20-33-41 Page 15
R Cable Supports - V shaped Support Type Procedure Figure 008
20-33-41 Page 16
____________
4. U-clamp Type
This type of cable support has the codes that follow : E0435 NSA935501 This type of cable support is used in pressurized areas to attach big diameter bundles.
A. P/N Characteristics
(1)
P/N identification
NSA935501 -S -4
E0435 -A -01 | | | | | ------------ Size code | | | ----------------- Element code | P : Locking plate | | S : Support | --------------------------- Standard P/N
(2)
Temperature For NSA935501 Minimum operating temperature is : -50 deg.C (-58.00 deg.F). Maximum operating temperature is : 105 deg.C (221.00 deg.F).
For E0435
Minimum operating temperature is : -55 deg.C (-67.00 deg.F).
Maximum operating temperature is : 135 deg.C (275.00 deg.F).
(3) Type code R (Ref. Fig. 009)
(a) NSA935501 In relation to the dimension code of the U-clamp type, different dimensions are specified as follows :
20-33-41 Page 17
Cable Supports - U-clamp Type Description
E0435 and NS935501
Figure 009
20-33-41 Page 18
-----------------------------------------------------------------------| ELEMENT CODE | SIZE CODE | HOLE NUMBER | A mm (in.) | |---------------|-------------|---------------|------------------| | | 1 | 2 | 30.48 (1.2000) | | |-------------|---------------|------------------| | S | 2 | 4 | 38.10 (1.5000) | | (old type) |-------------|---------------|------------------| | | 3 | 6 | 45.72 (1.8000) | | |-------------|---------------|------------------| | | 4 | 8 | 53.34 (2.1000) | ------------------------------------------------------------------| S | 4 | 8 | 55 (2.1653) | | (new type) | | | | ------------------------------------------------------------------
B. Procedure R (Ref. Fig. 010)
-Select the applicable U-clamp for the bundle diameter.
-
Install this U-clamp on the structure with a screw.
-
Install the bundles on the U-clamp.
____
NOTE : When bundles are attached to U-clamps NSA935501 S, they must be manufactured such that each bundle or sub-bundle is not more than 35 mm (1.3779 in.) in diameter at the support.
-Install the locking plate and attach with cable tie NSA935401.
20-33-41 Page 19
Cable Supports - U-clamp Type Procedure
NSA935501
Figure 010
20-33-41 Page 20
___________________5. Fairlead Guide Type
This type of cable support has the codes that follow : ABS0678 with ABS0679 E0398 E0557 NSA935511 NSA935512 This type of cable support is used in all areas only to route the feeder cables.
R (Ref. Fig. 011)
A. P/N Characteristics
(1) P/N identification
NSA935511 -01
NSA935512 -01
| | | -------------- Type code | ------------------------ Standard P/N
ABS0678 A 01 E0398 A 01 E0557 A 01
| | | | | --------------- Type code | | | -------------------- Material code | ---------------------------- Standard P/N
(2) Temperature
-
For ABS0678, ABS0679, E0398 and E0557: Minimum operating temperature is -55 deg.C (-67.00 deg.F).
-
For ABS0678 (code A): Maximum operating temperature is 170 deg.C (338.00 deg.F). For ABS0678 (code B) and ABS0679: Maximum operating temperature is 200 deg.C (392.00 deg.F). For E0398 and E0557: Maximum operating temperature is 150 deg.C (302.00 deg.F).
20-33-41 Page 21
Cable Supports - Fairlead Guide Type Description
ABS0678, E0398, E0557, NSA935511 and NSA935512
Figure 011
20-33-41 Page 22
B. Procedure R (Ref. Fig. 012)
-Select the applicable fairlead guide type.
-If necessary, install the support on the structure.
____NOTE : For ABS0678 and NSA935512:
-install the applicable bracket between the cable support and the structure.
-Hold the brackets with rivets or screws on the structure.
-
Install the bobbin NSA935510 on each cable when used, on NSA935511, NSA935512 and E0398 fairlead.
-
Install cables on fairlead guide type.