No specific fiber-bristled brush No specific access platform 3.0 m (9 ft. 10 in.) No specific Torque Wrench : range 0.00 to 1.20 m.daN
 (0.00 to 9.00 lbf.ft) No specific Torque Wrench : range 0.20 to 3.60 m.daN
 (2.00
 to 26.00 lbf.ft) 98A49107504001 1 PROTECTOR - THREADS, APU MOUNTING BOLTS

 B.
 Consumable Materials


 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 05-002  USA MIL-P-8116 PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00)
 Material No. 05-027  USA MIL-L-81309 RUST INHIBITOR(FOR CORROSION USE 15-004) (Ref. 20-31-00)
 Material No. 11-001  USA MIL-D-16791 TYPE I DETERGENT (Ref. 20-31-00)


 C. Expendable Parts -------------------------------------------------------------------------------
FIG.ITEM --------- |DESIGNATION ---------------------------------------- |IPC-CSN------------------------------
1  cotter pins  49-12-04 02 -110
 1  cotter pins  49-12-04 02A-110
 7  cotter pins  49-12-04 02 -120
 7  cotter pins  49-12-04 02A-120
 18  cotter pin  49-12-04 02 -110
 18  cotter pin  49-12-04 02A-110
 D. Referenced Information
 ------------------REFERENCE  -------------------------------DESIGNATION ------------------------------

-------------------------------------------------------------------------------
20-28-00-912-004  Electrical Bonding of Components With Conductive Bolts and Screws and Bonding Straps in the Fuselage and in the Wings (this does not include the tanks)-
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
 Configuration before Maintenance Action 49-00-00-080-001 Removal of the APU Hoist Tool (APS 3200) 52-41-00-010-001 Open the APU Doors for Access 52-41-00-410-001 Close the APU Doors after Access 52-41-21-000-001 Removal of the APU Access Door 315AL 52-41-22-000-001 Removal of the APU Access Door 316AR and the related
 Door Mechanism 49-12-51-991-002 Fig. 401
 3. Job Set-up
__________
 Subtask 49-12-51-860-052
 A. Aircraft Maintenance Configuration
 (1)
 Make sure that the warning notices is on panel 25VU to tell persons not to start the APU.

 (2)
 Make sure that the ground service network is energized (Ref. TASK 24-41-00-861-002).

 (3)
 Make sure that the hydraulic systems are depressurized (Ref. TASK 29-00-00-864-001).

 (4)
 Make sure that the access platform is in position below the access doors 315AL and 316AR.

 (5)
 Make sure that the APU access doors 315AL, 316AR are open (Ref. TASK 52-41-00-010-001) or removed (Ref. TASK 52-41-21-000-001) and (Ref. TASK 52-41-22-000-001).

 


 (6)
 Make sure that the light switch 11LJ is set to on. Subtask 49-12-51-865-054

 B.
 Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged


 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41
 4. Procedure
_________
 (Ref. Fig. 401/TASK 49-12-51-991-002) Subtask 49-12-51-210-053
 A. Preparation for Installation
 (1)
 Clean the tie-rods (5), (10) and (11) and the vibration isolator (12) with solvent CLEANING AGENTS (Material No. 11-001) and a fiber-bristled brush. condition.

 (2)
 Do a check and make sure that the tie-rods (5), (10) and (11) are in correct condition.

 (3)
 If the tie-rods and/or the vibration isolator are damaged, replace them if necessary.

 (4)
 Clean and examine the attachment brackets, the APU mount-bracket (14) and the structure for damage and replace if nescessary.

 


 Subtask 49-12-51-420-051
 B. Installation of the Vibration Isolator
 CAUTION : WHEN YOU REMOVE (INSTALL) THE APU, DISENGAGE (ENGAGE) ALL THE
_______ VIBRATION ISOLATORS AT THE SAME TIME FROM THE APU MOUNT BRACKETS. IF YOU DISENGAGE (ENGAGE) THEM ONE AFTER THE OTHER, THE LOADS WILL NOT BE EQUAL. THIS WILL CAUSE DAMAGE TO THE TIE RODS.
 (1) Protective Treatment
 WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL
_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
 
中国航空网 www.aero.cn