R EFF : 001-049, 101-105, 107-107, 151-199, 49-16-00Page 701 201-210, Config-2 Aug 01/05
CES
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 11-011 USA AMS 1533 EXTERIOR AIRCRAFT CLEANER. GEL TYPE (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action 29-14-00-614-002 Pressurization of the Hydraulic Reservoirs through
the Ground Connector 49-00-00-860-008 APU Start by External Power (131-9(A)) 49-00-00-860-009 APU Shutdown by External Power (131-9(A)) 52-41-00-010-001 Open the APU Doors for Access 52-41-00-410-001 Close the APU Doors after Access
3. Job Set-up
__________
Subtask 49-16-00-860-062
A. Aircraft Maintenance Configuration
(1)
Energize the ground service network
(Ref. TASK 24-42-00-861-001).
(2)
On the panel 25VU, press the APU MASTER SW pushbutton switch then make sure that the APU air intake flap has moved to the fully open position.
(3)
Put a warning notice in the cockpit to tell persons not to start the APU.
(4)
Make sure that hydraulic systems are depressurized
(Ref. TASK 29-00-00-864-001).
R EFF : 001-049, 101-105, 107-107, 151-199, 49-16-00Page 702 201-210, Config-2 Aug 01/05
CES Subtask 49-16-00-865-079
B. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41
Subtask 49-16-00-010-065
C. Get Access
(1)
Put the access platform in position below the APU access doors 315AL and 316AR.
(2)
Open the APU access doors 315AL and 316AR (Ref. TASK 52-41-00-010-001).
(3)
Set the light SW 11LJ to the ON position.
4. Procedure
_________
Subtask 49-16-00-110-052
A. Cleaning of the APU Air Intake System.
(1) Make an inspection of the air intake duct and the APU Doors 315AL and 316AR for grease and oil contamination.
-If you find any contamination do the following procedure:
(a)
Clean the APU air intake flap, the air intake duct internally and the APU Doors. Use pure CLEANING AGENTS (Material No. 11-011) as a spray with a pressure of 2-3 bar (29-43.5 psi) on:
-
the inner walls of the installed air intake duct,
-
the inner walls of the air intake housing including intake flap,
-
the installed APU Doors.
(b)
Let the cleaning agent stay on the surfaces for 20 mins. to complete the cleaning process.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER2(148)