(3)
Make sure that the warning notices is on panel 25VU to tell persons not to start the APU.
(4)
Make sure that hydraulic systems are depressurized
(Ref. TASK 29-00-00-864-001).
(5)
Make sure that the access platform is in position below the access doors 315AL and 316AR.
(6)
Make sure that the APU access doors 315AL, 316AR are open (Ref. TASK 52-41-00-010-001) or removed (Ref. TASK 52-41-21-000-001) and (Ref. TASK 52-41-22-000-001).
(7)
Make sure that the LIGHT SW 11LJ is set to the ON position.
Subtask 49-12-51-865-057
B.
Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41
4. Procedure
_________
**ON A/C 001-049, 101-105, 201-203,
(Ref. Fig. 401/TASK 49-12-51-991-003)
R EFF : 001-049, 101-105, 107-107, 151-199, 49-12-51Page 410 201-210, Config-2 Aug 01/05
CES
R **ON A/C 107-107, 151-199, 204-210,
(Ref. Fig. 401A/TASK 49-12-51-991-003-A) R **ON A/C 001-049, 101-105, 107-107, 151-199, 201-210,
Subtask 49-12-51-210-055
A. Preparation for Installation
(1)
Clean the tie-rods (5), (10) and (11) and the vibration isolator (12) with solvent CLEANING AGENTS (Material No. 11-001) and a fiber-bristled brush.
(2)
Do a check and make sure that the tie-rods (5), (10) and (11) are in correct condition.
(3)
If the tie-rods and/or the vibration isolator are damaged, replace them if necessary.
(4)
Clean and examine the attachment brackets, the APU mount-bracket (14) and the structure for damage and replace if nescessary.
**ON A/C 001-049, 101-105, 201-203,
Subtask 49-12-51-420-056
B. Installation of the Vibration Isolator CAUTION : WHEN YOU REMOVE (INSTALL) THE APU, DISENGAGE (ENGAGE) ALL THE
_______ VIBRATION ISOLATORS AT THE SAME TIME FROM THE APU MOUNT BRACKETS. IF YOU DISENGAGE (ENGAGE) THEM ONE AFTER THE OTHER, THE LOADS WILL NOT BE EQUAL. THIS WILL CAUSE DAMAGE TO THE TIE RODS.
(1)
Apply SPECIAL MATERIALS (Material No. 05-002) to all mating surfaces. Do not apply it to the bonding straps.
(2)
If removed, install the tie-rods (5), (10) and (11).
(a) Install the bolts (15), the washers (16) and the castle nuts (17).
R EFF : 001-049, 101-105, 107-107, 151-199, 49-12-51Page 411 201-210, Config-2 Aug 01/05
CES
(b)
TORQUE the castle nuts to between 0.55 and 0.75 m.daN (48.67 and
66.37 lbf.in) and safety them with the new cotter pin (18).
(c)
Connect the bonding strap at the bonding bracket (Ref. TASK 20-28-00-912-004).
(d)
Install the screws (22), the washers (21) and the nuts (19).
(e)
TORQUE the nuts (19) to between 0.22 and 0.26 m.daN (19.46 and
23.00 lbf.in).
(3)
Install the vibration isolator (12) on the APU mount-bracket (14).
(4)
Install the tie-rods (5), (10) and (11) at the vibration isolator (12).
(5)
Install the bolts (4) and (9), the washers (3) and (8) and the castle nuts (2) and (6).
(6)
TORQUE the castle nuts (6) to between 0.3 and 0.35 m.daN (26.54 and
30.97 lbf.in) and safety them with the new cotter pins (7).
(7)
TORQUE the castle nuts (2) to between 0.55 and 0.75 m.daN (48.67 and
66.37 lbf.in) and safety them with the new cotter pins (1).
(8)
Remove the PROTECTOR - THREADS, APU MOUNTING BOLTS and install the nut (13).
(9)
TORQUE the nut (13) to between 2.5 and 3.1 m.daN (18.43 and 22.86 lbf.ft)
R **ON A/C 107-107, 151-199, 204-210,
Subtask 49-12-51-420-056-A
B. Installation of the Vibration Isolator CAUTION : WHEN YOU REMOVE (INSTALL) THE APU, DISENGAGE (ENGAGE) ALL THE
_______ VIBRATION ISOLATORS AT THE SAME TIME FROM THE APU MOUNT BRACKETS. IF YOU DISENGAGE (ENGAGE) THEM ONE AFTER THE OTHER, THE LOADS WILL NOT BE EQUAL. THIS WILL CAUSE DAMAGE TO THE TIE RODS.
R EFF : 001-049, 101-105, 107-107, 151-199, 49-12-51Page 412 201-210, Config-2 Aug 01/05
CES (1) Protective Treatment
WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL
_______ MATERIALS ONLY WITH A GOOD SUPPLY OF AIR. OBEY THE MANUFACTURERS INSTRUCTIONS. PUT ON PROTECTIVE CLOTHING. DO NOT GET THEM IN YOUR MOUTH. DO NOT SMOKE. DO NOT BREATHE THE GAS. THESE MATERIALS ARE POISONOUS, FLAMMABLE AND SKIN IRRITANT. GET MEDICAL HELP IF YOUR SKIN OR EYES BECOME IRRITATED.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER2(85)