20-33-32 Page 4
R Screened Convoluted Conduit - P/N Characteristics and Description
R ABS0330/0492/0510/0511/0631/887B and C, E0469, E0560 and NSA935805T/806T Figure 002
20-33-32 Page 520-33-32 Page 620-33-32 Page 7
(1) Temperature
R - For ABS0492, ABS0510, ABS0511, ABS0887, E0469, E0560, NSA935805T
R and NSA935806T:
Minimum operating temperature is -55 deg.C (-67.00 deg.F)
- For ABS0330, ABS0631:
Minimum operating temperature is -70 deg.C (-94.00 deg.F)
R - For ABS0492, ABS0510, ABS0511 and ABS0887C:
Maximum operating temperature is 165 deg.C (329.00 deg.F)
R - For ABS0330, ABS0631, ABS0887B, E0469, E0560, NSA935805T and
R NSA935806T:
Maximum operating temperature is 260 deg.C (500.00 deg.F)
R (2) Diameter type code (only for ABS0887, E0469 and E0560)
R ----------------------------------------------------
R | DIAMETER TYPE CODE | DIAMETER INTERIOR mm (in.)|
R |---------------------|----------------------------|
R | 04 * | 3 (0.118) |
R |--------------------------------------------------|
R | 06 | 4,6 (0.181) |
R |--------------------------------------------------|
R | 09 | 7 (0.275) |
R |--------------------------------------------------|
R | 10 | 7,6 (0.299) |
R |--------------------------------------------------|
R | 12 | 8,2 (0.322) |
R |--------------------------------------------------|
R | 14 | 10,8 (0.425) |
R |--------------------------------------------------|
R | 16 | 12,3 ( 0.484) |
R |--------------------------------------------------|
R | 20 | 15,6 (0.614) |
R |--------------------------------------------------|
R | 24 | 19 (0.748) |
R |--------------------------------------------------|
R | 28 | 21,8 (0.858) |
R |--------------------------------------------------|
R | 32 | 24,5 (0.964) |
R |--------------------------------------------------|
R | 40 ** | 31,4 (1.236) |
R ----------------------------------------------------
R * For E0469 and E0560 only
R ** For ABS0887 only
R
C. Procedures
(1) Drain holes
(Ref. Fig. 003)
R ____NOTE : You can only make drain holes before installation of the
R conduit on the bundle and before installation of the end
R assembly.
- Only for conduit with halar sheath (step 1):
R Use a soldering iron to cut a 20 mm (0.7874 in.) long window in the
R E-CTFE braid.
R The window width must not exceed 30% of the protective conduit
R circumference.
R - Insert a plastic rod in the conduit until it is behind the hole
R position.
R In the necessary hole position, use a blunt needle to slide the
R braid aside with circular movements (step 2).
R - Make sure that you strike a "crest" of the convoluted hose below.
R - Punch a hole in the convoluted hose with punch pliers or equivalent