BIT DESCRIPTION VALUE
-------------------------------------------------------------------------------R 01 Tank Unit calibration low RTU 4 True = in range R 00 Tank Unit calibration high RTU 4 True = in range
1EFF : 301-399, 1 28-42-00Page A503 1 1 Feb 01/05 1 1 1CES 1 Subtask 28-42-00-740-098
L. EVENT 7 (H) : CT/COLLECTOR/ACT SC1
CT/COLLECTOR - Snapshot Word 1
BIT TRIG DESCRIPTION VALUE -------------------------------------------------------------------------------15 C Status of capacitance sensor RTU1 True = valid 14 B Status of capacitance sensor CTU5 True = valid 13 A Status of capacitance sensor CTU1 True = valid 12 9 Status of capacitance sensor CUCOMP True = valid -------------------------------------------------------------------------------11 8 Combined status of probes LTU7 and LTU8 True = 1 probe valid 10 7 Combined status of probes LTU6 and LTU7 True = 1 probe valid 09 6 Combined status of probes LTU5 and LTU6 True = 1 probe valid 08 5 Combined status of probes LTU4 and LTU5 True = 1 probe valid -------------------------------------------------------------------------------07 4 Combined status of probes CTU4 and CTU5 True = 1 probe valid 06 3 Combined status of probes CTU3 and CTU5 True = 1 probe valid 05 2 Combined status of probes CTU1 and CTU3 True = 1 probe valid 04 1 Combined status of probes CTU1 and CTU2 True = 1 probe valid -------------------------------------------------------------------------------03 | Trigger number 02 | " 01 | " 00 | "
NOTE : The TRIG references D, E, F and 0 are given in the
____ CT/COLLECTOR/ACT SC1 - Snapshot Word 2, bits 00 thru 03, (see the next page).
The column identified as TRIG, and the related data,
is only given when applicable
(for snapshot words 1 and 2).
1EFF : 301-399, 1 28-42-00Page A504 1 1 May 01/05R 1 1 1CES 1
R CT/COLLECTOR - Snapshot Word 2
R
R BIT TRIG DESCRIPTION VALUE
R -------------------------------------------------------------------------------
R 15 LO-Z SC1 in range DRIVER 3 True = in range
R 14 LO-Z SC1 in range DRIVER 2 True = in range
R 13 LO-Z SC1 in range DRIVER 1 True = in range
R 12 Accuracy state of total fuel qty True = failed
R -------------------------------------------------------------------------------
R 11 Accuracy state of total fuel qty True = degraded
R 10 Accuracy state of total fuel qty True = normal
R 09 Status of diode voltage for LTU2 True = valid
R 08 Status of diode voltage for RTU1 True = valid
R -------------------------------------------------------------------------------
R 07 Status of diode voltage for CTU5 True = valid
R 06 Status of diode voltage for CTU1 True = valid
R 05 Status of diode voltage for CUCOMP True = valid
R 04 Status of capacitance sensor LTU2 True = in range
R -------------------------------------------------------------------------------
R 03 0 Status of capacitance sensor RTU1 True = in range
R 02 F Status of capacitance sensor CTU5 True = in range
R 01 E Status of capacitance sensor CTU1 True = in range
R 00 D Status of capacitance sensor LTU2 True = valid
R CT/COLLECTOR - Snapshot Word 3
R
R BIT DESCRIPTION VALUE
R -------------------------------------------------------------------------------
R 15 Status of opp CPU power supply True = healthy
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油5(50)