 Fluid Sampling Valve
 Figure 401/TASK 29-12-34-991-001

R 1EFF : 001-049, 051-058, 101-101, 1 29-12-34Page 404 1 1 May 01/05 1 1 1CES 1


 Fluid Sampling Valve
 Figure 401A/TASK 29-12-34-991-001-A

R 1EFF : 059-099, 102-149, 151-199, 201-299, 1 29-12-34Page 405 1301-399, 401-499, 1Aug 01/05 1 1 1CES 1 TASK 29-12-34-400-001


 Installation of the Fluid Sampling Valve of the Blue Hydraulic System (2187GM)
 WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
 GEAR.

 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
 No specific container
 No specific warning notices
 No specific Torque Wrench : range 0.20 to 3.60 m.daN

 (2.00 to 26.00 lbf.ft)
 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
No specific  lockwire, corrosion-resistant steel, 0.8 mm (0.032 in.) dia
R Material No. 02-003  F NSA 307110 TYPE 4 HYDRAULIC FLUID (PHOSPHATE ESTER BASE) (Ref. 20-31-00)
 C. Expendable Parts
 -------------------------------------------------------------------------------FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
0-ring  29-12-14 02B-320 D. Referenced Information


 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
12-12-29-611-001 Fill the Hydraulic Fluid Reservoir with a Hand Pump 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
 Configuration before Maintenance Action 29-00-00-910-002 Safety Procedures of the Hydraulic System 29-10-00-863-003 Pressurize the Blue Hydraulic System with a Ground
 Power Supply
 29-10-00-864-003 Depressurize the Blue Hydraulic System
 29-14-00-614-001 Depressurization of the Hydraulic Reservoirs

 **ON A/C 001-049, 051-058, 101-101,
 29-12-34-991-001 Fig. 401
R **ON A/C 059-099, 102-149, 151-199, 201-299, 301-399, 401-499,
 29-12-34-991-001-A Fig. 401A
 **ON A/C ALL
 3. Job Set-up
__________
 Subtask 29-12-34-860-051
 A. Aircraft Maintenance Configuration
 WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES.
_______
 (1)
 Obey the hydraulic safety procedures (Ref. TASK 29-00-00-910-002).

 (2)
 Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration. (Ref. TASK 29-00-00-864-001).

 (3)
 Make sure that the reservoir of the Blue hydraulic system is depressurized. (Ref. TASK 29-14-00-614-001).

 (4)
 Make sure that the access panel 195BB and the access door 197EB are open.

 (5)
 Make sure that the container is in position below the HP manifold.

 (6)
 Make sure that the warning notices are in position to tell persons not to pressurize the Blue hydraulic system:

 


 -in the cockpit on the hydraulic section 40VU of the overhead panel, - on the ground service panel of the Blue hydraulic system.
 Subtask 29-12-34-865-051
 B. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
 -------------------------------------------------------------------------------
49VU HYD/HYD PWR/B WARN/& CTL 2702GJ C12 121VU HYDRAULIC/LOW/LVL/IND 1832GQ N32 121VU HYDRAULIC/HYD/QTY/IND 1831GQ P35 123VU B HYD/ELEC PUMP 2701GJ AB09
 4. Procedure
_________
 **ON A/C 001-049, 051-058, 101-101,

 (Ref. Fig. 401/TASK 29-12-34-991-001) R **ON A/C 059-099, 102-149, 151-199, 201-299, 301-399, 401-499,
 (Ref. Fig. 401A/TASK 29-12-34-991-001-A)
 **ON A/C ALL

 Subtask 29-12-34-420-050
 A. Installation of the Fluid Sampling Valve
 (1)
 Clean the component interface and/or the adjacent area.

 (2)
 Do an inspection of the component interface and/or the adjacent area.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压3(47)