R ____
NOTE : The tool CV1981-42V-960W is not more procurable. R Instead of this tool, to work on aircraft, we recommend to use an R insulating transformer (ref : 42517 - Manufacturer : LEGRAND or R equivalent) with a power of 1600VA with following tools : R - CV1981-230V-1600WPID (European version) R - CV1981-120V-1600W-CANPIDF (US version) R - HG2000E R - HG3000SLE
 You can use different reflectors to agree with the sleeve to be
 shrunk: R PR12, PR13, PR13C,etc...
 B. Type 500 Generator The heat gun has a removable handle and base assembly that gives more than one operating position. There is an OFF-COLD-HOT selector switch.
 ---------------------------------------------------------------------------
| MANUFACTURER | MODEL | SUPPLY(AC) | POWER | Temp. Range | COLOR |
 | | | V | W | deg.C (deg.F) | |
 |--------------|--------|------------|--------|---------------------|-------|
 | | 500A | 110 | 1500 | 500-700(932-1292) | GREEN |
 | RAYCHEM | 502 | 220 | 1500 | 500-700(932-1292) | GREEN |
 | | 750 | 110 | 2000 | 750-1000(1382-1832) |YELLOW |
 | | 752 | 220 | 2000 | 750-1000(1382-1832) |YEllOW |
 ---------------------------------------------------------------------------
RAYCHEM no longer make these Type 500 heat guns but you can continue to
 use them.
 They are replaced by Type 1500 heat guns.

 

20-25-31 Page 3

 C. Type 1500 generator These can have 900W or 1100W heating elements. Switch position agree with the following power output:
 ----------------------------------------------------------------------------| | | | | SWITCH POSITION | | MANUFACTURER | P/N | SUPPLY | MODEL |---------------------------| | | | V | | 1 |  2  | 3  |  4  | 5 | |---------------|-------|---------|------------ |-----|-----|----|-----|----| | | | | TG119/900A | |400W |500W|900W | | | | 1501A | 110(AC) |-------------|COLD |-----|----|-----|COLD| | | | | TG119/1100A | |200W |900W|1000W| | | RAYCHEM |-------|---------|-------------|-----|-----|----|-----|----| | | | | TG119/900A | |400W |500W|900W | | | | 1502A | 220(AC) |-------------|COLD |-----|----|-----|COLD| | | | | TG119/1100A | |200W |900W|1000W| |
 ---------------------------------------------------------------------------
R
R Different reflectors are used to agree with the sleeve to be shrunk:
R PR12, PR13, PR13C,etc...

R D. Type HL/HG STEINEL generator (Ref. Fig. 002) R There are four generators in this range.
R -------------------------------------------------------------------------------R | | |SUPPLY |POWER | SELECTOR POSITION | R | MANUFACTURER| P/N | | |---------------------------| R | | | (V) | (W) | 0 | I | II | R |-------------|--------------------|-------|------|---|------ -------|--------| R | | HL2000P-220V-2000W | 220 | 2000 | | | | R | RAYCHEM |--------------------|-------|------| | | | R | | HL1802E-230V-2000W | 230 | 2000 | | | | R |-------------|--------------------|-------|------|OFF| INTERMEDIATE |MAXIMUM | R | | HG2000E-230V-2000W | 230 | 2000 | | | | R | STEINEL |--------------------|-------|------| | | | R | |HG3000SLE-230V-2000W| 230 | 2000 | | | | R -------------------------------------------------------------------------------
Different reflectors are used to agree with the sleeve to be shrunk: PR12, PR13, PR13C etc.
 _________________________
3. Reflector Characteristics (Ref. Fig. 003, 004) To make sure that the supply of heat is constant around the heat shrinkable sleeves or moulding, the heating equipment has a nozzle attachment (reflector). Make sure that the dimensions and shape of the reflector are applicable for the related application.


20-25-31 Page 4

R Shrinking Tools - Hot Air Generators R HL1802E, HL2000, HG2000 and HG3000 Figure 002


20-25-31 Page 5

R Shrinking Tools - Reflectors allocation table R PR 12 to PR 13C R Figure 003


20-25-31 Page 6

R Shrinking Tools - Hot Air Generator Reflectors R PR 21 to PR 26 R Figure 004


20-25-31 Page 7

 ___________________4. Operating Procedure
 A. Temperature
 The minimum temperature of shrinking is :

 -------------------------------------------------------------------| P/N | TYPE | Temperature deg. C (deg. F) | |-----------------------------------------------------------------| | ABS0061 | Shrink Sleeve | 125 deg. C (275 deg. F) | |-----------------------------------------------------------------| | E0126 | Shrink Sleeve | 120 deg. C (248 deg. F) | |-----------------------------------------------------------------| | E0484 | Shrink Sleeve | 100 deg. C (212 deg. F) | |-----------------------------------------------------------------| | E0718 | Shrink Sleeve | 175 deg. C (347 deg. F) | |-----------------------------------------------------------------| | NSA936603 | End Cap | 135 deg. C (275 deg. F) | |-----------------------------------------------------------------| | NSA937201 | Identification Sleeve | 120 deg. C (248 deg. F) | |-----------------------------------------------------------------| | NSA937210 | Shrink Sleeve | 327 deg. C (620.6 deg. F) | |-----------------------------------------------------------------| | NSA937211 | Shrink Sleeve | 120 deg. C (248 deg. F) | |-----------------------------------------------------------------| | NSA937493 | Shrink Sleeve | 327 deg. C (620.6 deg. F) | |-----------------------------------------------------------------| | NSA937494 | Shrink Sleeve | 175 deg. C (347 deg. F) | |-----------------------------------------------------------------| | NSA937502 | Shrink Sleeve | 135 deg. C (275 deg. F) | -------------------------------------------------------------------
 