24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action 29-14-00-614-002 Pressurization of the Hydraulic Reservoirs through
 the Ground Connector 49-00-00-860-003 APU Start by External Power (GTCP 36-300) 49-00-00-860-004 APU Shutdown by External Power (GTCP 36-300) 52-41-00-010-001 Open the APU Doors for Access 52-41-00-410-001 Close the APU Doors after Access
 3. Job Set-up
__________
 Subtask 49-16-00-860-051
 A. Aircraft Maintenance Configuration
 (1)
 Energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-861-002).


 (2)
 On the panel 25VU, press the APU MASTER SW pushbutton switch then make sure that the APU air intake flap has moved to the fully open position.

 (3)
 Put a warning notice in the cockpit to tell persons not to start the APU.

 (4)
 Make sure that hydraulic systems are depressurized
 (Ref. TASK 29-00-00-864-001).

 

 

 Subtask 49-16-00-865-067
 B. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41
 Subtask 49-16-00-010-059
 C. Get Access
 (1)
 Put the access platform in position below the APU access doors 315AL and 316AR.

 (2)
 Open the APU access doors 315AL and 316AR (Ref. TASK 52-41-00-010-001).

 (3)
 Set the light SW 11LJ to the ON position.


 4. Procedure
_________
 Subtask 49-16-00-110-050
 A. Cleaning of the APU Air Intake System.
 (1) Make an inspection of the air intake duct and the APU Doors 315AL and 316AR for grease and oil contamination.
 -If you find any contamination do the following procedure:
 (a)
 Clean the APU air intake flap, the air intake duct internally and the APU Doors. Use pure CLEANING AGENTS (Material No. 11-011) as a spray with a pressure of 2-3 bar (29-43.5 psi) on:

 -
the inner walls of the installed air intake duct,

 -
the inner walls of the air intake housing including intake flap,

 -
the installed APU Doors.

 

 (b)
 Let the cleaning agent stay on the surfaces for 20 mins. to complete the cleaning process.


 (c) Rinse the cleaning agent from the surfaces with a hot-steam R water-cleaner at max. temperature and pressure of max. 5 bar R (72.5 psi)


 (d)
 Inspect the surfaces after the cleaning procedure.

 (e)
 Let the walls dry (15 min).

 (f)
 Start and operate the APU in the RTL or GEN LOAD mode for 15 mins. (Ref. TASK 49-00-00-860-003).

 (g)
 Shutdown the APU (Ref. TASK 49-00-00-860-004).


 (2) Do an inspection of the air intake duct for grease and oil contamination.
 -if the APU air intake duct is clean and dry the cleaning procedure is completed.
 5. Close-up
________ Subtask 49-16-00-410-060
 A. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Set the LIGHT control switch 11LJ to the off position.

 (3)
 Close the APU access doors 316AR, 315AL (Ref. TASK 52-41-00-410-001).


 (4)
 Remove the access platform(s). Subtask 49-16-00-865-068

 B.
 Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1KD, 2KD.


 Subtask 49-16-00-860-052
 C. Aircraft Maintenance Configuration
 (1)
 On the panel 25VU, push the APU MASTER SW pushbutton switch and make sure that the APU air intake flap moves to the fully closed position.

 (2)
 Pressurize the reservoirs of the hydraulic systems.
 (Ref. TASK 29-14-00-614-002).


 (3)
 De-energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-862-002).


 (4)
 Remove the warning notice(s).

 

 

 

 AIR INTAKE SYSTEM ((131-9(A))) - CLEANING/PAINTING
__________________________________________________
 TASK 49-16-00-100-003
 Cleaning of the APU Air Intake System (131-9(A))
 WARNING : DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER2(147)