R  (f) Tighten the bolts (12) (Ref. TASK 20-28-00-912-002). 
R  (g) Remove the blanking caps from the electrical connectors. 
R  (h) Identify and connect the electrical connectors of the cable (8) 
R  with the screws (3), (4) and (5).

 

R  (i) TORQUE the screws (3), (4) and (5) as follows: 
R  - the screw (3) to between 0.102 and 0.124 m.daN (9.02 and 10.97 
R  lbf.in) 
R  - the screw (4) to between 0.203 and 0.226 m.daN (17.96 and 19.99 
R  lbf.in) 
R  - the screw (5) to between 0.316 and 0.362 m.daN (27.96 and 32.03 
R  lbf.in). 
R  (j) Put the cable (8) in position under the clamp block (6) and 
R  TORQUE the clamp screw (7) to between 0.023 and 0.045 m.daN (2.03 
R  and 3.98 lbf.in). 
R  (k) Install the cable ties (1), as necessary, to attach the cable (8) 
R  to the probe (11). 
R  (2) Installation of the probe 54QT1 (54QT2): 
R  CAUTION : REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU_______ 
R  CONNECT THE ELECTRICAL WIRES. 
R  INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO 
R  EQUIPMENT. 
R  FOR 54QT1, 54QT2 
R  (Ref. Fig. 406/TASK 28-42-15-991-005) 
R  (a) Install the bracket (18) on the probe (16). 
R  (b) Put the probe (16) in the correct position and loosely install 
R  the bolts (17) and the nuts (19). 
R  (c) Loosely install the bolts (14) and the washers (13). 
R  (d) Measure the clearance between the structure and the top and 
R  bottom of the probe (16). Make sure that the clearance is a 
R  minimum of 7.00 mm (0.2755 in.). 
R  NOTE : When a probe is installed, a minimum clearance of 7.0 mm____ 
R  (0.2755 in.) is recommended. (A clearance of less than 7.0 
R  mm (0.2755 in.) but more than 5.0 mm (0.1968 in.) is 
R  acceptable, if local installation does not allow the 
R  recommended clearance) 
R  (e) To prevent possible static discharge, maks sure that the fuel 
R  probe is not less than 5.0 mm (0.1968 in.) from: 
R  - the nearest structure 
R  - rib and tank wall 
R  - pipework

 

R  - brackets and p-clips 
R  - fasteners and other metal parts. 
R  (f) TORQUE the bolts (14) to between 0.45 and 0.56 m.daN (39.82 and 
R  49.55 lbf.in) (Ref. TASK 20-28-00-912-002). 
R  (g) Tighten the bolts (17) and the nuts (19) (Ref. TASK 20-28-00-912-
R  002). 
R  (h) Remove the blanking caps from the electrical connectors. 
R  (i) Identify and connect the electrical connectors of the cable (8) 
R  to the temperature sensor (11) with the screws (12) and (15). 
R  (j) TORQUE the screws (12) to between 0.102 and 0.124 m.daN (9.02 and 
R  10.97 lbf.in). 
R  (k) TORQUE the screws (15) to between 0.203 and 0.226 m.daN (17.96 
R  and 19.99 lbf.in). 
R  (l) Put the cable (8) in position under the clamp blocks (9). 
R  (m) TORQUE the clamp screws (10) to between 0.023 and 0.045 m.daN 
R  (2.03 and 3.98 lbf.in). 
R  (n) Identify and connect the electrical connectors of the cable (8) 
R  with the screws (3), (4) and (5). 
R  (o) TORQUE the screws (3), (4) and (5) as follows: 
R  - the screw (3) to between 0.102 and 0.124 m.daN (9.02 and 10.97 
R  lbf.in) 
R  - the screw (4) to between 0.203 and 0.226 m.daN (17.96 and 19.99 
R  lbf.in) 
R  - the screw (5) to between 0.316 and 0.362 m.daN (27.96 and 32.03 
R  lbf.in). 
R  (p) Put the cable (8) in position under the clamp block (6) and 
R  TORQUE the clamp screw (7) to between 0.023 and 0.045 m.daN (2.03 
R  and 3.98 lbf.in). 
R  (q) Install the cable ties (1), as necessary, to attach the cable (8) 
R  to the probe (16).

 

R  (3) Installation of the probe 23QT1 (23QT2), 56QT1 (56QT2), 25QT1 
R  (25QT2)... 
R  CAUTION : REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU_______ 
R  CONNECT THE ELECTRICAL WIRES. 
R  INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO 
R  EQUIPMENT. 
R  FOR 23QT1, 23QT2, 56QT1, 56QT2, 25QT1, 25QT2, 26QT1, 26QT2, 27QT1, 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油5(67)