Input Parameters - Page 2 (FQIS Probe Capacitances)
Figure 502/TASK 28-42-00-991-002- 22 (SHEET 2)
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-42-00Page 519 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
R Input Parameters - Page 2 (FQIS Probe Capacitances) Figure 502A/TASK 28-42-00-991-002-A12 (SHEET 1)
R 1EFF : 301-399, 1 28-42-00Page 520 1 1 Nov 01/04 1 1 1CES 1
R Input Parameters - Page 2 (FQIS Probe Capacitances) Figure 502A/TASK 28-42-00-991-002-A22 (SHEET 2)
R 1EFF : 301-399, 1 28-42-00Page 521 1 1 Nov 01/04 1 1 1CES 1
Input Parameters - Page 3 (FQIS Discrete Inputs)
Figure 503/TASK 28-42-00-991-003
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-42-00Page 522 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
5. On the MCDU control panel push - the MCDU shows the page FQIS DISCRETE the NEXT PAGE key. INPUTS.
**ON A/C 301-399,
Subtask 28-42-00-740-057-A
A. Get Access to the FQIC Input Parameters Pages:
NOTE : The FQIS input parameter pages are automatically updated every 5.5
____
seconds.
(1) When the SYSTEM REPORT/TEST Menu page comes into view, do this procedure: (Ref. Fig. 501A/TASK 28-42-00-991-001-A, 502A/TASK 28-42-00-991-002-A, 503A/TASK 28-42-00-991-003-A)
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1.
Push the line key adjacent to the FUEL indication.
2.
On the MCDU control panel push the NEXT PAGE key.
3.
Push the line key adjacent to the INPUT PARAMETER VALUES indication.
4.
On the MCDU control panel push the NEXT PAGE key.
5.
On the MCDU control panel push the NEXT PAGE key.
-
the FUEL Main Menu first page comesinto view.
-
the FUEL Main Menu second page comesinto view.
-
the MCDU shows the page FQIS INPUTPARAMETERS.
-
the MCDU shows the page FQIS PROBECAPACITANCES.
-
the MCDU shows the page FQIS DISCRETEINPUTS.
1EFF : ALL 1 28-42-00Page 523 1 1 May 01/05R 1 1 1CES 1
R Input Parameters - Page 3 (FQIS Discrete Inputs) Figure 503A/TASK 28-42-00-991-003-A
R 1EFF : 301-399, 1 28-42-00Page 524 1 1 Nov 01/04 1 1 1CES 1
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
Subtask 28-42-00-740-071
R B. Table A
R (1) Any Input Parameter values that are defective or not available may be
R replaced by crosses (xx) or an asterisk. The TSM should be used to
R find the cause of the malfunction.
R (Ref. Fig. 501/TASK 28-42-00-991-001, 502/TASK 28-42-00-991-002)
----------------------------------------------------------------------------
| | Displayed Value |
| Parameter |--------------------------------------------------------------|
| | Actual Value | Value with "*" | "XX..X" |
|-------------|--------------------|------------------|----------------------|
| Cadensicon | Cadensicon covered | Cadensicon not | Kd not available |
| permittivity| and Kd range check | covered or Kd | (due to failure of |
| (Kd) | not failed. | range check | an FQIC circuit or |
| | | failed. | the K-cell |
| | | | capacitance). |
|-------------|--------------------|------------------|----------------------|
| Cadensicon | Cadensicon covered | Cadensicon not | Cadensicon density |
| density (D) | and density range | covered or | not available |
| | check not failed. | density range | (due to failure of |
| | | check failed. | an FQIC circuit). |
|-------------|--------------------|------------------|----------------------|
| CIC | CIC covered and | CIC not covered | Kt not available |
| permittivity| Kt range check | or Kt range check| (due to failure of an|
| (Kt) | not failed. | failed. | FQIC circuit or the |
| | | | CIC capacitance). |
|-------------|--------------------|------------------|----------------------|
| Temperature | Diode Mode data | Diode Mode data | Diode Mode data not |
| | available and | available and | available (due to |
| | Temperature check | Temperature check| failure of an FQIC |
| | not failed. | failed. | circuit or a probe |
| | | | diode). |
|-------------|--------------------|------------------|----------------------|