Push the line key adjacent to the LAST LEG REPORT.
3.
When the LAST LEG REPORT shows NO FAULTS:
A. Push the RETURN key two times to exit the FUEL system menus.
B. Do the Close-up, or if applicable, access other FUEL menus.
4.
When the LAST LEG REPORT shows an applicable failed LRU message:
A. Push the line key to the right of its ATA number.
B. Find the location (GRID REF) of the 1(s) shown in the TROUBLE SHOOTING data.
C. Make a record of the GRID REF of the 1(s), or use the MCDU print function to get a print-out of the TROUBLE SHOOTING data.
- on the MCDU display the FUEL mainmenu, first page, comes into view.
-
the LAST LEG REPORT page comes intoview.
-
the CFDS SYSTEM REPORT/TEST main menupage comes into view.
-
the related FUEL FLSCU/FQIC TROUBLESHOOTING page comes into view.
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-42-00Page 539 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
Access to the T/S Data From the LAST LEG REPORT (SI)
Figure 504/TASK 28-42-00-991-006
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-42-00Page 540 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
D. Go to the applicable step that
follows, and read the failure
type for the given GRID REF:
-
for the FLSCU TROUBLE
SHOOTING data refer to Para
4.H.
-
for the FQIC TROUBLE
SHOOTING data refer to Para
4.J. Tables 1 thru 6.
E. When applicable, do the
Close-up.
Subtask 28-42-00-740-080
C. Interrogation of the FUEL FLSCU/FQIC TROUBLE SHOOTING data from the
PREVIOUS LEGS REPORT
(Ref. Fig. 505/TASK 28-42-00-991-007)
(1) When the SYSTEM REPORT/TEST menu page comes into view, do this procedure:
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1.
Push the MCDU line key adjacent to the FUEL indication.
2.
Push the line key adjacent to the PREVIOUS LEGS REPORT.
3.
When the PREVIOUS LEGS REPORT shows NO FAULTS:
A. Push the RETURN key two times to exit the FUEL system menus.
B. Do the Close-up, or if applicable, access other FUEL menus.
- on the MCDU display the FUEL mainmenu, first page, comes into view.
-
the PREVIOUS LEGS REPORT page comesinto view.
-
the CFDS SYSTEM REPORT/TEST main menupage comes into view.
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-42-00Page 541 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
Access to the T/S Data From the PREVIOUS LEGS REPORT (SI)
Figure 505/TASK 28-42-00-991-007
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-42-00Page 542 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
4. When the PREVIOUS LEGS REPORT shows an applicable failed LRU message:
A. Push the line key to the right of its ATA number.
B. Find the location (GRID REF) of the 1(s) shown in the TROUBLE SHOOTING data.
C. Make a record of the GRID REF of the 1(s), or use the MCDU print function to get a print-out of the TROUBLE SHOOTING data.
D. Go to the applicable step that follows, and read the failure type for the given GRID REF:
-
for the FLSCU TROUBLE SHOOTING data refer to Para
4.H.
-
for the FQIC TROUBLE SHOOTING data refer to Para
4.J. Tables 1 thru 6.
E. When applicable, do the
Close-up.
-the related FUEL FLSCU/FQIC TROUBLESHOOTING page comes into view.
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 28-42-00Page 543 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1 Subtask 28-42-00-740-083
D. Interrogation of the FUEL CADENS (cadensicon) TROUBLE SHOOTING data from the CLASS 3 FAULTS page (Ref. Fig. 506/TASK 28-42-00-991-008)
(1) When the SYSTEM REPORT/TEST menu page comes into view, do this procedure: