 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞23-13-00∞∞∞∞∞∞∞∞∞∞Page 259
 May 01/05 CES


R **ON A/C 062-099, 106-149, 151-199, 201-299, 301-399, 401-499,

 A. If the test gives the maintenance message RMP1(1RG1)/RMP2(1RG2):
 - replace the RMP-COM/NAV FREQ SEL, 2 (1RG2) (Ref. AMM TASK 23-13-13-000-001) and (Ref. AMM TASK 23-13-13-400-001).
 (1) If the fault continues:
 - do a check and repair the wiring of the DIALOGUE INPUT signal, (from the RMP 2 (1RG2) pins A/<Z, AA to the first terminal block) (Ref. ASM 23-13/01).
 **ON A/C ALL
 B. Do the test given in Para. 3.B.

 TASK 23-13-00-810-843


 Action on Double Arrow Pushbutton Switch of the RMP 1 Inoperative
 1. Possible Causes
_______________
 - RMP-COM/NAV FREQ SEL, 1 (1RG1)
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-13-00-710-001 Operational Test of the Radio Management AMM 23-13-13-000-001 Removal of the Radio Management Panel (CRMP) (1RG1, 1RG2, 1RG3) AMM 23-13-13-400-001 Installation of the Radio Management Panel (CRMP) (1RG1, 1RG2, 1RG3)
 3. Fault Confirmation
__________________
 A. Test Do the operational test of the radio management (Ref. AMM TASK 23-13-00-710-001).
 NOTE : Do this test for the RMP 1 only.
____
 4. Fault Isolation
_______________
 A. If the frequency indication does not go from a display window to the other on the RMP 1:
 - replace the RMP-COM/NAV FREQ SEL, 1 (1RG1) (Ref. AMM TASK 23-13-13-000-001) and (Ref. AMM TASK 23-13-13-400-001).
 B. Do the test given in Para. 3.


 TASK 23-13-00-810-844 Action on Double Arrow Pushbutton Switch of the RMP 2 Inoperative
 1. Possible Causes
_______________
 - RMP-COM/NAV FREQ SEL, 2 (1RG2)
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-13-00-710-001 Operational Test of the Radio Management AMM 23-13-13-000-001 Removal of the Radio Management Panel (CRMP) (1RG1, 1RG2, 1RG3) AMM 23-13-13-400-001 Installation of the Radio Management Panel (CRMP) (1RG1, 1RG2, 1RG3)
 3. Fault Confirmation
__________________
 A. Test Do the operational test of the radio management (Ref. AMM TASK 23-13-00-710-001).
 NOTE : Do this test for the RMP 2 only.
____
 4. Fault Isolation
_______________
 A. If the frequency indication does not go from a display window to the other on the RMP 2:
 - replace the RMP-COM/NAV FREQ SEL, 2 (1RG2) (Ref. AMM TASK 23-13-13-000-001) and (Ref. AMM TASK 23-13-13-400-001).
 B. Do the test given in Para. 3.


 TASK 23-13-00-810-845 Action on Double Arrow Pushbutton Switch of the RMP 3 Inoperative
 1. Possible Causes
_______________
 - RMP-COM FREQ SEL, 3 (1RG3)
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 23-13-00-710-001 Operational Test of the Radio Management AMM 23-13-13-000-001 Removal of the Radio Management Panel (CRMP) (1RG1, 1RG2, 1RG3) AMM 23-13-13-400-001 Installation of the Radio Management Panel (CRMP) (1RG1, 1RG2, 1RG3)
 3. Fault Confirmation
__________________
 A. Test Do the operational test of the radio management (Ref. AMM TASK 23-13-00-710-001).
 NOTE : Do this test for the RMP 3 only.
____
 4. Fault Isolation
_______________
 A. If the frequency indication does not go from a display window to the other on the RMP 3:
 - replace the RMP-COM FREQ SEL, 3 (1RG3) (Ref. AMM TASK 23-13-13-000-001) and (Ref. AMM TASK 23-13-13-400-001).
 B. Do the test given in Para. 3.


 TASK 23-13-00-810-846
 Loss of the RMP 1 Data on the Bus 2 (CFDIU Source)
 1. Possible Causes
_______________
 - RMP-COM/NAV FREQ SEL, 1 (1RG1)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 