R EFF : 001-049, 101-105, 107-107, 151-199, 49-16-41Page 406 201-210, Config-2 Aug 01/05
CES
(4)
Install the screws (4) and the washers (5).
(5)
Apply SEALANTS (Material No. 09-016) to the SEALANT AREA.
(6)
Put the shim (3) between the FR77 and the fixed diverter (12). NOTE : If necessary use one or two shims.
____
(7)
Install the screws (1) and the washers (2).
(8)
Make sure that the electrical bonding of the screws (1) is not higher than 2 milliohms (Ref. TASK 20-28-00-720-005).
(9)
Bond the head of the screws (1) with washers (2) (Ref. TASK 20-28-00-912-004).
(10) Apply a bead of MISCELLANEOUS (Material No. 19-016) between the fixed diverter and the aircraft structure and make it smooth.
5. Close-up
________ Subtask 49-16-41-410-053-A
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Close the access doors 314AR, 315AL and 316AR.
(3)
Remove access platforms below the access doors 314AR, 315AL and 316AR.
Subtask 49-16-41-865-064
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1KD, 2KD
Subtask 49-16-41-860-058-A
C. Aircraft Maintenance Configuration
(1)
Pressurize the reservoirs of the hydraulic systems.
(Ref. TASK 29-14-00-614-002).
(2)
De-energize the ground service network (Ref. TASK 24-41-00-862-002)
R EFF : 001-049, 101-105, 107-107, 151-199, 49-16-41Page 407 201-210, Config-2 Aug 01/05
CES
(3)
Remove the ground support and maintenance equipment, the special and
standard tools and all other items.
(4)
Remove the warning notice(s).