|---------------- Country and Manufacturer Code ( FRANCE - FILOTEX )
(2) Metric (M) wire types :
(a) ASN/NSA Standard P/Ns Printing must be green as per Federal Standard No. 595a :
-light green (Ref. 34230 or 14272 or 14187) for elements E0261
and E0262.
-dark green (Ref. 14109) for elements E0260, E0263 to E0275,
E0286 to E0292, E0299 and E0300.
The dark green color can vary depending on the insulation color.
The red, black and dark green elements must be marked white.
Marking by laser, the cable will be marked black and the marking
will also be black for purple color optical cables.
20-32-21 Page 25
Apr 01/05
R Printing must be made at 300 mm (11.8110 in.) pitch over the whole length of the cable. It must be of the type : CF 20 X-FA-A. The five letter or figure groups are separated by a dash or a space sufficient to prevent any confusion.
-UP TO 1986 : Group 1 : Two letters identify the wire type (Ref. tables 1-A to 1-Y).
e.g.
CF
Group 2 : Wire gauge.
e.g.
20
Group 3 : One letter indicates the year of manufacture (Ref.
table 3).
e.g.
X (1983)
Group 4 : Two letters indicate the country and the manufacturer
(Ref. table 2).
e.g.
FA (FRANCE/FILECA)
Group 5 : no code : FEP coating, code A : PTFE coating (Ref.
table 4).
Example (up to 1986) :
CF 20 X-FA-A
| | | | | Wire type code | | | | |-------- Code A : PTFE coating Wire per E0261 -------| | | |---------- Country and Manufacturer Code
| | (FRANCE-FILECA) | |------------- Manufacture Year Code (1983) Wire Gauge ----------|
-FROM 1987 TO 1990 : Group 1 : Two letters identify the wire type (Ref. tables 1-A to 1-Y).
e.g.
CF
Group 2 : Wire gauge.
e.g.
20
Group 3 : Two letters indicate the year of manufacture (Ref.
table 3).
e.g.
AB (1987)
Group 4 : Two letters identify the country of manufacture (Ref.
table 2).
e.g.
FR (FRANCE)
Group 5 : One letter identifies the manufacturer (Ref. table
2).
R e.g. A (FILECA) Group 6 : No code : FEP coating, code A : PTFE coating (Ref. table 4). Example (from 1987 to 1990) :
20-32-21 Page 26
| | | | | |
Wire Type Code | | | | | |------- PTFE coating
Wire per E0261 -------| | | | |--------- Manufacturer Code (FILECA)
| | |------------ Country of manufacture (FRANCE)
Wire Gauge ----------| |
|-------------- Manufacture Year Code (1987)
-FROM 1991 Group 1 : Two letters identify the wire type (Ref. tables 1-A to 1-Y).
e.g.
CF
Group 2 : Wire gauge.
e.g.
24
Group 3 : One letter indicates the coating code for laser
marking (Ref. table 4).
e.g.
C (FEP)
Group 4 : Two letters identify the country of manufacture (Ref.
table 2).
e.g.
FR (FRANCE)
Group 5 : One letter identifies the manufacturer (Ref. table
2).
R e.g. A (FILECA) Group 6 : Two numbers indicate the year of manufacture (Ref. table 3).
e.g. 91 (1991)
Example (FROM 1991) :
CF 24 C FR A 91
Wire Type Code | | | | | |
Wire per E0261 -----| | | | | |----------- Year of manufacture
Wire Gauge --------| | | |-------------- Manufacturer Code
| |----------------- Country of manufacture Coating code --------------| (Ref. table 4)
(b) EN Standard P/Ns
-UP TO 1998:
Example:
20-32-21 Page 27
EN2266-005 A 002 P FR A 98
----- -- -- - -- - --
| | | | | | |----- Manufacture Year Code
| | | | | | (Ref. table 3)
| | | | | |--------- Manufacturer Code (Ref. table 2)
| | | | |-------------- Country of Manufacture
| | | | (Ref. table 2)
| | | |------------------ Color code (Ref. table 7 and 8)
| | | ---------------------- Wire gauge code
| | ---------------------------- Code letter for number of cores | (Ref. table 9) |-------------------------------------- Standard P/N 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 ESPM Electrical Standard Practices Manual 2(34)