| | Displayed Value | | Parameter |--------------------------------------------------------------| | | Actual Value | Value with "*" | "XX..X" | |-------------|--------------------|------------------|----------------------| | | data is available | | | | | and good). | | | |-------------|--------------------|------------------|----------------------| | Probe | Probe available and| Probe available | Probe not available. | | Capacitance | capacitance range | and capacitance | (Due to failure of an| | | check not failed. | range check | FQIC circuit). | | | | failed. | |
----------------------------------------------------------------------------
Subtask 28-42-00-740-058
R C. Discrete Input Parameters (Ref. Fig. 503/TASK 28-42-00-991-003)
R R R R (1) Refer to the TSM only after the Input Parameter state has been found. The grid reference gives the Discrete Input state. For example: - the letter A = the first column and the number 1 = the first row.
R R The grid reference for the first input state is A1. See table 1 for row 1 states
R - the letter R = the last column and the number 8 = the last row. The
R R grid reference for the last input state is R8. See table 8 for row 8 states.
R R Input Parameter values that are defective or not available may be replaced by crosses (xx) or an asterisk.
Table 1 - First Row
--------------------------------------------------------------------------
|GRID REF| DISCRETE | STATE 1 | STATE 0 | |--------------------------------------------------------------------------| | A1 | Not used | | | | B1 | EEPROM ready discrete line | Ready | Fault | | C1 | Not used | | | | D1 | Own fail return | Fail | No fault | | E1 | Not used | | | | F1 | Not used | | | | G1 | Not used | | | | H1 | Other fail | Fail | No fault | | J1 | LOGIC 1 (IDG) FLSCU2 | Open | Not Open | | K1 | BITE 4 Lane 2 return | Fault | No fault | | L1 | LS7 FLSCU2 6QJ dry | Ready | Fault | | M1 | Left inner low level sensor LS10 - Wet | Wet | Not wet |
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-42-00Page 526 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
Table 1 - First Row
--------------------------------------------------------------------------|GRID REF| DISCRETE | STATE 1 | STATE 0 | |--------------------------------------------------------------------------| | N1 | Left inner underfull sensor LS15 - Wet | Wet | Not wet | | P1 | Not used | | | | Q1 | Delatch lane B return | Ready | Fault | | R1 | Battery power | Ready | Fault | --------------------------------------------------------------------------
Table 2 - Second Row
--------------------------------------------------------------------------|GRID REF| DISCRETE | STATE 1 | STATE 0 | |--------------------------------------------------------------------------| | A2 | ARINC Output 1 | Ready | Fault | | B2 | ARINC Output 2 | Ready | Fault | | C2 | ARINC Output 3 | Ready | Fault | | D2 | Other lane 5V present | Ready | Fault | | E2 | ARINC Input 1 | Ready | Fault | | F2 | ARINC Input 2 | Ready | Fault | | G2 | ARINC Input 3 | Ready | Fault | | H2 | Not used | | | | J2 | Right inner temperature sensor - High | High | Low | | K2 | BITE 3 Lane 2 return | Fault | No fault | | L2 | Right inner full sensor LS12 - Wet | Wet | Not wet | | M2 | Left inner underfull sensor LS14 - Wet | Wet | Not wet | | N2 | FLSCU1 Sensor failure | Fail | No fault | | P2 | Not used | | | | Q2 | Delatch lane B return | Delatch | Fault | | R2 | Cockpit preselector TX fault/not powered | Fault |Operation | --------------------------------------------------------------------------
Table 3 - Third Row
--------------------------------------------------------------------------|GRID REF| DISCRETE | STATE 1 | STATE 0 | |--------------------------------------------------------------------------| | A3 | ARINC Multiplexor 1 |Operation| Fault | | B3 | ARINC Multiplexer 2 |Operation| Fault | | C3 | ARINC Multiplexer 3 |Operation| Fault | | D3 | Not used | | | | E3 | Not used | | | | F3 | 15 V Fault | Fault | No fault | | G3 | Not used | | | | H3 | Not used | | | | J3 | Right inner high level sensor LS3 - Dry | Dry | Not dry | | K3 | BITE 2 Lane 2 return | Fault | No fault | | L3 | Right inner underfull sensor LS15 - Wet | Wet | Not wet |