20-33-33 Page 7
R Miscellaneous Conduit - Description and Installation EN6049-005 Figure 003
20-33-33 Page 8
(3) Installation procedure
-Select the applicable size (refer IPC manual or 20-33-30).
-Cut to the applicable length.
-Wrap the conduit around the bundle.
-Make sure that the locking of the gripping strips is done
correctly. R - Secure with a cable tie NSA935401 at each end of the conduit.
20-33-33 Page 920-33-33 Page 10
R R D. EN6049-006 and EN6049-007 (Ref. Fig. 004)
R (1) P/N identification EN6049-006 05 R 5 EN6049-007 05 -5 | | | | | | | --- Color code: 5 = olive green | | | | | ------- Tracer line identification code: | | R = with red tracer line | | Dash (-) = without tracer line | | | ------------ Size code | -------------------- Standard P/N
(2) P/N characteristics
R R R R R R (a) Material This type of conduit is made of meta-aramid and: - polyphenylenesulfide (PPS) multifilament fibres (for EN6049-006). - polyetheretherketone (PEEK) multifilament fibres (for EN6049-007.
R R R R (b) Temperature Minimum operating temperature is -55 deg.C (-67.00 deg.F). For EN6049-006 Maximum operating temperature is 200 deg.C (392.00 deg.F). For EN6049-007 Maximum operating temperature is 260 deg.C (500.00 deg.F).
(c) Tracer line identification code This line is used to identify the conduit type with arm system.
(d) Size code
R Miscellaneous Conduit - Description and Installation R EN6049-006 and EN6049-007
Figure 004
20-33-33 Page 11
---------------------------------------------------------------------| Size | Overlap angle | Max bundle Dia. | | code | mesured | mm (in.) | |------|-------------------|----------------------------------------| | 05 | | 1 (0.0393) to 5 (0.1968) | |------| Min 65. |----------------------------------------| | 08 | | 5 (0.1968) to 8 (0.3149) | |------| Max 130. |----------------------------------------| | 13 | | 8 (0.3149) to 13 (0.5118) | |------|-------------------|----------------------------------------| | 19 | Min 70. | 13 (0.5118) to 19 (0.7480) | |------| |----------------------------------------| | 25 | Max 110. | 19 (0.7480) to 25 (0.9842) | ---------------------------------------------------------------------
(3) Installation procedure
-Select the applicable size (refer to the IPC manual or to 20-33-30).
-Cut to the applicable length.
-Wrap the conduit around the bundle.
-For easier installation, you can use the ROUNDIT 5-19 tool (Refer
to chapter 20-25-52 for the detailed procedure). R - Secure with a cable tie NSA935401 at each end of the conduit.
20-33-33 Page 12
________________
3. (Closed) conduit R (Ref. Fig. 005)
A. ABS0125
(1)
P/N identification
ABS0125 03 | | | ------------ Size code | -------------------- Standard P/N
(2)
P/N characteristics
(a)
Temperature Minimum operating temperature is -40 deg.C (-40.00 deg.F). Maximum operating temperature is 155 deg.C (311.00 deg.F).
(b)
Size code -----------------------------------------------| Size | Interior dia. D | | code | mm (in.) | |-------------|-------------------------------| | 03 | 3 (0.1181) | |-------------|-------------------------------| | 04 | 4 (0.1574) | |-------------|-------------------------------| | 05 | 5 (0.1968) | |-------------|-------------------------------| | 06 | 6 (0.2362) | |-------------|-------------------------------| | 08 | 8 (0.3149) | |-------------|-------------------------------| | 10 | 10 (0.3937) | -----------------------------------------------
(3)
Installation procedure
-Select the applicable size (refer to the IPC manual or to 20-33-30).
-Cut to the applicable length.
-Slide the applicable length of conduit under the harness. R - Secure with a cable tie NSA935401 at each end of the conduit.
20-33-33 Page 13
R Miscellaneous conduit - P/N Characteristics ABS0125 Figure 005
20-33-33 Page 14
B. E0389, E0502 and E0559 R (Ref. Fig. 006)
(1) P/N identification
E0389 V 06
E0502 V 05
E0559 A 06
| | | | | ---------- Size code | | | --------------- Color code: E0389 and E0502: V = Olive green | E0559: A = Natural color | --------------------- Standard P/N
(2) P/N characteristics
(a) Temperature
-
For E0389 and E0502 Minimum operating temperature is -60 deg.C (-76.00 deg.F). Maximum operating temperature is 240 deg.C (464.00 deg.F).
-
For E0559 Minimum operating temperature is -60 deg.C (-76.00 deg.F). Maximum operating temperature is 200 deg.C (392.00 deg.F).