1EFF : 301-399, 1 28-42-00Page 578 1 1 Aug 01/05R 1 1 1CES 1
INDEX DATA DESCRIPTION FAILURE MESSAGE -------------------------------------------------------------------------------
1DB H * LTU4 or diode voltage out of range L QTY PROBE 56QT1
1DC H * LTU5 or diode voltage out of range L QTY PROBE 25QT1
1DD H * LTU6 or diode voltage out of range L QTY PROBE 26QT1
1DE H * LTU7 or diode voltage out of range L QTY PROBE 27QT1
1DF H * LTU8 or diode voltage out of range L QTY PROBE 28QT1
1E0 H * LTU9 or diode voltage out of range L QTY PROBE 29QT1
1E1 H * LTU10 or diode voltage out of range L QTY PROBE 30QT1
1E2 H * LTU11 or diode voltage out of range L QTY PROBE 59QT1
1E3 H * LTU12 or diode voltage out of range L QTY PROBE 60QT1
1E4 H * LTU13 or diode voltage out of range L QTY PROBE 61QT1
1E5 H * LTU14 or diode voltage out of range L QTY PROBE 34QT1
1EA H * Wiring fault LDCOMPA L DUALCOMP 53QT/WRG
1EB H * Wiring fault LDCOMPB L DUALCOMP 53QT/WRG
1EC H * Wiring fault LTU1 L QTY PROBE 21QT1/WRG
1ED H * Wiring fault LTU2 L QTY PROBE 54QT1/WRG
1EE H * Wiring fault LTU3 L QTY PROBE 23QT1/WRG
1EF H * Wiring fault LTU4 L QTY PROBE 56QT1/WRG
1F0 H * Wiring fault LTU5 L QTY PROBE 25QT1/WRG
1F1 H * Wiring fault LTU6 L QTY PROBE 26QT1/WRG
1F2 H * Wiring fault LTU7 L QTY PROBE 27QT1/WRG
1F3 H * Wiring fault LTU8 L QTY PROBE 28QT1/WRG
1F4 H * Wiring fault LTU9 L QTY PROBE 29QT1/WRG
1F5 H * Wiring fault LTU10 L QTY PROBE 30QT1/WRG
1F6 H * Wiring fault LTU11 L QTY PROBE 59QT1/WRG
1F7 H * Wiring fault LTU12 L QTY PROBE 60QT1/WRG
1F8 H * Wiring fault LTU13 L QTY PROBE 61QT1/WRG
1F9 H * Wiring fault LTU14 L QTY PROBE 34QT1/WRG
1FE H * Capacitance Sensor RUCOMP invalid FQIC 3QT
1FF H * Capacitance Sensor RTU1 invalid FQIC 3QT
200 H * Capacitance Sensor RTU2 invalid FQIC 3QT
201 H * Capacitance Sensor RTU3 invalid FQIC 3QT
202 H * Capacitance Sensor RTU4 invalid FQIC 3QT
203 H * Capacitance Sensor RTU5 invalid FQIC 3QT
204 H * Capacitance Sensor RTU6 invalid FQIC 3QT
205 H * Capacitance Sensor RTU7 invalid FQIC 3QT
206 H * Capacitance Sensor RTU8 invalid FQIC 3QT