the phase lead with the yellow label 8XS-T2 to the terminal stud T2.
-
the phase lead with the blue label 8XS-T3 to the terminal stud T3.
-
the phase lead with the white label 8XS-N to the terminal stud
N.
NOTE : Make sure that the terminals of the generator (80) and
____ ring terminals of the phase leads (82) are clean and not damaged.
NOTE : Make sure that the washers are loose at the lower,
____ non-threaded portion of the terminal studs.
(f)
TORQUE the nuts (83) to between 2.3 and 2.5 m.daN (16.96 and
18.43 lbf.ft).
(g)
Lubrication of the bolts (70).
WARNING : USE THE CORRECT PERSONAL PROTECTION.
_______ OIL CAN HAVE ADDITIVE CALLED TRICRESYL PHOSPHATE IN IT. THIS CHEMICAL IS AN ASPHYXIANT, IT IS POISONOUS AND CAN BE ABSORBED THROUGH THE SKIN. USE CARE WHEN ENGINE OIL IS DRAINED. HOT OIL CAN POSSIBLY CAUSE BAD BURNS.
1 Lubricate the bolts (70) with OILS (Material No. 03-002).
_
(h)
Install the cover plate (71), the washers (84) and the bolts (70).
(i)
TORQUE the bolts (70) to between 0.43 and 0.47 m.daN (38.05 and
41.59 lbf.in).
(5) Connection of the Starter Motor (Ref. Fig. 403/TASK 49-11-11-991-009)
CAUTION : REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU
_______ CONNECT THE ELECTRICAL WIRES. INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
(a)
Remove and discard the cable-ties which temporarily attached the starter motor cables (74), (77) and (78) to the FWD LH tie rod.
(b)
Remove the blanking caps from ring terminals of the starter cables (74), (77) and (78).
(c)
Remove the nuts (72), (75), the washers (73) and (76) which are temporarily installed on the terminal studs.
NOTE : Make sure that the terminal studs, nuts and washers are in
____ correct condition. Replace any item found not in correct condition.
NOTE : If it is necessary, carefully pull the positive electrical
____ lead from C80 until you can attach the cable correctly.
NOTE : The positive electrical leads (77 and 78) must be directly
____ in conter with the starter motor copper strip, before installation of the washer (76) and the nut (75).
(d) Install the positive starter cable (78), the monitoring cable (77), the washer (76) and the nut (75) to the positive terminal stud.
NOTE : The positive starter cable is identified through the label
____
reading 8KAPOS.
(e) Install the negative starter cable (74), the washer (73) and the nut (72) to the negative terminal stud.
NOTE : The negative starter cable is identified through the label
____
reading 8KANEG.
(f)
TORQUE the nut (75) of the positive starter cable to between 0.85 and 0.90 m.daN (75.22 and 79.64 lbf.in).
(g)
TORQUE the nut (72) of the negative starter cable to between 0.56 and 0.62 m.daN (49.55 and 54.86 lbf.in).
(h)
Push the rubber cover (86) back over the electrical connections.
(6)
Connection of the Electrical Harness (Ref. Fig. 402/TASK 49-11-11-991-012)
(a)
Remove and discard the cable-ties which temporarily attach the electrical connectors (50) P1, (51) P2 and (55) P3 to the APU.
(b)
Remove the blanking caps from the connectors.
(c)
Make sure the connectors are clean and in a correct condition.
(d)
Remove the temporarily installed bolt (61) and nut (62) from the clamp (60) on the FWD RH tie rod.
(e)
Put the clamp (63) in position on the clamp (60), install and tighten the bolt (61) and the nut (62).
(f)
Remove the temporarily installed bolt (56) and the washer (57) from the bracket (59) at the RH side of the APU compartment.
(g)
Make sure that the nut clip on the bracket (59) is in the correct position.
(h)
Put the clamp (58) into position, install the washer (57) and the bolt (56), tighten the bolt (56).
(i)
Install the connector (50) P1 to the correct connector on the forward firewall.
(j)
Remove the temporarily installed bolts (54) and spacers (52) from the brackets on the APU compartment front firewall.
(k)
Make sure that the nut clips on the brackets (on the front firewall) are in the correct position.