BIT DESCRIPTION VALUE
-------------------------------------------------------------------------------R 01 Status of ADC MUX on SC2 board True = healthy R 00 Status of ADC MUX on SC1 board True = healthy
1EFF : 301-399, 1 28-42-00Page A521 1 1 Feb 01/05 1 1 1CES 1 1EFF : 301-399, 1 28-42-00Page A522 1 1 Feb 01/05 1 1 1CES 1
R FQIC MONITORING 1 - Snapshot Word 4
R
R BIT DESCRIPTION VALUE
R -------------------------------------------------------------------------------
R 15 Indicates if channel is master or slave True = master
R 14 Indicates the ground/flight a/c status True = ground
R 13 Indicates failure status of SC2 board False = SC2 not failed
R 12 Indicates failure status of SC1 board False = SC1 not failed
R -------------------------------------------------------------------------------
R 11 Status of filtered VOS from CVOS True = valid
R 10 Status of filtered VOS from RIVOS True = valid
R 09 Status of temperature sensor RTEMPB True = valid or good
R 08 Status of temperature sensor RTEMPA True = valid or good
R -------------------------------------------------------------------------------
R 07 Status of temperature sensor LTEMPB True = valid or good
R 06 Status of temperature sensor LTEMPA True = valid or good
R 05 Ultracomp in RIX tank is failed False = not rejected
R 04 Ultracomp in CT tank is failed False = not rejected
R -------------------------------------------------------------------------------
R 03 Status of LOZ Generator on SC2 board True = valid
R 02 Status of LOZ Generator on SC1 board True = valid
R 01 Status of LOZ Driver 4 on SC2 board True = valid
R 00 Status of LOZ Driver 3 on SC2 board True = valid
R FQIC MONITORING 1 - Snapshot Word 5
R
R BIT DESCRIPTION VALUE
R -------------------------------------------------------------------------------
R 15
R 14
R 13
R 12
R -------------------------------------------------------------------------------
R 11
R 10
R 09
R 08
R -------------------------------------------------------------------------------
R 07
R 06
R 05
R 04
R -------------------------------------------------------------------------------
R 03
R 02
BIT DESCRIPTION VALUE
-------------------------------------------------------------------------------R 01 R 00 Snapshot spare Always false
1EFF : 301-399, 1 28-42-00Page A523 1 1 Feb 01/05 1 1 1CES 1 Subtask 28-42-00-740-104
S. EVENT 0D (H) : AUXI. CENTER TANK
AUXI. CENTER TANK - Snapshot Word 1
BIT TRIG DESCRIPTION VALUE -------------------------------------------------------------------------------15 C Status of diode voltage for A1TU1 True = valid 14 B Status of diode voltage for A1TU2 True = valid 13 A Status of capacitance sensor A1TU1 True = in range 12 9 Status of capacitance sensor A1TU2 True = in range -------------------------------------------------------------------------------11 8 Status of capacitance sensor A2TU2 True = valid 10 7 Status of capacitance sensor A1TU2 True = valid 09 6 Status of capacitance sensor A2TU1 True = valid 08 5 Status of capacitance sensor A1TU1 True = valid -------------------------------------------------------------------------------07 4 ACT2 pin prog acquistion status True = 1 healthy 06 3 ACT1 pin prog acquistion status True = 1 healthy 05 2 Combined status of probes A2TU1 & A2TU2 True = 1 probe valid 04 1 Combined status of probes A1TU1 & A1TU2 True = 1 probe valid -------------------------------------------------------------------------------03 | Trigger number 02 | " 01 | " 00 | "
NOTE : The TRIG references D, E, F and 0 are given in the
____
AUXI. CENTER TANK - Snapshot Word 2, bits 00 thru 03,
(see the next page).
The column identified as TRIG, and the related data,
is only given when applicable
(for snapshot words 1 and 2).
1EFF : 301-399, 1 28-42-00Page A524 1 1 May 01/05R 1 1 1CES 1
AUXI. CENTER TANK - Snapshot Word 2
BIT TRIG DESCRIPTION VALUE -------------------------------------------------------------------------------15 Tank Unit calibration high A2TU2 True = range 14 Tank Unit calibration high A2TU1 True = range 13 Tank Unit calibration high A1TU2 True = range 12 Tank Unit calibration high A1TU1 True = range -------------------------------------------------------------------------------11 Status of diode voltage for A2TU2 True = valid 10 Status of capacitance sensor A2TU2 True = in range 09 ACT2 fitted status True = ACT2 fitted 08 ACT1 fitted status True = ACT1 fitted -------------------------------------------------------------------------------07 Indicates opp 28V power supply True = 28V present 06 Indicates failure status of SC2 board False = SC2 not failed 05 Indicates failure status of SC1 board False = SC1 not failed 04 LO-Z SC2 in range DRIVER 4 True = in range -------------------------------------------------------------------------------03 0 LO-Z SC2 in range DRIVER 3 True = in range 02 F LO-Z SC2 in range DRIVER 2 True = in range 01 E LO-Z SC2 in range DRIVER 1 True = in range 00 D Indicates if channel is master or slave True = master