-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action 29-14-00-614-002 Pressurization of the Hydraulic Reservoirs through the Ground Connector 49-12-51-000-003 Removal of the FWD LH Tie-Rods and Vibration Isolator 4035KM (131-9(A)) 49-12-51-400-003 Installation of the FWD LH Tie -Rods and Vibration Isolator 4035KM (131-9(A)) 49-12-52-000-003 Removal of the FWD RH Tie-Rods and Vibration Isolator 4045KM (131-9(A)) 49-12-52-400-003 Installation of the FWD RH Tie-Rods and Vibration Isolator 4045KM (131-9(A)) 49-12-53-000-003 Removal of the AFT Tie-Rods and Vibration Isolator 4055KM (131-9(A)) 49-12-53-400-003 Installation of the AFT Tie-Rods and Vibration Isolator 4055KM (131-9(A)) 49-12-54-000-003 Removal of the APU Mount Brackets (4065KM, 4075KM, 4085KM) (131-9(A)) 49-12-54-400-003 Installation of the APU Mount Brackets (4065KM,
4075KM, 4085KM) (131-9(A))
52-41-00-010-001 Open the APU Doors for Access
52-41-00-410-001 Close the APU Doors after Access
**ON A/C 001-049, 101-105, 201-203,
49-12-00-991-007 Fig. 601
R **ON A/C 107-107, 151-199, 204-210,
49-12-00-991-007-A Fig. 601A
R EFF : 001-049, 101-105, 107-107, 151-199, 49-12-00Page 602 201-210, Config-2 Aug 01/05
CES
R **ON A/C 001-049, 101-105, 107-107, 151-199, 201-210,
3. Job Set-up
__________
Subtask 49-12-00-860-062
A. Aircraft Maintenance Configuration
(1)
Energize the ground service network
(Ref. TASK 24-42-00-861-001).
(2)
On the panel 25VU make sure that the APU MASTER SW p/bsw is OFF.
(3)
Put the warning notices on panel 25VU to tell persons not to start the APU.
(4)
Make sure that hydraulic systems are depressurized
(Ref. TASK 29-00-00-864-001).
Subtask 49-12-00-865-064
B. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41
Subtask 49-12-00-010-057
C. Get Access
(1)
Put the access platform in position below the APU access doors 315AL and 316AR.
(2)
Open the APU access doors 315AL, 316AR and safety them in the open position (Ref. TASK 52-41-00-010-001).
(3)
Set the LIGHT control SW 11LJ to the ON position.
R EFF : 001-049, 101-105, 107-107, 151-199, 49-12-00Page 603 201-210, Config-2 Aug 01/05
CES 4. Procedure
_________
**ON A/C 001-049, 101-105, 201-203,
(Ref. Fig. 601/TASK 49-12-00-991-007) R **ON A/C 107-107, 151-199, 204-210,
(Ref. Fig. 601A/TASK 49-12-00-991-007-A) R **ON A/C 001-049, 101-105, 107-107, 151-199, 201-210,
Subtask 49-12-00-110-055
A. Cleaning WARNING : DO NOT GET THE FLUID ON YOUR SKIN OR IN YOUR EYES. IF YOU DO:
_______
-FLUSH IT AWAY WITH CLEAN WATER
-GET MEDICAL AID.
(1) Clean the vibration isolators (4) and the tie-rods (3) with a lint free cloth and CLEANING AGENTS (Material No. 11-001).
NOTE : Apply the CLEANING AGENTS (Material No. 11-001) to the cloth
____ and not the cloth to the CLEANING AGENTS (Material No. 11-001). This will prevent the transfer of contamination.
(a)
Carefully clean a small area at a time and remove the CLEANING AGENTS (Material No. 11-001) before it becomes dry. Use a new lint free cloth frequently to make sure dirt is not put back on the surfaces.
(b)
Use a stiff bristle brush to clean any holes, corners and edges.
(2)
When the surfaces are clean, flush with clean water. WARNING : USE THE CORRECT PERSONAL PROTECTION.
_______ COMPRESSED AIR WILL CAUSE LOOSE PARTICLES THAT CAN GET IN YOUR EYES. THE AIRSTREAM CAN CAUSE CUTS, DO NOT POINT IT AT YOUR SKIN.
(3)
Dry the surfaces with dry, filtered compressed air at a maximum pressure of 1.4 bar (20 psi).
R EFF : 001-049, 101-105, 107-107, 151-199, 49-12-00Page 604 201-210, Config-2 Aug 01/05
CES Subtask 49-12-00-210-066
B. Visual Inspection of the APU Suspension
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 机载辅助动力 AIRBORNE AUXILIARY POWER2(73)