R  15 
R  14 
R  13 Indicates failure status of SC2 board False = SC2 not failed 
R  12 Indicates if channel is master or slave True = master 
R  -------------------------------------------------------------------------------
R  11 Tank Unit calibration low RTU14 True = in range 
R  10 Tank Unit calibration high RTU14 True = in range 
R  09 Tank Unit calibration low RTU 12 True = in range 
R  08 Tank Unit calibration high RTU12 True = in range 
R  -------------------------------------------------------------------------------
R  07 Tank Unit calibration low RTU 10 True = in range 
R  06 Tank Unit calibration high RTU 10 True = in range 
R  05 Tank Unit calibration low RTU 8 True = in range 
R  04 Tank Unit calibration high RTU 8 True = in range 
R  -------------------------------------------------------------------------------
R  03 Tank Unit calibration low RTU 6 True = in range 
R  02 Tank Unit calibration high RTU 6 True = in range

 

 BIT DESCRIPTION VALUE
 -------------------------------------------------------------------------------R 01 Tank Unit calibration low RTU 4 True = in range R 00 Tank Unit calibration high RTU 4 True = in range
 1EFF : 301-399, 1 28-42-00Page A503 1 1 Feb 01/05 1 1 1CES 1 Subtask 28-42-00-740-098


 L. EVENT 7 (H) : CT/COLLECTOR/ACT SC1
 CT/COLLECTOR - Snapshot Word 1
 BIT TRIG DESCRIPTION VALUE -------------------------------------------------------------------------------15 C Status of capacitance sensor RTU1 True = valid 14 B Status of capacitance sensor CTU5 True = valid 13 A Status of capacitance sensor CTU1 True = valid 12 9 Status of capacitance sensor CUCOMP True = valid -------------------------------------------------------------------------------11 8 Combined status of probes LTU7 and LTU8 True = 1 probe valid 10 7 Combined status of probes LTU6 and LTU7 True = 1 probe valid 09 6 Combined status of probes LTU5 and LTU6 True = 1 probe valid 08 5 Combined status of probes LTU4 and LTU5 True = 1 probe valid -------------------------------------------------------------------------------07 4 Combined status of probes CTU4 and CTU5 True = 1 probe valid 06 3 Combined status of probes CTU3 and CTU5 True = 1 probe valid 05 2 Combined status of probes CTU1 and CTU3 True = 1 probe valid 04 1 Combined status of probes CTU1 and CTU2 True = 1 probe valid -------------------------------------------------------------------------------03 | Trigger number 02 | " 01 | " 00 | "
 NOTE : The TRIG references D, E, F and 0 are given in the
____ CT/COLLECTOR/ACT SC1 - Snapshot Word 2, bits 00 thru 03, (see the next page).
 The column identified as TRIG, and the related data,
 is only given when applicable
 (for snapshot words 1 and 2).

 1EFF : 301-399, 1 28-42-00Page A504 1 1 May 01/05R 1 1 1CES 1


R  CT/COLLECTOR - Snapshot Word 2 

R  BIT TRIG DESCRIPTION VALUE 
R  -------------------------------------------------------------------------------
R  15 LO-Z SC1 in range DRIVER 3 True = in range 
R  14 LO-Z SC1 in range DRIVER 2 True = in range 
R  13 LO-Z SC1 in range DRIVER 1 True = in range 
R  12 Accuracy state of total fuel qty True = failed 
R  -------------------------------------------------------------------------------
R  11 Accuracy state of total fuel qty True = degraded 
R  10 Accuracy state of total fuel qty True = normal 
R  09 Status of diode voltage for LTU2 True = valid 
R  08 Status of diode voltage for RTU1 True = valid 
R  -------------------------------------------------------------------------------
R  07 Status of diode voltage for CTU5 True = valid 
R  06 Status of diode voltage for CTU1 True = valid 
R  05 Status of diode voltage for CUCOMP True = valid 
R  04 Status of capacitance sensor LTU2 True = in range 
R  -------------------------------------------------------------------------------
R  03 0 Status of capacitance sensor RTU1 True = in range 
R  02 F Status of capacitance sensor CTU5 True = in range 
R  01 E Status of capacitance sensor CTU1 True = in range 
R  00 D Status of capacitance sensor LTU2 True = valid 
R  CT/COLLECTOR - Snapshot Word 3 

R  BIT DESCRIPTION VALUE 
R  -------------------------------------------------------------------------------
R  15 Status of opp CPU power supply True = healthy 
 