1EFF : 301-399, 1 28-42-00Page 579 1 1 Aug 01/05R 1 1 1CES 1
INDEX DATA DESCRIPTION FAILURE MESSAGE -------------------------------------------------------------------------------
214 H * RTU2 or diode voltage out of range R QTY PROBE 54QT2
215 H * RTU3 or diode voltage out of range R QTY PROBE 23QT2
216 H * RTU4 or diode voltage out of range R QTY PROBE 56QT2
217 H * RTU5 or diode voltage out of range R QTY PROBE 25QT2
218 H * RTU6 or diode voltage out of range R QTY PROBE 26QT2
219 H * RTU7 or diode voltage out of range R QTY PROBE 27QT2
21A H * RTU8 or diode voltage out of range R QTY PROBE 28QT2
21B H * RTU9 or diode voltage out of range R QTY PROBE 29QT2
21C H * RTU10 or diode voltage out of range R QTY PROBE 30QT2
21D H * RTU11 or diode voltage out of range R QTY PROBE 59QT2
21E H * RTU12 or diode voltage out of range R QTY PROBE 60QT2
21F H * RTU13 or diode voltage out of range R QTY PROBE 61QT2
220 H * RTU14 or diode voltage out of range R QTY PROBE 34QT2
226 H * Wiring fault RUCOMP R ULTRACOMP 52QT/WRG
227 H * Wiring fault RTU1 R QTY PROBE 21QT2/WRG
228 H * Wiring fault RTU2 R QTY PROBE 54QT2/WRG
229 H * Wiring fault RTU3 R QTY PROBE 23QT2/WRG
22A H * Wiring fault RTU4 R QTY PROBE 56QT2/WRG
22B H * Wiring fault RTU5 R QTY PROBE 25QT2/WRG
22C H * Wiring fault RTU6 R QTY PROBE 26QT2/WRG
22D H * Wiring fault RTU7 R QTY PROBE 27QT2/WRG
22E H * Wiring fault RTU8 R QTY PROBE 28QT2/WRG
22F H * Wiring fault RTU9 R QTY PROBE 29QT2/WRG
230 H * Wiring fault RTU10 R QTY PROBE 30QT2/WRG
231 H * Wiring fault RTU11 R QTY PROBE 59QT2/WRG
232 H * Wiring fault RTU12 R QTY PROBE 60QT2/WRG
233 H * Wiring fault RTU13 R QTY PROBE 61QT2/WRG
234 H * Wiring fault RTU14 R QTY PROBE 34QT2/WRG
244 H * Capacitance sensor A1TU1 invalid FQIC 3QT
245 H * Capacitance sensor A1TU2 invalid FQIC 3QT
246 H * Capacitance sensor A2TU1 invalid
247 H * Capacitance sensor A2TU2 invalid
24E H * A1TU1 or diode volt drop out of range A1 QTY PROBE 65QT1
24F H * A1TU2 or diode volt drop out of range A1 QTY PROBE 66QT1
250 H * A2TU1 or diode volt drop out of range
251 H * A2TU2 or diode volt drop out of range
258 H * wiring fault A1TU1 A1 QTY PROBE 65QT1/WRG
259 H * wiring fault A1TU2 A1 QTY PROBE 66QT1/WRG
25A H * wiring fault A2TU1
25B H * wiring fault A2TU2
26C H * Probes LTU4 & LTU5 invalid (degraded) L DOUBLE PROBE FAILURE
26D H * Probes LTU5 & LTU6 invalid (degraded) L DOUBLE PROBE FAILURE
26E H * Probes LTU6 & LTU7 invalid (degraded) L DOUBLE PROBE FAILURE
26F H * Probes LTU7 & LTU8 invalid (failed) L DOUBLE PROBE FAILURE
270 H * Probes LTU8 & LTU9 invalid (degraded) L DOUBLE PROBE FAILURE
1EFF : 301-399, 1 28-42-00Page 580 1 1 Aug 01/05R 1 1 1CES 1
INDEX DATA DESCRIPTION FAILURE MESSAGE -------------------------------------------------------------------------------
271 H * Probes LTU9 & LTU10 invalid (failed) L DOUBLE PROBE FAILURE
272 H * Probes LTU10 & LTU11 invalid (failed) L DOUBLE PROBE FAILURE
273 H * Probes LTU11 & LTU12 invalid (failed) L DOUBLE PROBE FAILURE
274 H * Probes LTU12 & LTU13 invalid (degraded)L DOUBLE PROBE FAILURE
275 H * Probes LTU13 & LTU14 invalid (degraded)L DOUBLE PROBE FAILURE
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油5(41)