 (b) Length R The length of sleeve necessary for each type is given in R millimeters. For length code 00, sleeves are supplied in reels of R 1 to 50 m depending on the diameter.
 (c) Diameter code and shrinking tools
 (Ref. Fig. 008)

 B. DAN132
 (1)
 P/N Identification

 DAN132  -02 | | | ------------------- Diameter code ---------------------------- Standard P/N

 (2)
 P/N Characteristics

 (a)
 Temperature Minimum operating temperature is -55 deg.C (-67.00 deg.F). Maximum operating temperature is 220 deg.C (428.00 deg.F). Shrinkage temperature is 175 deg.C (347.00 deg.F).

 (b)
 Diameter code and shrinking tools
 (Ref. Fig. 009)

 

 

 

20-42-12 Page 15

 Shrink Sleeves - Shrinking Tools and Allocation Table for Wires
 E0484
 Figure 008


20-42-12 Page 16
 Apr 01/05
R


 Shrink Sleeves - P/N Characteristics and Shrinking Tools
 DAN132
 Figure 009


20-42-12 Page 17
 Apr 01/05
R


 C. NSA937210
 (Ref. Fig. 010, 011, 012)

 (1)
 P/N identification

 NSA937210 - MB01  00 | | | | | -------------- length (mm) | ------------------- Diameter code ---------------------------- Standard P/N

 (2)
 Characteristics

 (a)
 Temperature Minimum operating temperature is -67 deg.C (-88.60 deg.F). Maximum operating temperature is 250 deg.C (482.00 deg.F). Shrinkage temperature is 327 deg.C (620.60 deg.F).

 (b)
 Length

 ------------------------------| Length code | Length in mm | |-------------|--------------| | 00 | 1200 | |-------------|--------------| | 30 | 30 | |-------------|--------------| | 40 | 40 | |-------------|--------------| | 50 | 50 | |-------------|--------------| | 60 | 60 | ------------------------------

(c)
 Diameter code and shrinking tools (Ref. Fig. 010)

 

 (3)
 Shield stop procedure
 (Ref. Fig. 010)

 

R  (a) Cut and remove the insulation to get the dimension B.
R  (b) Move the shield rearward on the insulation.
R  (c) Install the heat shrink sleeve.
 (d) Heat shrink the sleeve.


20-42-12 Page 18

 Shrink Sleeves - P/N Characteristics and Shrinking Tools
 NSA937210
 Figure 010


20-42-12 Page 19
 Apr 01/05
R


 Shrink Sleeves - Allocation Table for Wires
 NSA937210
 Figure 011


20-42-12 Page 20
 Apr 01/05
R


 Shrink Sleeves - Allocation Table for Wires
 NSA937210 and NSA937493
 Figure 012


20-42-12 Page 21
 Apr 01/05
R


 D. NSA937493
 (Ref. Fig. 012)

 (1)
 P/N Identification

 NSA937493 - 001 | | | ------------------- Diameter code ---------------------------- Standard P/N

 (2)
 P/N Characteristics


 (a) Temperature Minimum operating temperature is -55 deg.C (-67.00 deg.F). Maximum operating temperature is 260 deg.C (500.00 deg.F). Shrinkage temperature is 327 deg.C (620.60 deg.F).
 (b) Length R Supplied by lengths or in cut sleeves, maximum length variation R 20%.
 (c) Diameter code and shrinking tools
 (Ref. Fig. 013)

 

20-42-12 Page 22

 Shrink Sleeves - Shrinking Tools and Allocation Table for Wires
 NSA937493
 Figure 013

 

20-42-12 Page 23

 ____________________________________
END CAPS - DESCRIPTION AND OPERATION
R R R R R  _______1. General End caps are used to isolate the end of a cable that is not connected. High and low temperature end caps installed on aircraft have the codes that follow: - NSA936601 sealing end cap, high temperature NSA936604 sealing end cap, low temperature - ABS0065 heat shrinkable end cap NSA936603 heat shrinkable end cap
 ________________2. Sealing End Caps
 A. NSA936601
R R  (1) P/N identification NSA936601 CA 11 12 | || | | | || | ------------ Max. permitted dia. in 1/10 mm | || | | || ---------------- Min. permitted dia. in 1/10 mm | || | |------------------- Type code | | | -------------------- Cap | --------------------------- Standard P/N
 (2) P/N characteristics
 (a) Temperature Maximum operating temperature is 250 deg.C (482.00 deg.F).
 (b) Color identification (Ref. Fig. 001)
R R  (3) Allocation table (Ref. Fig. 002) This table gives the size of the cap to use for the wire type and gauge.
 