a good condition.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞21-61-00∞∞∞∞∞∞∞∞∞∞Page A283
 201-299, 301-399, Aug 01/05 CES (a) At the electrical connector (7558VC) do a check for 15VDC at:


 - pins A and C and D and C, (15VDC from pack controller secondary channel). (Ref. ASM 21-51/01).
 1 If the voltage is correct:
_
 - replace the SENSOR-PRESSURE (10HB). (Ref. AMM TASK 21-51-11-000-001) and (Ref. AMM TASK 21-51-11-400-001).

 - connect the electrical connector (7558VCA). (Ref. AMM TASK 21-51-11-400-001).


 (2) If the fault continues:

 - replace the SENSOR-PACK INLET PRESSURE (16HH) (Ref. AMM TASK 21-61-16-000-001) and (Ref. AMM TASK 21-61-16-400-002).

 (3) If the fault continues: - open the CBIs 1HH (X22), 2HH (Y18), 3HH (X21) and 4HH (Y19),

 - remove the CONTROLLER-PACK 1 TEMP (7HH)
 (Ref. AMM TASK 21-61-34-000-001),


 - disconnect the electrical connector (11HHA) (Ref. AMM TASK 21-61-13-000-001) and,

 - at the electrical connector (11HHA) do a check for a short circuit between:

 * pins C and D and,

 * GND and pins C and D.
 