TASK 23-24-00-810-811
Loss of the FWC1 Signal by the ACARS MU
1. Possible Causes
_______________
- MU-ACARS (1RB)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R AMM 23-24-00-740-003 AMM 23-24-34-000-001 Removal of the ACARS Management Unit (MU) (1RB) AMM 23-24-34-400-001 Installation of the ACARS Management Unit (MU) (1RB) ASM 23-24/02
3. Fault Confirmation
__________________
A. Test
(1) Do the BITE test of the ACARS (Ref. AMM TASK 23-24-00-740-003).
4. Fault Isolation
_______________
A. If the test gives the maintenance message FWC1 (1WW1)/ACARS MU (1RB):
- replace the MU-ACARS (1RB) (Ref. AMM TASK 23-24-34-000-001) and (Ref. AMM TASK 23-24-34-400-001).
(1) If the fault continues:
- do a check and repair the wiring from pins AB/14G and AB/14H of the ACARS MU (1RB) to the first terminal block (Ref. ASM 23-24/02).
B. Do the test given in Para. 3.
TASK 23-24-00-810-813
Loss of the DMU Signal by the ACARS MU
1. Possible Causes
_______________
- MU-ACARS (1RB)
- DMU (1TV)
- wiring
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
R AMM 23-24-00-740-003 AMM 23-24-34-000-001 Removal of the ACARS Management Unit (MU) (1RB) AMM 23-24-34-400-001 Installation of the ACARS Management Unit (MU) (1RB) AMM 31-36-34-000-001 Removal of the Data Management Unit (DMU) (1TV) AMM 31-36-34-400-001 Installation of the Data Management Unit (DMU) (1TV) ASM 23-24/02
3. Fault Confirmation
__________________
A. Test
(1) Do the BITE test of the ACARS (Ref. AMM TASK 23-24-00-740-003).
4. Fault Isolation
_______________
A. If the test gives the maintenance message DMU (1TV)/ACARS MU (1RB):
- replace the MU-ACARS (1RB) (Ref. AMM TASK 23-24-34-000-001) and (Ref. AMM TASK 23-24-34-400-001).
(1) If the fault continues:
- replace the DMU (1TV) (Ref. AMM TASK 31-36-34-000-001) and (Ref. AMM TASK 31-36-34-400-001).
(2) If the fault continues:
- do a check and repair the wiring from pins AB/11J and AB/11K of the DMU (1TV) to pins AB/7J and AB/7K of the ACARS MU (1RB) (Ref. ASM 23-24/02).
B. Do the test given in Para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-105, ∞∞23-24-00∞∞∞∞∞∞∞∞∞∞Page 211
May 01/05 CES
TASK 23-24-00-810-814
Failure of the ACARS MU
1. Possible Causes
_______________
- MU-ACARS (1RB)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-24-00-710-001 Operational Test of the ACARS
AMM 23-24-34-000-001 Removal of the ACARS Management Unit (MU) (1RB)
AMM 23-24-34-400-001 Installation of the ACARS Management Unit (MU) (1RB)
3. Fault Confirmation
__________________
A. Test
(1) Do the operational test of the ACARS (Ref. AMM TASK 23-24-00-710-001).
4. Fault Isolation
_______________
A. If the test confirms the fault:
- replace the MU-ACARS (1RB) (Ref. AMM TASK 23-24-34-000-001) and (Ref. AMM TASK 23-24-34-400-001).
TASK 23-24-00-810-815
Loss of the ACARS-MU Data Transmission
1. Possible Causes
_______________
- MU-ACARS (1RB)
- XCVR-VHF, 3 (1RC3)
- wiring from the ACARS MU (1RB) to the VHF3 transceiver (1RC3)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-12-33-000-001 Removal of the VHF Transceiver (1RC1, 1RC2, 1RC3) AMM 23-12-33-400-001 Installation of the VHF Transceiver (1RC1, 1RC2,
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 COMMUNICATIONS 通讯1(96)