(b) Size code For E0502 -----------------------------------------------| Size | Interior dia. D | | code | mm (in.) | |-------------|-------------------------------| | 05 | 2 (0.0787) to 8 (0.3149) | |-------------|-------------------------------| | 10 | 5 (0.1968) to 15 (0.5905) | |-------------|-------------------------------| | 15 | 8 (0.3149) to 24 (0.9448) | |-------------|-------------------------------| | 25 | 12 (0.4724) to 36 (1.4173) | |-------------|-------------------------------| | 40 | 22 (0.8661) to 60 (2.3622) | -----------------------------------------------
20-33-33 Page 15
R Miscellaneous Conduit - P/N Characteristics and Installation E0389, E0502 and E0559 Figure 006
20-33-33 Page 16
For E0389
-----------------------------------------------| Size | Interior dia. D | | code | mm (in.) | |-------------|-------------------------------| | 02 | 1 (0.0393) to 2 (0.0787) | |-------------|-------------------------------| | 04 | 2 (0.0787) to 4 (0.1574) | |-------------|-------------------------------| | 06 | 4 (0.1574) to 8 (0.3149) | |-------------|-------------------------------| | 08 | 6 (0.2362) to 12 (0.4724) | |-------------|-------------------------------| | 10 | 8 (0.3149) to 16 (0.6299) | |-------------|-------------------------------| | 15 | 10 (0.3937) to 20 (0.7874) | |-------------|-------------------------------| | 20 | 12 (0.4724) to 24 (0.9448) | |-------------|-------------------------------| | 25 | 15 (0.5905) to 30 (1.1811) | |-------------|-------------------------------| | 30 | 20 (0.7874) to 40 (1.5748) | -----------------------------------------------
For E0559
-----------------------------------------------
| Size | Interior dia. D |
| code | mm (in.) |
|-------------|-------------------------------|
| 06 | 3 (0.1181) to 8 (0.3149) |
|-------------|-------------------------------|
| 12 | 7 (0.2755) to 16 (0.6299) |
|-------------|-------------------------------|
| 18 | 14 (0.5511) to 28 (1.1023) |
-----------------------------------------------
(3) Installation procedure R (Ref. Fig. 006)
-Select the applicable size (the conduit size code depends on the harness diameter which must correspond to 80% of the size code).
-Cut the conduit to the applicable length. This length corresponds to the length of the harness to be protected (L), plus 50 mm (1.9685 in.) at each end.
-Position the conduit on the harness.
-Crease the conduit to bring it to 20 mm (0.7874 in.) at each end less the length "L".
20-33-33 Page 17
-Tie with lacing tape NSA8420-1 or -2 10 mm (0.3937 in.) from both ends of the conduit.
-Fold back the conduit over each end to its length "L".
-Attach the conduit end ligature with cable tie NSA935401 or lacing tape NSA8420
____
NOTE : If one end must be held in the backshell of a connector, the folded length of the conduit must be greater by 20 to 30 mm. This additional length must be allowed for when the conduit is cut to length and when the end is shaped. The connector backshell grip is sufficient for cable tie NSA935401 to be removed.
20-33-33 Page 18
R C. EN6049-003 and EN6049-004 R (Ref. Fig. 007)
(1)
P/N identification
EN6049-003 02 5
EN6049-004 02 5
| | | | | ---------- Color code: 5 = olive green | | | --------------- Size code | ----------------------- Standard P/N
(2)
P/N characteristics
(a)
Temperature Minimum operating temperature is -55 deg.C (-67.00 deg.F). Maximum operating temperature is 240 deg.C (464.00 deg.F).
(b)
Size code For EN6049-003 -----------------------------------------------| Size | Interior dia. D | | code | mm (in.) | |-------------|-------------------------------| | 02 | 2 (0.0787) | |-------------|-------------------------------| | 04 | 4 (0.1574) | |-------------|-------------------------------| | 06 | 6 (0.2362) | |-------------|-------------------------------| | 08 | 8 (0.3149) | |-------------|-------------------------------| | 10 | 10 (0.3937) | |-------------|-------------------------------| | 15 | 15 (0.5905) | |-------------|-------------------------------| | 20 | 20 (0.7874) | |-------------|-------------------------------| | 25 | 25 (0.9842) | |-------------|-------------------------------| | 30 | 30 (1.1811) | -----------------------------------------------
20-33-33 Page 19
R Miscellaneous Conduit - P/N Characteristics and Installation EN6049-003 and EN6049-004 Figure 007
20-33-33 Page 20
For EN6049-004
-----------------------------------------------
| Size | Interior dia. D |
| code | mm (in.) |