20-33-33 Page 7

R Miscellaneous Conduit - Description and Installation EN6049-005 Figure 003


20-33-33 Page 8

 (3) Installation procedure
 -Select the applicable size (refer IPC manual or 20-33-30).
 -Cut to the applicable length.
 -Wrap the conduit around the bundle.
 -Make sure that the locking of the gripping strips is done
 correctly. R - Secure with a cable tie NSA935401 at each end of the conduit.


20-33-33 Page 920-33-33 Page 10

R R  D. EN6049-006 and EN6049-007 (Ref. Fig. 004)
R  (1) P/N identification EN6049-006 05 R 5 EN6049-007 05 -5 | | | | | | | --- Color code: 5 = olive green | | | | | ------- Tracer line identification code: | | R = with red tracer line | | Dash (-) = without tracer line | | | ------------ Size code | -------------------- Standard P/N
 (2) P/N characteristics
R R R R R R  (a) Material This type of conduit is made of meta-aramid and: - polyphenylenesulfide (PPS) multifilament fibres (for EN6049-006). - polyetheretherketone (PEEK) multifilament fibres (for EN6049-007. 
R R R R  (b) Temperature Minimum operating temperature is -55 deg.C (-67.00 deg.F). For EN6049-006 Maximum operating temperature is 200 deg.C (392.00 deg.F). For EN6049-007 Maximum operating temperature is 260 deg.C (500.00 deg.F).
 (c) Tracer line identification code This line is used to identify the conduit type with arm system.
 (d) Size code

 


R Miscellaneous Conduit - Description and Installation R EN6049-006 and EN6049-007
 Figure 004


20-33-33 Page 11

 ---------------------------------------------------------------------| Size | Overlap angle | Max bundle Dia. | | code | mesured | mm (in.) | |------|-------------------|----------------------------------------| | 05 | | 1 (0.0393) to 5 (0.1968) | |------| Min 65. |----------------------------------------| | 08 | | 5 (0.1968) to 8 (0.3149) | |------| Max 130. |----------------------------------------| | 13 | | 8 (0.3149) to 13 (0.5118) | |------|-------------------|----------------------------------------| | 19 | Min 70. | 13 (0.5118) to 19 (0.7480) | |------| |----------------------------------------| | 25 | Max 110. | 19 (0.7480) to 25 (0.9842) | ---------------------------------------------------------------------
(3) Installation procedure
 -Select the applicable size (refer to the IPC manual or to 20-33-30).
 -Cut to the applicable length.
 -Wrap the conduit around the bundle.
 -For easier installation, you can use the ROUNDIT 5-19 tool (Refer
 to chapter 20-25-52 for the detailed procedure). R - Secure with a cable tie NSA935401 at each end of the conduit.


20-33-33 Page 12

 ________________
3. (Closed) conduit R (Ref. Fig. 005)
 A. ABS0125
 (1)
 P/N identification

 ABS0125  03 | | | ------------ Size code | -------------------- Standard P/N

 (2)
 P/N characteristics

 (a)
 Temperature Minimum operating temperature is -40 deg.C (-40.00 deg.F). Maximum operating temperature is 155 deg.C (311.00 deg.F).

 (b)
 Size code -----------------------------------------------| Size | Interior dia. D | | code | mm (in.) | |-------------|-------------------------------| | 03 | 3 (0.1181) | |-------------|-------------------------------| | 04 | 4 (0.1574) | |-------------|-------------------------------| | 05 | 5 (0.1968) | |-------------|-------------------------------| | 06 | 6 (0.2362) | |-------------|-------------------------------| | 08 | 8 (0.3149) | |-------------|-------------------------------| | 10 | 10 (0.3937) | -----------------------------------------------

 

(3)
 Installation procedure


 -Select the applicable size (refer to the IPC manual or to 20-33-30).
 -Cut to the applicable length.
 -Slide the applicable length of conduit under the harness. R - Secure with a cable tie NSA935401 at each end of the conduit.


20-33-33 Page 13

R Miscellaneous conduit - P/N Characteristics ABS0125 Figure 005


20-33-33 Page 14

 B. E0389, E0502 and E0559 R (Ref. Fig. 006)
 (1) P/N identification
 E0389 V 06
 E0502 V 05
 E0559 A 06

 | | | | | ---------- Size code | | | --------------- Color code: E0389 and E0502: V = Olive green | E0559: A = Natural color | --------------------- Standard P/N
 (2) P/N characteristics
 (a) Temperature
 -
For E0389 and E0502 Minimum operating temperature is -60 deg.C (-76.00 deg.F). Maximum operating temperature is 240 deg.C (464.00 deg.F).

 -
For E0559 Minimum operating temperature is -60 deg.C (-76.00 deg.F). Maximum operating temperature is 200 deg.C (392.00 deg.F).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 ESPM Electrical Standard Practices Manual 2(63)