The column identified as TRIG, and the related data,
is only given when applicable
(for snapshot words 1 and 2).
1EFF : 301-399, 1 28-42-00Page 598 1 1 May 01/05R 1 1 1CES 1
WINGS SC2 - Snapshot Word 2
BIT TRIG DESCRIPTION VALUE -------------------------------------------------------------------------------15 Status of capacitance sensor RTU14 True = in range 14 Status of capacitance sensor RTU12 True = in range 13 Status of capacitance sensor RTU10 True = in range 12 Status of capacitance sensor RTU8 True = in range -------------------------------------------------------------------------------11 Status of capacitance sensor RTU6 True = in range 10 Status of capacitance sensor RTU4 True = in range 09 Status of capacitance sensor RUCOMP True = in range 08 Status of capacitance sensor RTU13 True = in range -------------------------------------------------------------------------------07 Status of capacitance sensor LTU11 True = in range 06 Status of capacitance sensor LTU9 True = in range 05 Status of capacitance sensor LTU7 True = in range 04 Status of capacitance sensor LTU5 True = in range -------------------------------------------------------------------------------03 0 Status of capacitance sensor LTU3 True = in range 02 F Status of capacitance sensor LDCOMPA True = in range 01 E Status of capacitance sensor RTU14 True = valid 00 D Status of capacitance sensor RTU12 True = valid
WINGS SC2 - Snapshot Word 3
BIT DESCRIPTION VALUE -------------------------------------------------------------------------------15 LO-Z SC2 in range DRIVER 2 True = in range 14 LO-Z SC2 in range DRIVER 1 True = in range 13 Status of diode voltage for RTU14 True = valid 12 Status of diode voltage for RTU12 True = valid -------------------------------------------------------------------------------11 Status of diode voltage for RTU10 True = valid 10 Status of diode voltage for RTU8 True = valid 09 Status of diode voltage for RTU6 True = valid 08 Status of diode voltage for RTU4 True = valid -------------------------------------------------------------------------------07 Status of diode voltage for RUCOMP True = valid 06 Status of diode voltage for LTU13 True = valid 05 Status of diode voltage for LTU11 True = valid 04 Status of diode voltage for LTU9 True = valid -------------------------------------------------------------------------------03 Status of diode voltage for LTU7 True = valid 02 Status of diode voltage for LTU5 True = valid
1EFF : 301-399, 1 28-42-00Page 599 1 1 May 01/05R 1 1 1CES 1
INTENTIONALLY BLANK
R 1 1 28-42-00Page A500 1 1 May 01/05 1 1 1CES 1
BIT DESCRIPTION VALUE
-------------------------------------------------------------------------------R 01 Status of diode voltage for LTU3 True = valid R 00 Status of diode voltage for LDCOMPA True = valid
1EFF : 301-399, 1 28-42-00Page A501 1 1 Feb 01/05 1 1 1CES 1 1EFF : 301-399, 1 28-42-00Page A502 1 1 Feb 01/05 1 1 1CES 1
R WINGS SC2 - Snapshot Word 4
R
R BIT DESCRIPTION VALUE
R -------------------------------------------------------------------------------
R 15 Tank Unit calibration low RUCOMP True = in range
R 14 Tank Unit calibration high RUCOMP True = in range
R 13 Tank Unit calibration low LTU13 True = in range
R 12 Tank Unit calibration high LTU13 True = in range
R -------------------------------------------------------------------------------
R 11 Tank Unit calibration low LTU11 True = in range
R 10 Tank Unit calibration high LTU11 True = in range
R 09 Tank Unit calibration low LTU9 True = in range
R 08 Tank Unit calibration high LTU9 True = in range
R -------------------------------------------------------------------------------
R 07 Tank Unit calibration low LTU7 True = in range
R 06 Tank Unit calibration high LTU7 True = in range
R 05 Tank Unit calibration low LTU5 True = in range
R 04 Tank Unit calibration high LTU5 True = in range
R -------------------------------------------------------------------------------
R 03 Tank Unit calibration low LTU3 True = in range
R 02 Tank Unit calibration high LTU3 True = in range
R 01 Tank Unit calibration low LDCOMPA True = in range
R 00 Tank Unit calibration high LDCOMPA True = in range
R WINGS SC2 - Snapshot Word 5
R
R BIT DESCRIPTION VALUE
R -------------------------------------------------------------------------------
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油5(49)