TEMPERATURE/DENSITO - Snapshot Word 4
BIT DESCRIPTION VALUE -------------------------------------------------------------------------------15 Power supply status on SC2 board True = healthy 14 Power supply status on SC1 board True = healthy 13 Indicates if VOS from chn 2 is healthy True = healthy 12 Indicates if VOS from chn 1 is healthy True = healthy -------------------------------------------------------------------------------11 Temperature computation status on chn 2 True = healthy 10 Temperature computation status on chn 1 True = healthy 09 Status of temp sensors in RII tank True = no both invalid 08 Status of temp sensors in LII tank True = no both invalid -------------------------------------------------------------------------------07 Indicates failure status of SC2 board False = SC2 not failed 06 Indicates failure status of SC1 board False = SC1 not failed 05 Immersion status of RIX Ultracomp True = Wet 04 Immersion status of CT Ultracomp True = Wet -------------------------------------------------------------------------------03 Status of filtered VOS from RIVOS True = valid 02 Status of filtered VOS from CVOS True = valid 01 Status of temperature sensor RTEMPVOS False = not bad 00 Status of temperature sensor CTEMPVOS False = not bad
TEMPERATURE/DENSITO - Snapshot Word 5
BIT DESCRIPTION VALUE -------------------------------------------------------------------------------15 14 13 12 Snapshot spare Always false -------------------------------------------------------------------------------11 Wraparound from opposite CPU True = opp CPU healthy 10 Indicates opp 28V power supply True = 28V present 09 Right tank temperature status, chn own True = normal op 08 Left tank temperature status, chn own True = normal op -------------------------------------------------------------------------------07 Temp cross comp condi with bus B on RII True = conditions OK 06 Temp cross comp condi with bus B on LII True = conditions OK 05 Temp cross comp condi with bus A on RII True = conditions OK 04 Temp cross comp condi with bus A on LII True = conditions OK -------------------------------------------------------------------------------03 Chan 2 temp blanked intermediate value False = not blanked 02 Chan 1 temp blanked intermediate value False = not blanked 01 Channel 2: all fuel qty display blanked False = not blanked 00 Channel 1: all fuel qty display blanked False = not blanked
1EFF : 301-399, 1 28-42-00Page 594 1 1 Aug 01/05R 1 1 1CES 1
Subtask 28-42-00-740-096
J. EVENT 5 (H) : WINGS SC1 (Signal Conditioner)
WINGS SC1 - Snapshot Word 1
BIT TRIG DESCRIPTION VALUE -------------------------------------------------------------------------------15 C Status of capacitance sensor RTU11 True = valid 14 B Status of capacitance sensor RTU9 True = valid 13 A Status of capacitance sensor RTU7 True = valid 12 9 Status of capacitance sensor RTU5 True = valid -------------------------------------------------------------------------------11 8 Status of capacitance sensor RTU3 True = valid 10 7 Status of capacitance sensor LTU14 True = valid 09 6 Status of capacitance sensor LTU12 True = valid 08 5 Status of capacitance sensor LTU10 True = valid -------------------------------------------------------------------------------07 4 Status of capacitance sensor LTU8 True = valid 06 3 Status of capacitance sensor LTU6 True = valid 05 2 Status of capacitance sensor LTU4 True = valid 04 Status of capacitance sensor LDCOMPB True = valid -------------------------------------------------------------------------------03 | Trigger number 02 | " 01 | " 00 | "
NOTE : The TRIG references D, E, F and 0 are given in the
____
WINGS SC1 - Snapshot Word 2, bits 00 thru 03,
(see the next page).
The column identified as TRIG, and the related data,
is only given when applicable
(for snapshot words 1 and 2).
1EFF : 301-399, 1 28-42-00Page 595 1 1 Aug 01/05R 1 1 1CES 1
WINGS SC1 - Snapshot Word 2
BIT TRIG DESCRIPTION VALUE -------------------------------------------------------------------------------15 Status of diode voltage for LTU4 True = valid 14 Status of diode voltage for LDCOMPB True = valid 13 Status of capacitance sensor RTU13 True = in range 12 Status of capacitance sensor RTU11 True = in range -------------------------------------------------------------------------------11 Status of capacitance sensor RTU9 True = in range 10 Status of capacitance sensor RTU7 True = in range 09 Status of capacitance sensor RTU5 True = in range 08 Status of capacitance sensor RTU3 True = in range -------------------------------------------------------------------------------07 Status of capacitance sensor LTU14 True = in range 06 Status of capacitance sensor LTU12 True = in range 05 Status of capacitance sensor LTU10 True = in range 04 Status of capacitance sensor LTU8 True = in range -------------------------------------------------------------------------------03 0 Status of capacitance sensor LTU6 True = in range 02 F Status of capacitance sensor LTU4 True = in range 01 E Status of capacitance sensor LDCOMPB True = in range 00 D Status of capacitance sensor RTU13 True = valid