20-33-45 Page 17

 --------------------------------------| CONDUIT | BACKSHELL SIZE CODE |
 | SIZE |--------------------------|
 | CODE | E0074 | E0109 | E0115 |
 |---------|--------|--------|--------|
R | 16 |-----------------|--------|
R | | 22 | -|
R |---------|-----------------|--------|
R | | -| -| 16 |
R | |--------|--------|--------|
R | 20 | -| 20 | -|
R | |-----------------|--------|
R | | 22 | -|
R |---------|-----------------|--------|
R | 24 | 18 | -| 18 |
R |---------|--------|--------|--------|
R | 28 | -| -| 20 |
R |---------|--------|--------|--------|
R | | -| -| 22 |
R | 32 |--------|--------|--------|
R | | -| -| 24 |
R --------------------------------------
R C. Installation procedure For E0074 and E0115 refer to chapter 20-25-52 and 20-33-31. For E0109 and NSA935829 refer to chapter 20-33-31.


20-33-45 Page 1820-33-45 Page 19

 ______________________________________________________5. Backshell for Screened Conduit with Circular Connector
 (Ref. Fig. 011, 012)
 This type of backshell has for example the codes that follow:
 - ABS0280, ABS0281 and ABS0581 backshell for NAS1599 connector type (E0052,
 E0053, E0054) and EN2997.
 - ABS0327 backshell for NAS1599 connector type (E0052, E0053 and E0054).
 - E0075 backshell for NAS1599 connector type (E0039, E0040, E0041, E0052,
 E0053 and E0054).
 A. P/N identification
 ABS0327 V 08 - 06
 ABS0581 V 08 - 06 A
 | | | | | | 
R  | | | | | ----------- Adaptor material type code 
R  | | | | -------------- Conduit size code
 | | | ----------------- Lockwiring type code (for ABS0581) 
R  | | ------------------- Adaptor size code 
R  | ----------------------- Conduit type code
 ----------------------------- Standard P/N
 ABS0280 - 10 - 14
 ABS0281 - 18 - 20
 | | | 
R  | | ---------------- Conduit size code 
R  | --------------------- Backshell size code
 ----------------------------- Standard P/N
 E0075 - 06 - 08 - 3
 | | | |
 | | | -------------- Lockwiring type code 
R  | | ------------------ Adaptor size code 
R  | ----------------------- Conduit size code
 ------------------------------ Standard P/N
 E0805 clamp (for ABS0280 and ABS0281)
 (Ref. Fig. 012)
 E0805 - 01
 | |
 | ------------ Size code
 ------------------- Standard P/N
 B. P/N characteristics
 (1) Temperature
 For ABS0280 and ABS0281
 Minimum operating temperature is -65 deg.C (-85.00 deg.F)
 Maximum operating temperature is +200 deg.C (+392.00 deg.F)
 For ABS0327 and ABS0581
 Minimum operating temperature is -70 deg.C (-94.00 deg.F)
 For ABS0581

 


R Backshell, End Piece and Conduit Fitting - P/N Characteristics and Description ABS0327, ABS0581 and E0075 Figure 011


20-33-45 Page 20

R Backshell, End Piece and Conduit Fitting - P/N Characteristics and Description ABS0280, ABS0281 and E0805 Figure 012


20-33-45 Page 21

 Maximum operating temperature is +235 deg.C (+455.00 deg.F)
 For ABS0327
 Maximum operating temperature is +260 deg.C (+500.00 deg.F)

R (2) Conduit size code
R (a) For ABS0280, ABS0281 and E0075
R ------------------------------------------------------------------------------R | CONDUIT SIZE CODE | BACKSHELL SIZE CODE | R | ------------------------------------|--------------------------------------| R | E0075 | ABS0280 | ABS0281 | E0075 | ABS0280 | ABS0281 | R |-----------|------------|------------|------------|------------|------------| R | 06 | -| -| 08, 10 | -| -| R |-----------|-------------------------|------------|------------|------------| R | -| 08 | -| 08 | 08, 10 | R |-----------|-------------------------|------------|------------|------------| R | 09 | -| -| 10, 12, 14 | -| -| R |-------------------------------------|------------|------------|------------| R | 10 | 12, 14, 16 | 10, 12, 14 | 08, 11, 12 | R |-------------------------------------|------------|------------|------------| R | 12 | 12, 14, 18 | 12 | 12, 15, 16 | R |-------------------------------------|------------|------------|------------| R | 14 | -| 14 | 16, 18, 20 | -| 14, 16, 18 | R |-----------|------------|------------|------------|------------|------------| R | 16 | -| 16 | 18, 20 | -| 14 | R |-----------|------------|------------|------------|------------|------------| R | -| -| 18 | -| -| 20, 21 | R |-----------|------------|------------|------------|------------|------------| R | 20 | -| 20 | 16, 20, 22 | -| 20 | R |-----------|------------|------------|------------|------------|------------| R | -| 22 | 22 | -| 08, 22 | 22 | R |-------------------------------------|------------|-------------------------| R | 24 | 20, 22 | 22 | R |-------------------------------------|------------|-------------------------| R | 28 | -| -| 22, 24 | -| -| R |-----------|------------|------------|------------|------------|------------| R | 32 | -| -| 24 | -| -| R |----------------------------------------------------------------------------|
 