__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking plugs No specific warning notice No specific container 5.0 l (1.3208 USgal)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
Configuration before Maintenance Action 29-00-00-910-002 Safety Procedures of the Hydraulic System 29-14-00-614-001 Depressurization of the Hydraulic Reservoirs 29-12-63-991-001 Fig. 401
3. Job Set-up
__________ Subtask 29-12-63-860-050
A. Aircraft Maintenance Configuration
(1)
Obey the hydraulic safety procedures (Ref. TASK 29-00-00-910-002).
(2)
Remove the access panel 197BB.
(3)
Put the warning notice in position to tell persons not to pressurize the hydraulic systems:
-in the cockpit on the hydraulic section 40VU of the overhead panel.
(4)
Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration. (Ref. TASK 29-00-00-864-001).
(5)
Depressurize the reservoir of the Blue hydraulic system.
(Ref. TASK 29-14-00-614-001).
(6)
Put the container below the hydraulic connections of the ground connectors to collect the hydraulic fluid.
4. Procedure
_________
(Ref. Fig. 401/TASK 29-12-63-991-001) Subtask 29-12-63-020-050
A. Removal of the Self-Sealing Ground Connectors NOTE : The removal of the suction connector (2006GM) and the delivery
____ connector (2008GM) is the same. The procedure describes the removal only for one connector.
(1)
Disconnect the end-fitting (1) from the ground connector (5).
(2)
Put blanking plugs on the disconnected end-fitting (1) and the ground connector (5).
(3)
Remove the nuts (2) and the bolts (7).
(4)
Remove the mounting flange (4) with the ground connector (5) from the ground service panel (3).
Self-Sealing Ground Connectors of the Blue Hydraulic System
Figure 401/TASK 29-12-63-991-001
TASK 29-12-63-400-001
Installation of the Self-Sealing Ground Connectors of the Blue Hydraulic System
WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES.
_______
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific container
No specific hydraulic ground cart
No specific warning notice
R No specific Torque Wrench : range 0.00 to 1.20 m.daN R (0.00 to 9.00 lbf.ft) No specific Torque Wrench : range 2.00 to 20.00 m.daN
(15.00 to 150.00 lbf.ft)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 05-002 USA MIL-P-8116 PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00)
Material No. 07-003
ABRASION RESISTANT COATING (TEFLON POLYURET)
(Ref. 20-31-00)
Material No. 09-019 USA AMS 3267/3
LOW ADHESION CORROSION INHIBITING SEALANT
(Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
29-00-00-864-001 Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
29-00-00-910-002 Safety Procedures of the Hydraulic System
R 29-10-00-863-003 Pressurize the Blue Hydraulic System with a Ground
R Power Supply 29-10-00-864-003 Depressurize the Blue Hydraulic System 29-14-00-614-001 Depressurization of the Hydraulic Reservoirs 29-12-63-991-001 Fig. 401
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压3(93)